Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Yamamoto, Kazami; Kinsho, Michikazu; Hayashi, Naoki; Saha, P. K.; Tamura, Fumihiko; Yamamoto, Masanobu; Tani, Norio; Takayanagi, Tomohiro; Kamiya, Junichiro; Shobuda, Yoshihiro; et al.
Journal of Nuclear Science and Technology, 59(9), p.1174 - 1205, 2022/09
Times Cited Count:6 Percentile:84.97(Nuclear Science & Technology)In the Japan Proton Accelerator Research Complex, the purpose of the 3 GeV rapid cycling synchrotron (RCS) is to accelerate a 1 MW, high-intensity proton beam. To achieve beam operation at a repetition rate of 25 Hz at high intensities, the RCS was elaborately designed. After starting the RCS operation, we carefully verified the validity of its design and made certain improvements to establish a reliable operation at higher power as possible. Consequently, we demonstrated beam operation at a high power, namely, 1 MW. We then summarized the design, actual performance, and improvements of the RCS to achieve a 1 MW beam.
Nagai, Takayuki; Okamoto, Yoshihiro; Shiwaku, Hideaki; Inose, Takehiko*; Sato, Seiichi*; Hatakeyama, Kiyoshi*; Hirono, Kazuya*; Homma, Masanobu*; Kobayashi, Hiromi*; Takahashi, Tomoe*; et al.
JAEA-Research 2018-007, 87 Pages, 2018/11
To select the chemical composition of a glass frit which can increase the waste content, the simulated waste glass samples prepared from a borosilicate glass frit including vanadium (V) were investigated by using Laser Ablation (LA) ICP-AES analysis, Raman spectrometry, and synchrotron XAFS measurement in this study on foundation business of the Agency for Natural Resources and Energy.
Tomizawa, Hiromitsu*; Sato, Takahiro*; Ogawa, Kanade*; Togawa, Kazuaki*; Tanaka, Takatsugu*; Hara, Toru*; Yabashi, Makina*; Tanaka, Hitoshi*; Ishikawa, Tetsuya*; Togashi, Tadashi*; et al.
High Power Laser Science and Engineering, 3, p.e14_1 - e14_10, 2015/04
Times Cited Count:6 Percentile:34.43(Optics)no abstracts in English
Komori, Yukiko*; Yokokita, Takuya*; Kasamatsu, Yoshitaka*; Haba, Hiromitsu*; Toyoshima, Atsushi; Toyomura, Keigo*; Nakamura, Kohei*; Kanaya, Jumpei*; Huang, M.*; Kudo, Yuki*; et al.
Journal of Radioanalytical and Nuclear Chemistry, 303(2), p.1385 - 1388, 2015/02
Times Cited Count:2 Percentile:17.57(Chemistry, Analytical)We studied solid-liquid extraction behavior of carrier-free Mo and W radiotracers onto an Aliquat 336-loaded resin from HCl solutions toward extraction chromatography experiments of element 106, seaborgium(Sg). Distribution coefficients () of Mo and W on the resin were determined as a function of HCl concentration by a batch method. On-line extraction chromatography of Mo and W was also carried out in 2-8 M HCl solutions with an automated rapid chemistry apparatus. The order of extraction probability from 2 to 8 M HCl was MoW, which reflected the order of the values in the batch experiment.
Takahashi, Hiroki; Maebara, Sunao; Kojima, Toshiyuki; Narita, Takahiro; Tsutsumi, Kazuyoshi; Sakaki, Hironao; Suzuki, Hiromitsu; Sugimoto, Masayoshi
Fusion Engineering and Design, 89(9-10), p.2066 - 2070, 2014/10
Times Cited Count:0 Percentile:0.01(Nuclear Science & Technology)Takahashi, Ryuichi*; Ishimaru, Yasuhiro*; Shimo, H.*; Bashir, K.*; Senoura, Takeshi*; Sugimoto, Kazuhiko*; Ono, Kazuko*; Suzui, Nobuo; Kawachi, Naoki; Ishii, Satomi; et al.
