Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Takahashi, Yoshio*; Miura, Hikaru*; Yamada, Shinya*; Sekizawa, Oki*; Nitta, Kiyofumi*; Hashimoto, Tadashi*; Yomogida, Takumi; Yamaguchi, Akiko; Okada, Shinji*; Itai, Takaaki*; et al.
Journal of Hazardous Materials, 495, p.139031_1 - 139031_19, 2025/09
In this presentation, we analyzed the chemical state of cesium in radiocesium-bearing microparticles (CsMPs) released during the 2011 Fukushima Daiichi Nuclear Power Plant accident using high-resolution X-ray absorption spectroscopy (XANES) and micro X-ray fluorescence (
-XRF). The results identified two forms of cesium: one dissolved in glass and the other enriched on the surfaces of internal voids. The latter is considered to have originally existed as a gas and became concentrated during the cooling and solidification of the molten glass. These findings are crucial for understanding the formation process of CsMPs during the accident, as well as for future decommissioning and safety assessments.
Yomogida, Takumi; Hashimoto, Tadashi; Okumura, Takuma*; Yamada, Shinya*; Tatsuno, Hideyuki*; Noda, Hirofumi*; Hayakawa, Ryota*; Okada, Shinji*; Takatori, Sayuri*; Isobe, Tadaaki*; et al.
Analyst, 149(10), p.2932 - 2941, 2024/03
Times Cited Count:2 Percentile:31.13(Chemistry, Analytical)In this study, we successfully applied a transition-edge sensor (TES) spectrometer as a detector for microbeam X-ray measurements from a synchrotron X-ray light source to determine uranium (U) distribution at the micro-scale and its chemical species in biotite obtained from the U mine. It is difficult to separate the fluorescent X-ray of the U L
line at 13.615 keV from that of the Rb K
line at 13.395 keV in the X-ray fluorescence spectrum with an energy resolution of approximately 220 eV of the conventional silicon drift detector (SDD). Meanwhile, the fluorescent X-rays of U L
and Rb K
were fully separated by TES with 50 eV energy resolution at the energy of around 13 keV. The successful peak separation by TES led to an accurate mapping analysis of trace U in micro-X-ray fluorescence measurements and a decrease in the signal-to-background ratio in micro-X-ray absorption near edge structure spectroscopy.
-edge for Ce in bauxites using transition-edge sensors; Implications for Ti-rich geological samplesLi, W.*; Yamada, Shinya*; Hashimoto, Tadashi; Okumura, Takuma*; Hayakawa, Ryota*; Nitta, Kiyofumi*; Sekizawa, Oki*; Suga, Hiroki*; Uruga, Tomoya*; Ichinohe, Yuto*; et al.
Analytica Chimica Acta, 1240, p.340755_1 - 340755_9, 2023/02
Times Cited Count:16 Percentile:77.24(Chemistry, Analytical)no abstracts in English
Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I.-H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.
IEEE Transactions on Applied Superconductivity, 31(5), p.2101704_1 - 2101704_4, 2021/08
Times Cited Count:3 Percentile:18.03(Engineering, Electrical & Electronic)A superconducting transition-edge sensor (TES) microcalorimeter is an ideal X-ray detector for experiments at accelerator facilities because of good energy resolution and high efficiency. To study the performance of the TES detector with a high-intensity pulsed charged-particle beam, we measured X-ray spectra with a pulsed muon beam at the Japan Proton Accelerator Research Complex (J-PARC) in Japan. We found substantial temporal shifts of the X-ray energy correlated with the arrival time of the pulsed muon beam, which was reasonably explained by pulse pileup due to the incidence of energetic particles from the initial pulsed beam.
X raysOkumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I. H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.
