Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
He neutron spin filter at J-PARCTakahashi, Shingo; Kiyanagi, Ryoji; Okudaira, Takuya*; Takada, Shusuke*; Kobayashi, Ryuju; Okuizumi, Mao; Ino, Takashi*; Asai, Kanta*; Tsuchikawa, Yusuke; Oikawa, Kenichi; et al.
Nuclear Instruments and Methods in Physics Research A, 1075, p.170410_1 - 170410_8, 2025/06
Times Cited Count:0 Percentile:0.00(Instruments & Instrumentation)Hayashi, Teppei*; Yamashita, Takuma*; Mitsuyasu, Yusuke*; Ono, Kenta*; Iwami, Satone*; Kino, Yasushi*; Sekine, Tsutomu*; Oka, Toshitaka; Takahashi, Atsushi*; Shimizu, Yoshinaka*; et al.
International Journal of Radiation Biology, 8 Pages, 2025/00
Times Cited Count:0 Percentile:0.00no abstracts in English
Yamashita, Takuma*; Hayashi, Teppei*; Mitsuyasu, Yusuke*; Ono, Kenta*; Iwami, Satone*; Kino, Yasushi*; Sekine, Tsutomu*; Oka, Toshitaka; Takahashi, Atsushi*; Shimizu, Yoshinaka*; et al.
International Journal of Radiation Biology, 8 Pages, 2025/00
Times Cited Count:1 Percentile:73.02(Biology)no abstracts in English
Nagasawa, Makoto*; Shimizu, Yusuke*; Yamaguchi, Akiko; Tokunaga, Kohei; Mukai, Hiroki*; Aoyagi, Noboru; Mei, H.; Takahashi, Yoshio*
Chemical Geology, 670, p.122431_1 - 122431_25, 2024/12
Times Cited Count:5 Percentile:82.67(Geochemistry & Geophysics)Iwami, Satone*; Yamashita, Takuma*; Mitsuyasu, Yusuke*; Ono, Kenta*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.
KEK Proceedings 2024-6, p.91 - 95, 2024/12
We aim to improve the detection limit of the ESR dosimetry method. In this study, the saturation behavior of each radical was investigated by varying the microwave power during ESR measurement. Based on the difference in spin relaxation time between carbonate radicals and native radicals, it is expected that the signal-to-noise ratio improves and the detection limit can be lowered when the microwave power is increased to 4.0 mW.
Yamashita, Takuma*; Iwami, Satone*; Mitsuyasu, Yusuke*; Ono, Kenta*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.
KEK Proceedings 2024-6, p.85 - 90, 2024/12
To clarify the radiation effects of the accident at the TEPCO's Fukushima Daiichi NPP on living organisms, it is important to accurately estimate the dose to each individual. We have developed a multi-component analysis program using random number optimization to extract only the components derived from carbonate radicals from the ESR spectra.
-odd/
-odd interactions on the 0.75 eV
-wave resonance in
+
forward transmission determined using a pulsed neutron beamNakabe, Rintaro*; Auton, C. J.*; Endo, Shunsuke; Fujioka, Hiroyuki*; Gudkov, V.*; Hirota, Katsuya*; Ide, Ikuo*; Ino, Takashi*; Ishikado, Motoyuki*; Kambara, Wataru*; et al.
Physical Review C, 109(4), p.L041602_1 - L041602_4, 2024/04
Times Cited Count:1 Percentile:9.15(Physics, Nuclear)
-wave resonance of 
+
Okudaira, Takuya*; Nakabe, Rintaro*; Auton, C. J.*; Endo, Shunsuke; Fujioka, Hiroyuki*; Gudkov, V.*; Ide, Ikuo*; Ino, Takashi*; Ishikado, Motoyuki*; Kambara, Wataru*; et al.
Physical Review C, 109(4), p.044606_1 - 044606_9, 2024/04
Times Cited Count:2 Percentile:54.52(Physics, Nuclear)Kamewari, Ryusei*; Fujishima, Yusuke*; Kawabata, Kuniaki; Suzuki, Kenta; Sakagami, Norimitsu*; Takemura, Fumiaki*; Takahashi, Satoru*
Proceedings of the IUTAM Symposium on Optimal Guidance and Control for Autonomous Systems 2023 (IUTAM Bookseries No.40), p.85 - 101, 2024/01
Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.
