Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Kobayashi, Fuminori; Kamiya, Junichiro; Takahashi, Hiroki; Suzuki, Yasuo*; Tasaki, Ryuta*
JAEA-Technology 2024-007, 28 Pages, 2024/07
In J-PARC LINAC, the vacuum system is in place to maintain an ultra-high vacuum in the beam transport line (LINAC to 3GeV RCS beam transportation line: L3BT) between the LINAC to the 3GeV synchrotron. The vacuum system is installed in the LINAC and L3BT buildings and consists of vacuum pumps, vacuum gauges, beam line gate valves (BLGVs), and other vacuum. In existing vacuum systems, vacuum equipment is controlled independently for each area, and vacuum equipment can be operated regardless of the status of adjacent areas. This makes it impossible to eliminate erroneous operation due to human error. In addition, when a vacuum deterioration occurs in the beam transport line, the vacuum deterioration ILK signal is transmitted to the BLGV relay unit via the MPS transmission signal, which causes the BLGVs to be forcibly closed. Because the ILK signal transmission range extends to all BLGVs in the L3BT, however, BLGVs in areas unaffected by vacuum deterioration are also forced to close. This could cause problems such as unnecessary open/close operations leading to more frequent maintenance cycles of the BLGVs. In addition, since the BLGV is operated using the MPS signal path, maintenance of the vacuum control system requires work involving the MPS signal path, making it difficult to maintain the vacuum control system alone and making the work complicated. To solve these problems, it is necessary to improve maintainability by separating the signal paths and automatically controlling BLGV separately. Therefore, the vacuum control system was modified and constructed with the aim of realizing a control system that takes into account the safety and efficient maintenance and operation of the L3BT vacuum system. This report summarizes the development and use of the L3BT vacuum system control system.
Ito, Fumiaki*; Lee, J.; Hironaka, Kota; Takahashi, Tone; Suzuki, Satoshi*; Mochimaru, Takanori*; Hori, Junichi*; Terada, Kazushi*; Koizumi, Mitsuo
Nuclear Instruments and Methods in Physics Research A, 1064, p.169465_1 - 169465_9, 2024/07
Times Cited Count:0 Percentile:0.00(Instruments & Instrumentation)Lee, J.; Ito, Fumiaki*; Hironaka, Kota; Takahashi, Tone; Suzuki, Satoshi*; Koizumi, Mitsuo; Hori, Junichi*; Terada, Kazushi*
Dai-43-Kai Nihon Kaku Busshitsu Kanri Gakkai Nenji Taikai Kaigi Rombunshu (Internet), 4 Pages, 2022/11
no abstracts in English
Yamamoto, Kazami; Kinsho, Michikazu; Hayashi, Naoki; Saha, P. K.; Tamura, Fumihiko; Yamamoto, Masanobu; Tani, Norio; Takayanagi, Tomohiro; Kamiya, Junichiro; Shobuda, Yoshihiro; et al.
Journal of Nuclear Science and Technology, 59(9), p.1174 - 1205, 2022/09
Times Cited Count:7 Percentile:72.25(Nuclear Science & Technology)In the Japan Proton Accelerator Research Complex, the purpose of the 3 GeV rapid cycling synchrotron (RCS) is to accelerate a 1 MW, high-intensity proton beam. To achieve beam operation at a repetition rate of 25 Hz at high intensities, the RCS was elaborately designed. After starting the RCS operation, we carefully verified the validity of its design and made certain improvements to establish a reliable operation at higher power as possible. Consequently, we demonstrated beam operation at a high power, namely, 1 MW. We then summarized the design, actual performance, and improvements of the RCS to achieve a 1 MW beam.
Lee, J.; Hironaka, Kota; Ito, Fumiaki*; Takahashi, Tone; Koizumi, Mitsuo; Hori, Junichi*; Terada, Kazushi*
KURNS Progress Report 2021, P. 97, 2022/07
no abstracts in English
Ito, Fumiaki*; Lee, J.; Hironaka, Kota; Takahashi, Tone; Suzuki, Satoshi*; Hori, Junichi*; Terada, Kazushi*; Koizumi, Mitsuo
KURNS Progress Report 2020, P. 98, 2021/08
A compact Nuclear Resonance Transmission Analysis (NRTA) system using a Laser Driven Neutron Source (LDNS) has been developed as a part of the development of nuclear non-proliferation technology supported by the MEXT. In NRTA, the neutron energy emitted from a pulsed neutron source is measured using the time-of-flight (TOF) method. LDNS is of interest because of its short pulse width, which is necessary for accurate TOF measurements over short flight distances. In the short-distance TOF measurement, there will be a large gamma-ray background event due to the coincidence of the timing of the arrival of 2.2 MeV gamma-rays due to neutron capture on hydrogen in the moderator and the timing of the arrival of neutrons around the resonance energy. Since the LDNS is still under development, the neutron flux is not sufficient and it is desirable to use a detector with high detection efficiency. For these reasons, we have developed a detector with low efficiency to gamma-rays and high efficiency to neutrons (multilayer neutron detector). As one of the results of this year's experiments, we confirmed that the multilayer neutron detector have low sensitivity to gamma-rays.