PLOS ONE (Internet), 9(6), p.e98816_1 - e98816_7, 2014/06
Times Cited Count:51 Percentile:86.7(Multidisciplinary Sciences)Maebara, Sunao; Antonio, P.*; Ichikawa, Masahiro; Takahashi, Hiroki; Suzuki, Hiromitsu; Sugimoto, Masayoshi
Proceedings of 10th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.561 - 563, 2014/06
no abstracts in English
Takahashi, Hiroki; Kojima, Toshiyuki; Narita, Takahiro; Maebara, Sunao; Sakaki, Hironao; Suzuki, Hiromitsu
Proceedings of 10th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.724 - 727, 2014/06
no abstracts in English
Takahashi, Hiroki; Maebara, Sunao; Sakaki, Hironao; Ichikawa, Masahiro; Suzuki, Hiromitsu; Sugimoto, Masayoshi
Progress in Nuclear Science and Technology (Internet), 4, p.261 - 263, 2014/04
An development of accelerator-based neutron irradiation facility is planning to develop materials for a demonstration fusion reactor. To obtain a 14 MeV neutron energy using the neutron-generating D-Li stripping reaction, an injection into liquid lithium flow by a 40 MeV deuteron beam is employed in IFMIF design concept. In the acceleration of deuteron beam, the activation due to the beam loss is critical issue. The activation analyses for the air in an accelerator vault are carried out by PHITS code and DCHAIN code using the experimental data for deuteron induced thick target neutron yield at 5 MeV and 9 MeV for source term.
Maebara, Sunao; Palmieri, A.*; Mereu, P.*; Ichikawa, Masahiro; Takahashi, Hiroki; Comunian, M.*; Suzuki, Hiromitsu; Pisent, A.*; Sugimoto, Masayoshi
Fusion Engineering and Design, 88(9-10), p.2740 - 2743, 2013/10
Times Cited Count:3 Percentile:25.73(Nuclear Science & Technology)Takahashi, Hiroki; Maebara, Sunao; Sakaki, Hironao; Suzuki, Hiromitsu; Sugimoto, Masayoshi
JAEA-Conf 2013-002, p.109 - 112, 2013/10
Sato, Takahiro*; Iwasaki, Atsushi*; Owada, Shigeki*; Yamanouchi, Kaoru*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Togashi, Tadashi*; Fukami, Kenji*; et al.
Journal of Physics B; Atomic, Molecular and Optical Physics, 46(16), p.164006_1 - 164006_6, 2013/08
Times Cited Count:3 Percentile:19.06(Optics)By introducing 13th- (61.7 nm) and 15th-order harmonics (53.4 nm) of femtosecond laser pulses at 800 nm into an undulator of SCSS (SPring-8 Compact SASE Source) test accelerator at RIKEN, these harmonic pulses were amplified by a factor of more than 10 with a high contrast ratio through the interaction between accelerated electron bunches and the harmonic pulses. From numerical simulations of the amplification processes of high-order harmonic pulses in the undulator, optimum conditions of the electron bunch duration interacting with the high-order harmonic pulses were investigated for generating full-coherent and intense pulses in the extreme ultraviolet wavelength region.
Minami, Ryutaro*; Kariya, Tsuyoshi*; Imai, Tsuyoshi*; Numakura, Tomoharu*; Endo, Yoichi*; Nakabayashi, Hidetaka*; Eguchi, Taku*; Shimozuma, Takashi*; Kubo, Shin*; Yoshimura, Yasuo*; et al.
Nuclear Fusion, 53(6), p.063003_1 - 063003_7, 2013/06
Minami, Ryutaro*; Kariya, Tsuyoshi*; Imai, Tsuyoshi*; Numakura, Tomoharu*; Endo, Yoichi*; Nakabayashi, Hidetaka*; Eguchi, Taku*; Shimozuma, Takashi*; Kubo, Shin*; Yoshimura, Yasuo*; et al.
