Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 57

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Development of nondestructive elemental analysis system for Hayabusa2 samples using muonic X-rays

Osawa, Takahito; Nagasawa, Shunsaku*; Ninomiya, Kazuhiko*; Takahashi, Tadayuki*; Nakamura, Tomoki*; Wada, Taiga*; Taniguchi, Akihiro*; Umegaki, Izumi*; Kubo, Kenya*; Terada, Kentaro*; et al.

ACS Earth and Space Chemistry (Internet), 7(4), p.699 - 711, 2023/04

 Times Cited Count:4 Percentile:93.95(Chemistry, Multidisciplinary)

The concentrations of carbon and other major elements in asteroid samples provide very important information on the birth of life on the Earth and the solar-system evolution. Elemental analysis using muonic X-rays is one of the best analytical methods to determine the elemental composition of solid materials, and notably, is the only method to determine the concentration of light elements in bulk samples in a non-destructive manner. We developed a new analysis system using muonic X-rays to measure the concentrations of carbon and other major elements in precious and expectedly tiny samples recovered from the asteroid Ryugu by spacecraft Hayabusa2. Here we report the development process of the system in 4 stages and their system configurations, The analysis system is composed of a stainless-steel analysis chamber, an acrylic glove box for manipulating asteroid samples in a clean environment, and Ge semiconductor detectors arranged to surround the analysis chamber. The performance of the analysis system, including the background level, which is crucial for the measurement, was greatly improved from the first stage to the later ones. Our feasibility study showed that the latest model of our muonic X-ray analysis system is capable of determining the carbon concentration in Hayabusa2's sample model with an uncertainty of less than 10 percent in a 6-day measurement.

Journal Articles

Radiocesium-bearing microparticles cause a large variation in $$^{137}$$Cs activity concentration in the aquatic insect ${it Stenopsyche marmorata}$ (Tricoptera: Stenopsychidae) in the Ota River, Fukushima, Japan

Ishii, Yumiko*; Miura, Hikaru*; Jo, J.*; Tsuji, Hideki*; Saito, Rie; Koarai, Kazuma; Hagiwara, Hiroki; Urushidate, Tadayuki*; Nishikiori, Tatsuhiro*; Wada, Toshihiro*; et al.

PLOS ONE (Internet), 17(5), p.e0268629_1 - e0268629_17, 2022/05

 Times Cited Count:3 Percentile:43.07(Multidisciplinary Sciences)

We investigated the variability in $$^{137}$$Cs activity concentration in individual aquatic insects in detritivorous caddisfly (${it Stenopsyche marmorata}$) and carnivorous dobsonfly (${it Protohermes grandis}$) larvae from the Ota River, Fukushima. Caddisfly larvae showed sporadically higher radioactivity, whereas no such outliers were observed in dobsonfly larvae. Autoradiography and scanning electron microscopy analyses confirmed that these caddisfly larvae samples contained radiocesium-bearing microparticles (CsMPs), which are insoluble Cs-bearing silicate glass particles. CsMPs were also found in potential food sources of caddisfly larvae, such as periphyton and drifting particulate organic matter, indicating that larvae may ingest CsMPs along with food particles of similar size. Although CsMPs distribution and uptake by organisms in freshwater ecosystems is relatively unknown, our study demonstrates that CsMPs can be taken up by aquatic insects.

Journal Articles

Extraction behavior of a novel functionalized ionic liquid for separation of platinum group metals from aqueous nitric acid solution

Ito, Tatsuya; Osugi, Haruka*; Osawa, Naoki*; Takahashi, Tadayuki*; Kim, S.-Y.*; Nagaishi, Ryuji

Analytical Sciences, 38(1), p.91 - 97, 2022/01

 Times Cited Count:2 Percentile:15.48(Chemistry, Analytical)

A novel ionic liquid (IL) functionalized with thiodiglycol amic acid containing a soft S donor was synthesized for the effective and efficient extraction of platinum group metals (Ru, Rh, and Pd) from aqueous nitric acid solutions, such as high-level radioactive liquid waste (HLLW). The IL allowed a rapid extraction of Pd(II) with an extraction ratio of approximately 100%. The extractions of Ru(III) and Rh(III) by the IL were slower than that of Pd(II), but the rates were accelerated by temperature elevation. The extractions of Ru(III) and Rh(III) at 50$$^{circ}$$C reached equilibrium within 4 and 8 h, respectively, with the extraction ratios of over 90% without assisting agents or other methods for the extraction system. Furthermore, the IL could extract more than 90% of Ru(III), Rh(III), and Pd(II) from the simulated HLLW within 2 h at 50$$^{circ}$$C.