Physical Review Letters, 127(5), p.053001_1 - 053001_7, 2021/07
Times Cited Count:18 Percentile:75.85(Physics, Multidisciplinary)We observed electronic
X rays emitted from muonic iron atoms using a superconducting transition-edge-type sensor microcalorimeter. The energy resolution of 5.2 eV in FWHM allowed us to observe the asymmetric broad profile of the electronic characteristic 
and 
X rays together with the hypersatellite 
X rays around 6 keV. This signature reflects the time-dependent screening of the nuclear charge by the negative muon and the
-shell electrons, accompanied by electron side-feeding. Assisted by a simulation, this data clearly reveals the electronic
- and
-shell hole production and their temporal evolution during the muon cascade process.
Tomizawa, Hiromitsu*; Sato, Takahiro*; Ogawa, Kanade*; Togawa, Kazuaki*; Tanaka, Takatsugu*; Hara, Toru*; Yabashi, Makina*; Tanaka, Hitoshi*; Ishikawa, Tetsuya*; Togashi, Tadashi*; et al.
High Power Laser Science and Engineering, 3, p.e14_1 - e14_10, 2015/04
Times Cited Count:8 Percentile:39.41(Optics)no abstracts in English
Orita, Tadashi; Shimazoe, Kenji*; Takahashi, Hiroyuki*
Nuclear Instruments and Methods in Physics Research A, 775, p.154 - 161, 2015/03
Times Cited Count:29 Percentile:90.52(Instruments & Instrumentation)Recent advances in manufacturing technology have enabled the use of multichannel pixelated detectors in gamma ray imaging applications. When obtaining gamma ray measurements, it is important to obtain pulse height information in order to avoid unnecessary events such as scattering. However, as the number of channels increases, more electronics are needed to process each channel's signal, and the corresponding increases in circuit size and power consumption can result in practical problems. The time over threshold (ToT) method, which has recently become popular in the medical field, is a signal processing technique that can effectively avoid such problems. However, ToT suffers from poor linearity and its dynamic range is limited. We therefore propose a new ToT technique called the dynamic time over threshold (dToT) method. A new signal processing system using dToT and CRRC shaping demonstrated much better linearity than that of a conventional ToT. Using a test circuit with a new Gd
Al
Ga
O
(GAGG) scintillator and an avalanche photodiode, the pulse height spectra of
Cs and
Na sources were measured with high linearity. Based on these results, we designed a new application specific integrated circuit (ASIC) for this multichannel dToT system, measured the spectra of a
Na source, and investigated the linearity of the system.
Sato, Takahiro*; Iwasaki, Atsushi*; Owada, Shigeki*; Yamanouchi, Kaoru*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Togashi, Tadashi*; Fukami, Kenji*; et al.
Journal of Physics B; Atomic, Molecular and Optical Physics, 46(16), p.164006_1 - 164006_6, 2013/08
Times Cited Count:3 Percentile:17.79(Optics)By introducing 13th- (61.7 nm) and 15th-order harmonics (53.4 nm) of femtosecond laser pulses at 800 nm into an undulator of SCSS (SPring-8 Compact SASE Source) test accelerator at RIKEN, these harmonic pulses were amplified by a factor of more than 10
with a high contrast ratio through the interaction between accelerated electron bunches and the harmonic pulses. From numerical simulations of the amplification processes of high-order harmonic pulses in the undulator, optimum conditions of the electron bunch duration interacting with the high-order harmonic pulses were investigated for generating full-coherent and intense pulses in the extreme ultraviolet wavelength region.
Ogawa, Kanade*; Sato, Takahiro*; Matsubara, Shinichi*; Okayasu, Yuichi*; Togashi, Tadashi*; Watanabe, Takahiro*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; et al.
Proceedings of 10th Conference on Lasers and Electro-Optics Pacific Rim and 18th OptoElectronics and Communications Conference and Photonics in Switching 2013 (CLEO-PR & OECC/PS 2013) (USB Flash Drive), 2 Pages, 2013/06
no abstracts in English
Togashi, Tadashi*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Sato, Takahiro*; Iwasaki, Atsushi*; Owada, Shigeki*; Yamanouchi, Kaoru*; Hara, Toru*; et al.
