Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 84

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Development of nondestructive elemental analysis system for Hayabusa2 samples using muonic X-rays

Osawa, Takahito; Nagasawa, Shunsaku*; Ninomiya, Kazuhiko*; Takahashi, Tadayuki*; Nakamura, Tomoki*; Wada, Taiga*; Taniguchi, Akihiro*; Umegaki, Izumi*; Kubo, Kenya*; Terada, Kentaro*; et al.

ACS Earth and Space Chemistry (Internet), 7(4), p.699 - 711, 2023/04

 Times Cited Count:4 Percentile:92.07(Chemistry, Multidisciplinary)

The concentrations of carbon and other major elements in asteroid samples provide very important information on the birth of life on the Earth and the solar-system evolution. Elemental analysis using muonic X-rays is one of the best analytical methods to determine the elemental composition of solid materials, and notably, is the only method to determine the concentration of light elements in bulk samples in a non-destructive manner. We developed a new analysis system using muonic X-rays to measure the concentrations of carbon and other major elements in precious and expectedly tiny samples recovered from the asteroid Ryugu by spacecraft Hayabusa2. Here we report the development process of the system in 4 stages and their system configurations, The analysis system is composed of a stainless-steel analysis chamber, an acrylic glove box for manipulating asteroid samples in a clean environment, and Ge semiconductor detectors arranged to surround the analysis chamber. The performance of the analysis system, including the background level, which is crucial for the measurement, was greatly improved from the first stage to the later ones. Our feasibility study showed that the latest model of our muonic X-ray analysis system is capable of determining the carbon concentration in Hayabusa2's sample model with an uncertainty of less than 10 percent in a 6-day measurement.

Journal Articles

Composite with a glassy nonporous coordination polymer enhances gas adsorption selectivity

Zheng, X.*; Kato, Masaru*; Uemura, Yohei*; Matsumura, Daiju; Yagi, Ichizo*; Takahashi, Kiyonori*; Noro, Shinichiro*; Nakamura, Takayoshi*

Inorganic Chemistry, 62(3), p.1257 - 1263, 2023/01

 Times Cited Count:1 Percentile:52.7(Chemistry, Inorganic & Nuclear)

Journal Articles

Design and actual performance of J-PARC 3 GeV rapid cycling synchrotron for high-intensity operation

Yamamoto, Kazami; Kinsho, Michikazu; Hayashi, Naoki; Saha, P. K.; Tamura, Fumihiko; Yamamoto, Masanobu; Tani, Norio; Takayanagi, Tomohiro; Kamiya, Junichiro; Shobuda, Yoshihiro; et al.

Journal of Nuclear Science and Technology, 59(9), p.1174 - 1205, 2022/09

 Times Cited Count:5 Percentile:87.42(Nuclear Science & Technology)

In the Japan Proton Accelerator Research Complex, the purpose of the 3 GeV rapid cycling synchrotron (RCS) is to accelerate a 1 MW, high-intensity proton beam. To achieve beam operation at a repetition rate of 25 Hz at high intensities, the RCS was elaborately designed. After starting the RCS operation, we carefully verified the validity of its design and made certain improvements to establish a reliable operation at higher power as possible. Consequently, we demonstrated beam operation at a high power, namely, 1 MW. We then summarized the design, actual performance, and improvements of the RCS to achieve a 1 MW beam.

Journal Articles

Dynamical response of transition-edge sensor microcalorimeters to a pulsed charged-particle beam

Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I.-H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.

IEEE Transactions on Applied Superconductivity, 31(5), p.2101704_1 - 2101704_4, 2021/08

 Times Cited Count:1 Percentile:10.62(Engineering, Electrical & Electronic)

A superconducting transition-edge sensor (TES) microcalorimeter is an ideal X-ray detector for experiments at accelerator facilities because of good energy resolution and high efficiency. To study the performance of the TES detector with a high-intensity pulsed charged-particle beam, we measured X-ray spectra with a pulsed muon beam at the Japan Proton Accelerator Research Complex (J-PARC) in Japan. We found substantial temporal shifts of the X-ray energy correlated with the arrival time of the pulsed muon beam, which was reasonably explained by pulse pileup due to the incidence of energetic particles from the initial pulsed beam.

Journal Articles

Deexcitation dynamics of muonic atoms revealed by high-precision spectroscopy of electronic $$K$$ X rays

Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I. H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.