Okudaira, Takuya; Ueda, Yuki; Hiroi, Kosuke; Motokawa, Ryuhei; Inamura, Yasuhiro; Takata, Shinichi; Oku, Takayuki; Suzuki, Junichi*; Takahashi, Shingo*; Endo, Hitoshi*; et al.
Journal of Applied Crystallography, 54(2), p.548 - 556, 2021/04
Times Cited Count:4 Percentile:48.63(Chemistry, Multidisciplinary)Neutron polarization analysis (NPA) for small-angle neutron scattering (SANS) experiments using a pulsed neutron source was successfully achieved by applying a He spin filter as a spin analyzer for the scattered neutrons. The He spin filter covers a sufficient solid angle for performing SANS experiments, and the relaxation time of the He polarization is sufficient for continuous use over a few days, thus reaching the typical duration required for a complete set of SANS experiments. Although accurate evaluation of the incoherent neutron scattering, which is predominantly attributable to hydrogen atoms in samples, is practically difficult using calculations based on the sample elemental composition, the developed NPA approach with consideration of the influence of multiple neutron scattering enabled reliable decomposition of the SANS intensity distribution into the coherent and incoherent scattering components. To date, NPA has not been well established as a standard technique for SANS experiments at pulsed neutron sources. This work is anticipated to greatly contribute to the accurate determination of the coherent neutron scattering component for scatterers in various types of organic sample systems in SANS experiments at J-PARC.
Kamiya, Junichiro; Kotoku, Hirofumi; Hikichi, Yusuke*; Takahashi, Hiroki; Yamamoto, Kazami; Kinsho, Michikazu; Wada, Kaoru*
JPS Conference Proceedings (Internet), 33, p.011023_1 - 011023_6, 2021/03
The vacuum system is the key for the stable high power beam operation in J-PARC 3 GeV rapid cycling synchrotron (RCS), because the gas molecules in the beam line make the beam loss due to the scattering. The more than 10 years operation of the RCS vacuum system showed that the ultra-high vacuum (UHV) has been stably maintained by the several developments. The challenges for lower beam line pressure will exist in a future operation with higher beam power. For such challenge, a TMP with a rotor of titanium alloy, which have much higher mechanical strength than aluminum allow for the normal rotter, has been developed. Overcoming the difficulties of the machining performance of the titanium alloy rotor was successfully manufactured. We will report the summary of the 10 years operation of the RCS vacuum system and the incoming developments towards the XHV.
Okudaira, Takuya; Oku, Takayuki; Ino, Takashi*; Hayashida, Hirotoshi*; Kira, Hiroshi*; Sakai, Kenji; Hiroi, Kosuke; Takahashi, Shingo*; Aizawa, Kazuya; Endo, Hitoshi*; et al.
Nuclear Instruments and Methods in Physics Research A, 977, p.164301_1 - 164301_8, 2020/10
Times Cited Count:18 Percentile:89.70(Instruments & Instrumentation)Kimura, Atsushi; Nakamura, Shoji; Terada, Kazushi*; Nakao, Taro*; Mizuyama, Kazuhito*; Iwamoto, Nobuyuki; Iwamoto, Osamu; Harada, Hideo; Katabuchi, Tatsuya*; Igashira, Masayuki*; et al.
Journal of Nuclear Science and Technology, 56(6), p.479 - 492, 2019/06
Times Cited Count:15 Percentile:82.75(Nuclear Science & Technology)Terada, Kazushi*; Kimura, Atsushi; Nakao, Taro*; Nakamura, Shoji; Mizuyama, Kazuhito*; Iwamoto, Nobuyuki; Iwamoto, Osamu; Harada, Hideo; Katabuchi, Tatsuya*; Igashira, Masayuki*; et al.
Journal of Nuclear Science and Technology, 55(10), p.1198 - 1211, 2018/10
Times Cited Count:18 Percentile:85.57(Nuclear Science & Technology)Kitatani, Fumito; Tsuchiya, Harufumi; Toh, Yosuke; Hori, Junichi*; Sano, Tadafumi*; Takahashi, Yoshiyuki*; Nakajima, Ken*
KURRI Progress Report 2017, P. 99, 2018/08
Okabe, Kota; Yamamoto, Kazami; Kamiya, Junichiro; Takayanagi, Tomohiro; Yamamoto, Masanobu; Yoshimoto, Masahiro; Takeda, Osamu*; Horino, Koki*; Ueno, Tomoaki*; Yanagibashi, Toru*; et al.