Proceedings of Ultrafast Optics IX (CD-ROM), 2 Pages, 2013/03
We have demonstrated free-electron laser radiation seeded by high-order harmonics in the extreme-ultraviolet region. Strong enhancement of the radiation intensity by a factor of 104 was observed with timing control of an electro-optical sampling technique.
Okayasu, Yuichi*; Tomizawa, Hiromitsu*; Matsubara, Shinichi*; Sato, Takahiro*; Ogawa, Kanade*; Togashi, Tadashi*; Takahashi, Eiji*; Minamide, Hiroaki*; Matsukawa, Ken*; Aoyama, Makoto; et al.
Proceedings of 1st International Beam Instrumentation Conference (IBIC 2012) (Internet), 5 Pages, 2012/10
no abstracts in English
Iwasaki, Atsushi*; Sato, Takahiro*; Owada, Shigeki*; Togashi, Tadashi*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Kannari, Fumihiko*; Yagishita, Akira*; et al.
Reza Kenkyu, 40(9), p.687 - 690, 2012/09
no abstracts in English
Iwasaki, Atsushi*; Sato, Takahiro*; Owada, Shigeki*; Togashi, Tadashi*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Matsubara, Shinichi*; Okayasu, Yuichi*; et al.
Proceedings of International Conference on Ultrafast Phenomena 2012 (UP 2012) (Internet), 3 Pages, 2012/07
Times Cited Count:0 Percentile:0.00(Physics, Multidisciplinary)no abstracts in English
Togashi, Tadashi*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Sato, Takahiro*; Iwasaki, Atsushi*; Owada, Shigeki*; Yamanouchi, Kaoru*; Hara, Toru*; et al.
Proceedings of 11th International School and Symposium on Synchrotron Radiation in Natural Science (ISSRNS 2012), p.1 - 21, 2012/05
The 13th harmonic of a Ti:sapphire laser has been significantly amplified with the SCSS test accelerator. The temporal and spatial overlap of the electron beam and the high harmonic radiation were precisely tuned for achieving the seeded free electron laser operation. With numerical simulation the present HH-seeded FEL scheme could readily be applied to the wavelength region down to 10 nm.
Togashi, Tadashi*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Sato, Takahiro*; Iwasaki, Atsushi*; Okino, Tomoya*; Yamanouchi, Kaoru*; Hara, Toru*; et al.
Proceedings of 2011 Conference on Lasers and Electro-Optics (CLEO 2011) (CD-ROM), p.1527 - 1528, 2011/05
We succeeded in generating the seeded free electron laser (FEL) with wavelengths of 61 nm at the SCSS test accelerator. The 13th (61 nm) harmonics generated by focusing the high peak power Ti:Sapphire laser to the Xe gas cell was directed to the undulator. This is first realization of the seeded FEL in extreme ultraviolet region.
Takahashi, Eiji*; Togashi, Tadashi*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Sato, Takahiro*; Iwasaki, Atsushi*; Owada, Shigeki*; Yamanouchi, Kaoru*; Hara, Toru*; et al.
Proceedings of European Conference on Lasers and Electro-Optics and the 12th European Quantum Electronics Conference (CLEO/Europe-EQEC 2011) (CD-ROM), 1 Pages, 2011/05
We succeeded in generating the seeded free electron laser (FEL) with wavelengths of 61 nm at the SCSS test accelerator. The 13th (61 nm) harmonics generated by focusing the high peak power Ti:Sapphire laser to the Xe gas cell was directed to the undulator. This is first realization of the seeded FEL in extreme ultraviolet region.
Takahashi, Eiji*; Togashi, Tadashi*; Aoyama, Makoto; Yamakawa, Koichi; Sato, Takahiro*; Iwasaki, Atsushi*; Owada, Shigeki*; Yamanouchi, Kaoru*; Hara, Toru*; Matsubara, Shinichi*; et al.