Physical Review Letters, 127(5), p.053001_1 - 053001_7, 2021/07

 Times Cited Count:15 Percentile:80.44(Physics, Multidisciplinary)

We observed electronic $$K$$X rays emitted from muonic iron atoms using a superconducting transition-edge-type sensor microcalorimeter. The energy resolution of 5.2 eV in FWHM allowed us to observe the asymmetric broad profile of the electronic characteristic $$K$$$$alpha$$ and $$K$$$$beta$$ X rays together with the hypersatellite $$K$$$$alpha$$ X rays around 6 keV. This signature reflects the time-dependent screening of the nuclear charge by the negative muon and the $$L$$-shell electrons, accompanied by electron side-feeding. Assisted by a simulation, this data clearly reveals the electronic $$K$$- and $$L$$-shell hole production and their temporal evolution during the muon cascade process.

Journal Articles

$$omega N$$ scattering length from $$omega$$ photoproduction on the proton near the reaction threshold

Ishikawa, Takatsugu*; Fujimura, Hisako*; Fukasawa, Hiroshi*; Hashimoto, Ryo*; He, Q.*; Honda, Yuki*; Hosaka, Atsushi; Iwata, Takahiro*; Kaida, Shun*; Kasagi, Jirota*; et al.

Physical Review C, 101(5), p.052201_1 - 052201_6, 2020/05

 Times Cited Count:4 Percentile:44.35(Physics, Nuclear)

Journal Articles

Development of a control system at a 3 MeV linac in J-PARC

Sawabe, Yuki*; Ishiyama, Tatsuya; Takahashi, Daisuke; Kato, Yuko; Suzuki, Takahiro*; Hirano, Koichiro; Takei, Hayanori; Meigo, Shinichiro; Kikuzawa, Nobuhiro; Hayashi, Naoki

Proceedings of 13th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.647 - 651, 2016/11

In the J-PARC, a 3 MeV linac has been developed for the tests of beam scraper irradiation and charge exchange by high-power laser. To accomplish tests efficiently and safely, the control system for 3 MeV was designed and developed, and this system consists of four subsystems, personal protection system, machine protection system, timing system, and remote control system using the EPICS. In this paper, the details of control system for a 3 MeV linac are presented.

Journal Articles

Progress of divertor simulation research toward the realization of detached plasma using a large tandem mirror device

Nakashima, Yosuke*; Takeda, Hisahito*; Ichimura, Kazuya*; Hosoi, Katsuhiro*; Oki, Kensuke*; Sakamoto, Mizuki*; Hirata, Mafumi*; Ichimura, Makoto*; Ikezoe, Ryuya*; Imai, Tsuyoshi*; et al.

Journal of Nuclear Materials, 463, p.537 - 540, 2015/08

 Times Cited Count:20 Percentile:83.66(Materials Science, Multidisciplinary)

Journal Articles

Study on heat transfer mechanism elucidation during pool nucleate boiling by measuring instantaneous surface temperature distribution with infrared radiation camera

Koizumi, Yasuo; Takahashi, Kazuki*; Uesawa, Shinichiro; Yoshida, Hiroyuki; Takase, Kazuyuki

Dai-52-Kai Nihon Dennetsu Shimpojiumu Koen Rombunshu (CD-ROM), P. 2, 2015/06

Pool nucleate boiling heat transfer experiments were performed for water at 0.101 MPa to examine the elementary process of the nucleate boiling. The copper printed circuit board of a 1.57 mm thick bakelite plate coated with a 0.035 mm thick copper membrane was used for a heat transfer surface. The size of the heat transfer surface was 10 mm $$times$$ 10 mm. direct current was supplied to it to heat it up. The bakelite plate of the backside of the copper layer was taken by 7 mm $$times$$ 10 mm. The instantaneous variation of the backside temperature of the heat transfer surface was measured with an infrared radiation camera. The time and the space resolution of the infrared cameras used in experiments were 120 Hz and 0.315 mm $$times$$ 0.315 mm, respectively. Surface temperatures just before the burn-out measured with 120 Hz suggest that the surface temperature was steadily low at a large part of the heat transfer surface. A small hot-dry area came out at the critical heat flux condition. Then, this small hot-dry area iterated to expand and shrink and gradually grew. Other area was still wetted and kept at low temperature. Eventually the small hot-dry area started to grow continuously and a whole part of the heat transfer surface became hot-dry to reach the physical burn-out. The heat transfer surface was divided into two large areas; the hot-dry area and the low-temperature wetted area until the physical burn-out. The local surface heat flux variation derived from measured surface temperature variation clearly illustrated that the boundary between the dried area and the wetted area moved back and forth and the dried arear gradually grew to reach physical bourn-out at the critical heat flux condition.