Nuclear Fusion, 53(6), p.063003_1 - 063003_7, 2013/06
Times Cited Count:12 Percentile:47.42(Physics, Fluids & Plasmas)Ogawa, Kanade*; Sato, Takahiro*; Matsubara, Shinichi*; Okayasu, Yuichi*; Togashi, Tadashi*; Watanabe, Takahiro*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; et al.
Proceedings of 10th Conference on Lasers and Electro-Optics Pacific Rim and 18th OptoElectronics and Communications Conference and Photonics in Switching 2013 (CLEO-PR & OECC/PS 2013) (USB Flash Drive), 2 Pages, 2013/06
no abstracts in English
Ito, Kazuhiro; Tanabe, Hiromi; Kaneko, Yoshihisa; Kagota, Eiichi; Takahashi, Yasuo
Proceedings of 2013 International Congress on Advances in Nuclear Power Plants (ICAPP 2013) (USB Flash Drive), 10 Pages, 2013/04
The Monju is equipped with two types of hydrogen-meters to detect water leakage in steam generators. Since they are so highly-sensitive as to detect minor water leak from a steam generator tube, they sometimes detect hydrogen concentration increases at plant operational condition changes such as start-up without any water leak. No water leak was experienced during one year operation of the Startup Test up to 40% in 1995, although hydrogen concentration sometimes increased at plant operational condition changes. The H behavior of Monju IHTS during the previous Startup Test was examined and the following knowledge was obtained: The in-sodium H behaves in parallel with the IHTS sodium temperature. In-cover-gas H behavior is more complicated and sensitive to plant operational condition changes such as plant load changes than the in-sodium one. Both types of H-meters underwent a certain degree of zero level drift during one year operation.
Togashi, Tadashi*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Sato, Takahiro*; Iwasaki, Atsushi*; Owada, Shigeki*; Yamanouchi, Kaoru*; Hara, Toru*; et al.
Proceedings of Ultrafast Optics IX (CD-ROM), 2 Pages, 2013/03
We have demonstrated free-electron laser radiation seeded by high-order harmonics in the extreme-ultraviolet region. Strong enhancement of the radiation intensity by a factor of 104 was observed with timing control of an electro-optical sampling technique.
Okayasu, Yuichi*; Tomizawa, Hiromitsu*; Matsubara, Shinichi*; Sato, Takahiro*; Ogawa, Kanade*; Togashi, Tadashi*; Takahashi, Eiji*; Minamide, Hiroaki*; Matsukawa, Ken*; Aoyama, Makoto; et al.
Proceedings of 1st International Beam Instrumentation Conference (IBIC 2012) (Internet), 5 Pages, 2012/10
no abstracts in English
Iwasaki, Atsushi*; Sato, Takahiro*; Owada, Shigeki*; Togashi, Tadashi*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Matsubara, Shinichi*; Okayasu, Yuichi*; et al.
Proceedings of International Conference on Ultrafast Phenomena 2012 (UP 2012) (Internet), 3 Pages, 2012/07
Times Cited Count:0 Percentile:0.03(Physics, Multidisciplinary)no abstracts in English
Togashi, Tadashi*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Sato, Takahiro*; Iwasaki, Atsushi*; Owada, Shigeki*; Yamanouchi, Kaoru*; Hara, Toru*; et al.
Proceedings of 11th International School and Symposium on Synchrotron Radiation in Natural Science (ISSRNS 2012), p.1 - 21, 2012/05
The 13th harmonic of a Ti:sapphire laser has been significantly amplified with the SCSS test accelerator. The temporal and spatial overlap of the electron beam and the high harmonic radiation were precisely tuned for achieving the seeded free electron laser operation. With numerical simulation the present HH-seeded FEL scheme could readily be applied to the wavelength region down to 10 nm.