Proceedings of 14th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.853 - 857, 2017/12
The most important issue is to reduce the uncontrolled beam loss in the high intensity hadron accelerator such as J-PARC proton accelerators. The J-PARC 3 GeV Synchrotron (RCS) has a collimator system which narrows a high intensity beam in the RCS. After startup of RCS in 2007, the collimator system of the RCS worked well. However, in April 2016, vacuum leakage at the collimator system occurred during the maintenance operation. To investigate a cause of the failure, we took apart iron shields of the collimator reducing exposed dose of operators. As a result of inspection, we succeeded to identify the cause of the vacuum leakage failure. In this presentation, we report the failure investigation of the beam collimator system in the RCS.
Harada, Hideo; Iwamoto, Osamu; Iwamoto, Nobuyuki; Kimura, Atsushi; Terada, Kazushi; Nakao, Taro; Nakamura, Shoji; Mizuyama, Kazuhito; Igashira, Masayuki*; Katabuchi, Tatsuya*; et al.
EPJ Web of Conferences, 146, p.11001_1 - 11001_6, 2017/09
Times Cited Count:2 Percentile:76.51(Nuclear Science & Technology)Sano, Tadafumi*; Hori, Junichi*; Takahashi, Yoshiyuki*; Yashima, Hiroshi*; Lee, J.*; Harada, Hideo
EPJ Web of Conferences, 146, p.03031_1 - 03031_3, 2017/09
Times Cited Count:6 Percentile:92.78(Nuclear Science & Technology)Nakamura, Shoji; Terada, Kazushi; Takahashi, Yoshiyuki*; Sano, Tadafumi*; Hori, Junichi*
KURRI Progress Report 2015, P. 69, 2016/08
Neutron capture cross section measurements has been conducted for Minor Actinides (MAs) under the research project entitled by "Research and development for Accuracy Improvement of neutron nuclear data on Minor ACtinides (AIMAC)". The present work selected two americium isotopes, Am and Am, were selected, and measurements were carried out by an activation method with neutron sources at KURRI-Linac. It was found that the neutron flux at the target positon was of the order of 10 (n/cms). The reaction rates of Am and Am were obtained by - and -ray measurements of the irradiated Am samples.
Nakamura, Shoji; Terada, Kazushi; Shibahara, Yuji*; Uehara, Akihiro*; Fujii, Toshiyuki*; Sano, Tadafumi*; Takahashi, Yoshiyuki*; Hori, Junichi*
KURRI Progress Report 2015, P. 67, 2016/08
The activation measurements of Np-237 were performed with neutron sources at KURRI-Linac. It was found that activation measurements supported the evaluated cross-section data of JENDL-4.0.
Takahashi, Yoshiyuki*; Hori, Junichi*; Sano, Tadafumi*; Yagi, Takahiro*; Yashima, Hiroshi*; Pyeon, C. H.*; Nakamura, Shoji; Harada, Hideo
Proceedings of International Conference on the Physics of Reactors; Unifying Theory and Experiments in the 21st Century (PHYSOR 2016) (USB Flash Drive), p.645 - 652, 2016/05
For the reduction of radioactive toxicities, feasibility study of nuclear transmutation of minor actinides (MAs) and long-lived fission products (LLFPs) by utilizing innovative nuclear reactor system (i.e. fast breeder reactors and accelerator-driven systems) has been actively conducted. To design these nuclear reactor systems, the accurate nuclear data are required. Therefore, to obtain more accurate nuclear data, the project entitled as "Research and development for Accuracy Improvement of neutron nuclear data on Minor ACtinides(AIMAC)" has been started as one of the "Innovative Nuclear Research and Development Program". In a part of this project, the nuclear data of MAs are verified in the variable neutron spectra field at Kyoto University Research Reactor Institute-LINear ACcelerator (KURRI-LINAC) and Kyoto University Critical Assembly (KUCA). And the differential TOF data is cross-checked with an integral data for the validation of Np, Am, and Am. In this summary, the results of reaction rate of neutron capture cross section of Np are reported as an example in the study.
Takahashi, Ryo*; Matsuo, Mamoru; Ono, Masao; Harii, Kazuya; Chudo, Hiroyuki; Okayasu, Satoru; Ieda, Junichi; Takahashi, Saburo*; Maekawa, Sadamichi; Saito, Eiji
Nature Physics, 12, p.52 - 56, 2016/01
Times Cited Count:114 Percentile:96.28(Physics, Multidisciplinary)Ono, Masao; Chudo, Hiroyuki; Harii, Kazuya; Okayasu, Satoru; Matsuo, Mamoru; Ieda, Junichi; Takahashi, Ryo*; Maekawa, Sadamichi; Saito, Eiji
Physical Review B, 92(17), p.174424_1 - 174424_4, 2015/11
Times Cited Count:31 Percentile:75.11(Materials Science, Multidisciplinary)