Journal Articles

Study on heat transfer surface temperature variation during pool nucleate boiling by measuring instantaneous surface temperature distribution with infrared radiation camera

Koizumi, Yasuo; Takahashi, Kazuki*; Uesawa, Shinichiro; Yoshida, Hiroyuki; Takase, Kazuyuki

Proceedings of 9th International Conference on Boiling and Condensation Heat Transfer (Boiling & Condensation 2015) (DVD-ROM), 10 Pages, 2015/04

Pool nucleate boiling heat transfer experiments were performed for water at 0.101 MPa to examine the elementary process of the nucleate boiling. The copper printed circuit board of a 1.57 mm thick Bakelite plate coated with a 0.035 mm thick copper membrane was used for a heat transfer surface. The size of the heat transfer surface was 10 mm $$times$$ 10 mm. Direct current was supplied to it to heat it up. The Bakelite plate of the backside of the copper layer was taken by 7 mm $$times$$ 10 mm. The instantaneous variation of the backside temperature of the heat transfer surface was measured with an infrared radiation camera. The time and the space resolution of the infrared cameras used in experiments were 120 Hz and 0.315 mm $$times$$ 0.315 mm, respectively. Surface temperatures just before the burn-out measured with 120 Hz suggest that the surface temperature was steadily low at a large part of the heat transfer surface. A small hot-dry area came out at the critical heat flux condition. Then, this small hot-dry area iterated to expand and shrink and gradually grew. Other area was still wetted and kept at low temperature. Eventually the small hot-dry area started to grow continuously and a whole part of the heat transfer surface became hot-dry to reach the physical burn-out. The heat transfer surface was divided into two large areas; the hot-dry area and the low-temperature-wetted area until the physical burn-out. The local surface heat flux variation derived from measured surface temperature variation clearly illustrated that the boundary between the dried area and the wetted area moved back and forth and the dried arear gradually grew to reach physical bourn-out at the critical heat flux condition.

Journal Articles

Void denuded zone formation for Fe-15Cr-15Ni steel and PNC316 stainless steel under neutron and electron irradiations

Sekio, Yoshihiro; Yamashita, Shinichiro; Sakaguchi, Norihito*; Takahashi, Heishichiro*

Journal of Nuclear Materials, 458, p.355 - 360, 2015/03

 Times Cited Count:23 Percentile:87.9(Materials Science, Multidisciplinary)

Irradiation-induced void denuded zone (VDZ) formation near grain boundaries was studied to clarify the effects of minor alloying elements on vacancy diffusivity during irradiation in PNC316 steel. The test materials were Fe-15Cr-15Ni steel without additives and PNC316 stainless steel, which contains minor alloying elements. These steels were neutron-irradiated in the experimental fast reactor JOYO and electron-irradiation was also carried out using 1 MeV high voltage electron microscopy. VDZ formation was analyzed from the TEM microstructural observations after irradiation. VDZs were formed near random grain boundaries in both Fe-15Cr-15Ni and PNC316 steels. The VDZ widths in the PNC316 steel were narrower than those for the Fe-15Cr-15Ni steel for all neutron and electron irradiations. The VDZ width analysis implied that the vacancy diffusivity was reduced in PNC316 steel as a result of interaction of vacancies with minor alloying elements.

Journal Articles

First flight demonstration of glass-type space solar sheet

Shimazaki, Kazunori*; Kobayashi, Yuki*; Takahashi, Masato*; Imaizumi, Mitsuru*; Murashima, Mio*; Takahashi, Yu*; Toyota, Hiroyuki*; Kukita, Akio*; Oshima, Takeshi; Sato, Shinichiro; et al.

Proceedings of 40th IEEE Photovoltaic Specialists Conference (PVSC-40) (CD-ROM), p.2149 - 2154, 2014/06

The electrical performance of a glass-type space solar sheet (G-SSS) was demonstrated in space. G-SSS comprises InGaP/GaAs dual-junction and InGaP/GaAs/InGaAs triplejunction solar cells. It is lightweight solar generation sheet, less than 0.5 mm thick. It is mounted on the "HISAKI" (SPRINT-A) small scientific satellite, which was launched on September 14, 2013. The initial flight data were successfully acquired and this flight demonstration was a world-first experiment for G-SSS using III-V multi-junction thin-film solar cells. The cells demonstrated superior performance and the electrical outputs matched the flight prediction.