Journal Articles

Dynamical response of transition-edge sensor microcalorimeters to a pulsed charged-particle beam

Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I.-H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.

IEEE Transactions on Applied Superconductivity, 31(5), p.2101704_1 - 2101704_4, 2021/08

 Times Cited Count:1 Percentile:11.15(Engineering, Electrical & Electronic)

A superconducting transition-edge sensor (TES) microcalorimeter is an ideal X-ray detector for experiments at accelerator facilities because of good energy resolution and high efficiency. To study the performance of the TES detector with a high-intensity pulsed charged-particle beam, we measured X-ray spectra with a pulsed muon beam at the Japan Proton Accelerator Research Complex (J-PARC) in Japan. We found substantial temporal shifts of the X-ray energy correlated with the arrival time of the pulsed muon beam, which was reasonably explained by pulse pileup due to the incidence of energetic particles from the initial pulsed beam.

Journal Articles

Deexcitation dynamics of muonic atoms revealed by high-precision spectroscopy of electronic $$K$$ X rays

Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I. H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.

Physical Review Letters, 127(5), p.053001_1 - 053001_7, 2021/07

 Times Cited Count:13 Percentile:79.44(Physics, Multidisciplinary)

We observed electronic $$K$$X rays emitted from muonic iron atoms using a superconducting transition-edge-type sensor microcalorimeter. The energy resolution of 5.2 eV in FWHM allowed us to observe the asymmetric broad profile of the electronic characteristic $$K$$$$alpha$$ and $$K$$$$beta$$ X rays together with the hypersatellite $$K$$$$alpha$$ X rays around 6 keV. This signature reflects the time-dependent screening of the nuclear charge by the negative muon and the $$L$$-shell electrons, accompanied by electron side-feeding. Assisted by a simulation, this data clearly reveals the electronic $$K$$- and $$L$$-shell hole production and their temporal evolution during the muon cascade process.

Journal Articles

Corrigendum: Beam range estimation by measuring bremsstrahlung (2012 Phys. Med. Biol. 57 2843)

Yamaguchi, Mitsutaka; Torikai, Kota*; Kawachi, Naoki; Shimada, Hirofumi*; Sato, Takahiro; Nagao, Yuto; Fujimaki, Shu; Kokubun, Motohide*; Watanabe, Shin*; Takahashi, Tadayuki*; et al.

Physics in Medicine & Biology, 61(9), p.3638 - 3644, 2016/05

 Times Cited Count:9 Percentile:100(Engineering, Biomedical)

no abstracts in English

Journal Articles

Three-dimensional and multienergy $$gamma$$-ray simultaneous imaging by using a Si/CdTe Compton camera

Suzuki, Yoshiyuki*; Yamaguchi, Mitsutaka; Odaka, Hirokazu*; Shimada, Hirofumi*; Yoshida, Yukari*; Torikai, Kota*; Sato, Takahiro; Arakawa, Kazuo*; Kawachi, Naoki; Watanabe, Shigeki; et al.

Radiology, 267(3), p.941 - 947, 2013/06

 Times Cited Count:23 Percentile:65.03(Radiology, Nuclear Medicine & Medical Imaging)

Journal Articles

An Evaluation of three-dimensional imaging by use of Si/CdTe Compton cameras

Yamaguchi, Mitsutaka; Nagao, Yuto; Kawachi, Naoki; Fujimaki, Shu; Kamiya, Tomihiro; Odaka, Hirokazu*; Kokubun, Motohide*; Takeda, Shinichiro*; Watanabe, Shin*; Takahashi, Tadayuki*; et al.

Proceedings of 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC), 3 Pages, 2013/00

Journal Articles

A New method for monitoring beam range by measuring low energy photons

Yamaguchi, Mitsutaka; Torikai, Kota*; Kawachi, Naoki; Shimada, Hirofumi*; Sato, Takahiro; Nagao, Yuto; Fujimaki, Shu; Kokubun, Motohide*; Watanabe, Shin*; Takahashi, Tadayuki*; et al.

Proceedings of 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC), 2 Pages, 2013/00

Journal Articles

High-resolution Compton cameras based on Si/CdTe double-sided strip detectors

Odaka, Hirokazu*; Ichinohe, Yuto*; Takeda, Shinichiro*; Fukuyama, Taro*; Hagino, Koichi*; Saito, Shinya*; Sato, Tamotsu*; Sato, Goro*; Watanabe, Shin*; Kokubun, Motohide*; et al.