Proceedings of International Quantum Electronics Conference and the Pacific Rim Conference on Lasers and Electro-Optics (IQEC/CLEO Pacific Rim 2011) (CD-ROM), p.199 - 200, 2011/05
We succeeded in generating the seeded free electron laser (FEL) with wavelengths of 61 nm at the SCSS test accelerator. The 13th (61 nm) harmonics generated by focusing the high peak power Ti:Sapphire laser to the Xe gas cell was directed to the undulator. This is first realization of the seeded FEL in extreme ultraviolet region.
Togashi, Tadashi*; Takahashi, Eiji*; Midorikawa, Katsumi*; Aoyama, Makoto; Yamakawa, Koichi; Sato, Takahiro*; Iwasaki, Atsushi*; Owada, Shigeki*; Okino, Tomoya*; Yamanouchi, Kaoru*; et al.
Optics Express (Internet), 19(1), p.317 - 324, 2011/01
Times Cited Count:97 Percentile:95.85(Optics)The 13th harmonic of a Ti:sapphire (Ti:S) laser in the plateau region was injected as a seeding source to a 250-MeV free-electron-laser (FEL) amplifier. When the amplification conditions were fulfilled, strong enhancement of the radiation intensity by a factor of 650 was observed. The random and uncontrollable spikes, which appeared in the spectra of the Self-Amplified Spontaneous Emission (SASE) based FEL radiation without the seeding source, were found to be suppressed drastically to form to a narrow-band, single peak profile at 61.2 nm. The properties of the seeded FEL radiation were well reproduced by numerical simulations. We discuss the future precept of the seeded FEL scheme to the shorter wavelength region.
Hasegawa, Shin; Takahashi, Shuichi*; Iwase, Hiroki*; Koizumi, Satoshi; Morishita, Norio; Sato, Ken*; Narita, Tadashi*; Onuma, Masato*; Maekawa, Yasunari
Polymer, 52(1), p.98 - 106, 2011/01
Times Cited Count:50 Percentile:81.46(Polymer Science)Radiation-induced graft polymerization of sulfo-containing styrene derivatives into poly(ether ether ketone) (PEEK) substrates was carried out to prepare thermally and mechanically stable polymer electrolyte membranes based on an aromatic hydrocarbon polymer. Graft polymerization of ethyl 4-styrenesulfonate into a 32% crystallinity degree PEEK substrate hardly progressed, whereas graft polymerization into 11% PEEK substrate gradually progressed, achieving a grafting degree of more than 50% after 72 h. From Electron Spin Resonance analysis of irradiated PEEK films, it apparent the graft polymerization initiate from the phenoxy radicals. Small-angle X-ray scattering and small-angle neutron scattering observations clearly showed that the graft-type PEEK membranes possessed ion channel domains with the average distance of 13 nm, being larger than that of Nafion. Furthermore, there was a micro-structure in the ion channels with the average distance of 1.8 nm.
Oto, Tsutomu; Kimura, Tadashi; Miyauchi, Masaru; Nemoto, Nobuaki; Tobita, Kenji; Fukasaku, Akitomi; Takahashi, Kunihiro
JAEA-Review 2010-017, 21 Pages, 2010/07
An integrity investigation of a Canal Expanded Joint was carried out as one of the integrity investigation of the JMTR reactor building related facilities and components, before the repair or replacement work of the JMTR related facilities that had begun in FY2007. The Canal Expanded Joint will be used for long-term after the JMTR restart. In the integrity investigation, the visual inspection, the performance test (Surface observations, Durometer hardness test) were investigated respectively and the integrity of the Canal Expanded Joint was confirmed. In order to use the Canal Expanded Joint continuously for long-term, it is important for maintaining the integrity of the Canal Expanded Joint by the periodical maintenance and the repairing work including that has been conducted up to now.