Journal Articles

Effect of additional minor elements on accumulation behavior of point defects under electron irradiation in austenitic stainless steels

Sekio, Yoshihiro; Yamashita, Shinichiro; Sakaguchi, Norihito*; Takahashi, Heishichiro

Materials Transactions, 55(3), p.438 - 442, 2014/03

 Times Cited Count:9 Percentile:42.07(Materials Science, Multidisciplinary)

In order to perform the comparative evaluations for vacancy diffusivity and flux between a base alloy and modified alloys, the void denuded zones (VDZ) widths were measured from the TEM in-situ observation during electron irradiation in the SUS316L, SUS316L-V and SUS316L-Zr steels. As a result, VDZs with given widths were formed near GBs. Then, the VDZ widths were different depending on steels, and the width was narrower due to addition of minor alloying elements which strongly interact with vacancies. Furthermore, from the analyses of measured VDZ widths in the SUS316L and SUS316L-V steels, the changes of vacancy diffusivity, vacancy flux and excess vacancy concentration were estimated as 0.50, 0.71 and 1.41, respectively. The decreases of vacancy diffusivity and flux during electron irradiation would be due to the interaction of vacancies with added minor elements, while the enhancement of the excess vacancy concentration would be caused by trapping effects due to alloying elements.

Journal Articles

Effect of annealing on proton irradiated AlGaN/GaN based micro-Hall sensors

Abderrahmane, A.*; Takahashi, Hiroki*; Tashiro, Tatsuya*; Ko, P. J.*; Okada, Hiroshi*; Sato, Shinichiro; Oshima, Takeshi; Sandhu, A.*

AIP Conference Proceedings 1585, p.123 - 127, 2014/02

 Times Cited Count:1 Percentile:50.91(Physics, Applied)

The effect of annealing at 673 K on irradiated micro-Hall sensors irradiated with protons at 380 keV and fluences of 1$$times 10^{14}$$ cm$$^{-2}$$, 1$$times 10^{15}$$ cm$$^{-2}$$, 1$$times 10^{16}$$ cm$$^{-2}$$ is reported. Cathodoluminescence measurements were carried out at room temperature before and after annealing and showed improvement in the band edge band emission of the GaN layer. After annealing a sensor irradiated by 1$$times 10^{15}$$ cm$$^{-2}$$ the device became operational with improvements in its magnetic sensitivity. All irradiated sensors showed improvement in their electrical characteristics after annealing.

Journal Articles

Partial recovery of the magnetoelectrical properties of AlGaN/GaN-based micro-Hall sensors irradiated with protons

Abderrahmane, A.*; Tashiro, Tatsuya*; Takahashi, Hiroki*; Ko, P. J.*; Okada, Hiroshi*; Sato, Shinichiro; Oshima, Takeshi; Sandhu, A.*

Applied Physics Letters, 104(2), p.023508_1 - 023508_4, 2014/01

 Times Cited Count:6 Percentile:26.7(Physics, Applied)

The effect of annealing on the magnetoelectrical properties of proton-irradiated micro-Hall sensors at an energy of 380 keV and very high proton fluences was studied. Recovery of the electron mobility and a decrease in the sheet resistance of the annealed micro-Hall sensors, as well as an enhancement in their magnetic sensitivity were reported. Trap removal and an improvement in the crystal quality by removing defects were confirmed through current-voltage measurements and Raman spectroscopy, respectively.

Journal Articles

Three-dimensional and multienergy $$gamma$$-ray simultaneous imaging by using a Si/CdTe Compton camera

Suzuki, Yoshiyuki*; Yamaguchi, Mitsutaka; Odaka, Hirokazu*; Shimada, Hirofumi*; Yoshida, Yukari*; Torikai, Kota*; Sato, Takahiro; Arakawa, Kazuo*; Kawachi, Naoki; Watanabe, Shigeki; et al.