Nuclear Instruments and Methods in Physics Research A, 695, p.179 - 183, 2012/12

 Times Cited Count:23 Percentile:84.01(Instruments & Instrumentation)

We have developed a new Si/CdTe semiconductor double-sided strip detector (DSD) Compton camera. The camera consists of a 500-$$mu$$m-thick Si-DSD and four layers of 750-$$mu$$m-thick CdTe-DSDs all of which have common electrode configuration segmented into 128 strips on each side with pitches of 250$$mu$$m. In order to realize high angular resolution and to reduce size of the detector system, a stack of DSDs with short stack pitches of 4 mm is utilized to make the camera. Taking advantage of the excellent energy and position resolutions of the semiconductor devices, the camera achieves high angular resolutions of 4.5 degrees at 356 keV and 3.5 degrees at 662 keV. To obtain such high resolutions together with an acceptable detection efficiency, we demonstrate data reduction methods including energy calibration using Compton scattering continuum and depth sensing in the CdTe-DSD. We also discuss imaging capability of the camera and show simultaneous multi-energy imaging.

Journal Articles

Applications and imaging techniques of a Si/CdTe Compton $$gamma$$-ray camera

Takeda, Shinichiro*; Ichinohe, Yuto*; Hagino, Koichi*; Odaka, Hirokazu*; Yuasa, Takayuki*; Ishikawa, Shinnosuke*; Fukuyama, Taro*; Saito, Shinya*; Sato, Tamotsu*; Sato, Goro*; et al.

Physics Procedia, 37, p.859 - 866, 2012/10

 Times Cited Count:22 Percentile:98.43(Physics, Applied)

By using new Compton camera consisting of silicon double-sided strip detector (Si-DSD) and CdTe-DSD developed for the ASTRO-H mission, an experiment was conducted to study its feasibility for advanced hotspot monitoring. In addition to hotspot imaging already provided by commercial imaging systems, the identification of the variety of radioisotopes is realized thanks to the good energy resolution given by the semiconductor detectors. Three radioisotopes of $$^{133}$$Ba (356 keV), $$^{22}$$Na (511 keV) and $$^{137}$$Cs (662 keV) were individually imaged by applying event selection in the energy window and the $$gamma$$-ray images was correctly overlapped by an optical picture. The detection efficiency of 1.68$$times$$10$$^{-4}$$ (effective area: 1.7$$times$$10$$^{-4}$$ cm$$^2$$) and angular resolution of 3.8$$^{circ}$$ were obtained by stacking five detector modules for 662 keV $$gamma$$-ray. The higher detection efficiency required in a specific use can be achieved by stacking more detector modules.

Journal Articles

Beam range estimation by measuring bremsstrahlung

Yamaguchi, Mitsutaka; Torikai, Kota*; Kawachi, Naoki; Shimada, Hirofumi*; Sato, Takahiro; Nagao, Yuto; Fujimaki, Shu; Kokubun, Motohide*; Watanabe, Shin*; Takahashi, Tadayuki*; et al.

Physics in Medicine & Biology, 57(10), p.2843 - 2856, 2012/05

 Times Cited Count:41 Percentile:79.35(Engineering, Biomedical)

Journal Articles

Three-dimensional imaging test for a head module of a Si/CdTe Compton camera for medical application

Yamaguchi, Mitsutaka; Kawachi, Naoki; Kamiya, Tomihiro; Sato, Takahiro; Suzui, Nobuo; Fujimaki, Shu; Odaka, Hirokazu*; Ishikawa, Shinnosuke*; Kokubun, Motohide*; Watanabe, Shin*; et al.

JAEA-Review 2011-043, JAEA Takasaki Annual Report 2010, P. 145, 2012/01

no abstracts in English

Journal Articles

Development of head module for multi-head Si/CdTe Compton camera for medical applications

Yamaguchi, Mitsutaka; Kawachi, Naoki; Suzui, Nobuo; Fujimaki, Shu; Kamiya, Tomihiro; Odaka, Hirokazu*; Ishikawa, Shinnosuke*; Kokubun, Motohide*; Watanabe, Shin*; Takahashi, Tadayuki*; et al.

Nuclear Instruments and Methods in Physics Research A, 648(Suppl.1), p.S2 - S7, 2011/08

 Times Cited Count:2 Percentile:19.86(Instruments & Instrumentation)

We are constructing a three-dimensional imaging system for medical and biological applications. The system will allow simultaneous imaging at high spatial and energy resolutions across a wide energy range, from several tens of keV to a few MeV. In this work, one prototype head module have been developed for a multi-head Si/CdTe Compton camera system. The performance of the prototype was evaluated with a sealed Ba-133 radiation source. The experiments confirmed that the imaging results were consistent with actual source position. In addition to the resolution for the parallel directions to the detector surface, the position resolution was evaluated for the depth direction at a point in near region of the head-module. These position resolutions were well reproduced by Monte Carlo simulation results.