Radiology, 267(3), p.941 - 947, 2013/06

 Times Cited Count:23 Percentile:64.83(Radiology, Nuclear Medicine & Medical Imaging)

Journal Articles

Effect of proton irradiation on AlGaN/GaN micro-Hall sensors

Abderrahmane, A.*; Koide, Shota*; Okada, Hiroshi*; Takahashi, Hiroki*; Sato, Shinichiro; Oshima, Takeshi; Sandhu, A.*

Applied Physics Letters, 102(19), p.193510_1 - 193510_4, 2013/05

 Times Cited Count:10 Percentile:41.04(Physics, Applied)

The magnetoelectric properties of AlGaN/GaN micro-Hall effect sensors were studied after 380 keV proton irradiation. After irradiation the current-voltage measurements, stability of the magnetic sensitivity of the sensors, and the sheet electron density were degraded with a dramatic decrease of the electron mobility at high temperatures. Raman spectroscopy showed a degradation in the crystalline quality of GaN crystal, but there was no change in the strain.

Journal Articles

An Evaluation of three-dimensional imaging by use of Si/CdTe Compton cameras

Yamaguchi, Mitsutaka; Nagao, Yuto; Kawachi, Naoki; Fujimaki, Shu; Kamiya, Tomihiro; Odaka, Hirokazu*; Kokubun, Motohide*; Takeda, Shinichiro*; Watanabe, Shin*; Takahashi, Tadayuki*; et al.

Proceedings of 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC), 3 Pages, 2013/00

Journal Articles

High-resolution Compton cameras based on Si/CdTe double-sided strip detectors

Odaka, Hirokazu*; Ichinohe, Yuto*; Takeda, Shinichiro*; Fukuyama, Taro*; Hagino, Koichi*; Saito, Shinya*; Sato, Tamotsu*; Sato, Goro*; Watanabe, Shin*; Kokubun, Motohide*; et al.

Nuclear Instruments and Methods in Physics Research A, 695, p.179 - 183, 2012/12

 Times Cited Count:23 Percentile:83.88(Instruments & Instrumentation)

We have developed a new Si/CdTe semiconductor double-sided strip detector (DSD) Compton camera. The camera consists of a 500-$$mu$$m-thick Si-DSD and four layers of 750-$$mu$$m-thick CdTe-DSDs all of which have common electrode configuration segmented into 128 strips on each side with pitches of 250$$mu$$m. In order to realize high angular resolution and to reduce size of the detector system, a stack of DSDs with short stack pitches of 4 mm is utilized to make the camera. Taking advantage of the excellent energy and position resolutions of the semiconductor devices, the camera achieves high angular resolutions of 4.5 degrees at 356 keV and 3.5 degrees at 662 keV. To obtain such high resolutions together with an acceptable detection efficiency, we demonstrate data reduction methods including energy calibration using Compton scattering continuum and depth sensing in the CdTe-DSD. We also discuss imaging capability of the camera and show simultaneous multi-energy imaging.

Journal Articles

Applications and imaging techniques of a Si/CdTe Compton $$gamma$$-ray camera

Takeda, Shinichiro*; Ichinohe, Yuto*; Hagino, Koichi*; Odaka, Hirokazu*; Yuasa, Takayuki*; Ishikawa, Shinnosuke*; Fukuyama, Taro*; Saito, Shinya*; Sato, Tamotsu*; Sato, Goro*; et al.

Physics Procedia, 37, p.859 - 866, 2012/10

 Times Cited Count:23 Percentile:98.4(Physics, Applied)

By using new Compton camera consisting of silicon double-sided strip detector (Si-DSD) and CdTe-DSD developed for the ASTRO-H mission, an experiment was conducted to study its feasibility for advanced hotspot monitoring. In addition to hotspot imaging already provided by commercial imaging systems, the identification of the variety of radioisotopes is realized thanks to the good energy resolution given by the semiconductor detectors. Three radioisotopes of $$^{133}$$Ba (356 keV), $$^{22}$$Na (511 keV) and $$^{137}$$Cs (662 keV) were individually imaged by applying event selection in the energy window and the $$gamma$$-ray images was correctly overlapped by an optical picture. The detection efficiency of 1.68$$times$$10$$^{-4}$$ (effective area: 1.7$$times$$10$$^{-4}$$ cm$$^2$$) and angular resolution of 3.8$$^{circ}$$ were obtained by stacking five detector modules for 662 keV $$gamma$$-ray. The higher detection efficiency required in a specific use can be achieved by stacking more detector modules.

84 (Records 1-20 displayed on this page)