Journal Articles

Counting rate performance measurement of newly developed Si/CdTe Compton camera for biological and medical applications

Yamaguchi, Mitsutaka; Kawachi, Naoki; Kamiya, Tomihiro; Suzui, Nobuo; Fujimaki, Shu; Odaka, Hirokazu*; Ishikawa, Shinnosuke*; Kokubun, Motohide*; Watanabe, Shin*; Takahashi, Tadayuki*; et al.

2010 IEEE Nuclear Science Symposium Conference Record (CD-ROM), p.2004 - 2007, 2010/10

Journal Articles

Experimental results of the $$gamma$$-ray imaging capability with a Si/CdTe semiconductor Compton camera

Takeda, Shinichiro*; Aono, Hiroyuki*; Okuyama, Sho*; Ishikawa, Shinnosuke*; Odaka, Hirokazu*; Watanabe, Shin*; Kokubun, Motohide*; Takahashi, Tadayuki*; Nakazawa, Kazuhiro*; Tajima, Hiroyasu*; et al.

IEEE Transactions on Nuclear Science, 56(3), p.783 - 790, 2009/06

 Times Cited Count:56 Percentile:96.13(Engineering, Electrical & Electronic)

Journal Articles

Basic characteristics of a newly developed Si/CdTe Compton camera for medical imaging

Kawachi, Naoki; Watanabe, Shigeki; Sato, Takahiro; Arakawa, Kazuo; Takeda, Shinichiro*; Ishikawa, Shinnosuke*; Aono, Hiroyuki*; Watanabe, Shin*; Yamaguchi, Mitsutaka*; Takahashi, Tadayuki*; et al.

2008 IEEE Nuclear Science Symposium Conference Record (CD-ROM), p.1540 - 1543, 2008/10

Journal Articles

Monte Carlo simulation of multi-head Si/CdTe Compton camera for medical imaging

Yamaguchi, Mitsutaka*; Kawachi, Naoki; Watanabe, Shin*; Odaka, Hirokazu*; Takeda, Shinichiro*; Ishikawa, Shinnosuke*; Aono, Hiroyuki*; Takahashi, Tadayuki*; Arakawa, Kazuo; Nakano, Takashi*

2008 IEEE Nuclear Science Symposium Conference Record (CD-ROM), p.4000 - 4002, 2008/10

Journal Articles

Design and installation of ferritic steel tiles for ripple reduction of toroidal magnetic field in JT-60U

Sasajima, Tadayuki; Masaki, Kei; Sakurai, Shinji; Shibama, Yusuke; Hayashi, Takao; Suzuki, Yutaka; Takahashi, Ryukichi

Heisei-18-Nendo Nagoya Daigaku Sogo Gijutsu Kenkyukai Sochi Gijutsu Kenkyukai Hokokushu, p.148 - 151, 2007/03

no abstracts in English

Journal Articles

The Remote transmission test of the GUAM measurement data by the wireless LAN

Asano, Takashi; Fujiwara, Shigeo; Takahashi, Saburo; Nemoto, Tadayuki*; Sato, Takashi*; Kuniyasu, Kazufusa*; Hiruta, Kazuhiko*

Kaku Busshitsu Kanri Gakkai (INMM) Nihon Shibu Dai-28-Kai Nenji Taikai Rombunshu (CD-ROM), 11 Pages, 2007/00

JAEA has developed and demonstrated the Remote Monitoring (RM) technology on the safeguards equipment at the storage area in PFPF to improve the efficiency of the inspection activity. JAEA is considering the expansion of the RM technology to the safeguards equipment in the process area to improve the efficiency of the inspection activity under the integrated safeguards. JAEA considers that the cabling cost and work in the facility will be reduced to apply the wireless LAN to the RM technology. JAEA performed the confirmatory testing of the performance of the Glove box Unattended Assay and Monitoring system (GUAM) and the remote transmission of the GUAM measurement data by the wireless LAN in cooperation with Japan Nuclear Fuel Limited. In this test, JAEA confirmed it's possible to establish the wireless LAN networking in the process area. This paper reports the applicability of the wireless LAN to the RM technology based on the results of the confirmatory testing.

57 (Records 1-20 displayed on this page)