Radiation Protection Dosimetry, 199(14), p.1620 - 1625, 2023/09
Times Cited Count:2 Percentile:33.46(Environmental Sciences)We have been conducting dose assessments for Japanese macaques captured in Fukushima to reveal radiobiological effects on the low-dose expose animals. To accurately determine the external exposure dose, it is desirable to examine the analysis of the CO
radical intensity. We examined ESR spectra of teeth of 10 macaques captured in Fukushima by two spectrum-decomposition algorithms.
Ohashi, Yusuke; Shimaike, Masamitsu; Matsumoto, Takashi; Takahashi, Nobuo; Yokoyama, Kaoru; Morimoto, Yasuyuki
Nuclear Technology, 209(5), p.777 - 786, 2023/05
Times Cited Count:0 Percentile:0.00(Nuclear Science & Technology)At the Ningyo-Toge Center, technical development related to uranium refining conversion and enrichment has been completed, and decommissioning of these facilities has begun. The error between the quantity of dismantled materials estimated from the facility design drawings and the actual quantity of dismantled materials was minimal when averaging over the entire Uranium Refining and Conversion Plant and Uranium Enrichment Engineering Facility, which results indicated that the preliminary estimate of the quantity of dismantled materials for decommissioning was reasonable. Most of the dismantled materials, which have no contamination history and are properly managed were able to be carried out to recyclers as non-radioactive waste (NR). In addition, the possibility of evaluating the uranium concentration of clearance level in dismantled objects was confirmed through gamma-ray measurement tests using mock-up waste.
-edge for Ce in bauxites using transition-edge sensors; Implications for Ti-rich geological samplesLi, W.*; Yamada, Shinya*; Hashimoto, Tadashi; Okumura, Takuma*; Hayakawa, Ryota*; Nitta, Kiyofumi*; Sekizawa, Oki*; Suga, Hiroki*; Uruga, Tomoya*; Ichinohe, Yuto*; et al.
Analytica Chimica Acta, 1240, p.340755_1 - 340755_9, 2023/02
Times Cited Count:16 Percentile:77.24(Chemistry, Analytical)no abstracts in English
Yoshimune, Wataru*; Kikkawa, Nobuaki*; Yoneyama, Hiroaki*; Takahashi, Naoko*; Minami, Saori*; Akimoto, Yusuke*; Mitsuoka, Takuya*; Kawaura, Hiroyuki*; Harada, Masashi*; Yamada, Norifumi*; et al.
ACS Applied Materials & Interfaces, 14(48), p.53744 - 53754, 2022/11
Times Cited Count:13 Percentile:67.17(Nanoscience & Nanotechnology)Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.
KEK Proceedings 2022-2, p.120 - 125, 2022/11
We investigate the effect of sample's anisotropy and measurement condition to obtain the higher reproducibility for the shape of the ESR spectrum and the intensity of CO
radical.
Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.
KEK Proceedings 2021-2, p.91 - 96, 2021/12
We examined whether the ESR dose estimation method could be applied to wild Japanese macaque. In this work, we investigated the enamel preparation protocol and the analytical method of the ESR spectra.
Ono, Koki*; Higomoto, Toshiya*; Saito, Yugo*; Uchino, Shun; Nishida, Yusuke*; Takahashi, Yoshiro*
Nature Communications (Internet), 12, p.6724_1 - 6724_8, 2021/11
Times Cited Count:10 Percentile:60.85(Multidisciplinary Sciences)Quantum transport is ubiquitous in physics. So far, quantum transport between terminals has been extensively studied in solid state systems from the fundamental point of views such as the quantized conductance to the applications to quantum devices. Recent works have demonstrated a cold-atom analog of a mesoscopic conductor by engineering a narrow conducting channel with optical potentials, which opens the door for a wealth of research of atomtronics emulating mesoscopic electronic devices and beyond. Here we realize an alternative scheme of the quantum transport experiment with ytterbium atoms in a two-orbital optical lattice system. Our system consists of a multi-component Fermi gas and a localized impurity, where the current can be created in the spin space by introducing the spin-dependent interaction with the impurity. We demonstrate a rich variety of localized-impurity-induced quantum transports, which paves the way for atomtronics exploiting spin degrees of freedom.
Fukuda, Tatsuya*; Takahashi, Ryo*; Hara, Takuhi*; Ohara, Koji*; Kato, Kazuo*; Matsumura, Daiju; Inaba, Yusuke*; Nakase, Masahiko*; Takeshita, Kenji*
Journal of Nuclear Science and Technology, 58(4), p.399 - 404, 2021/04
Times Cited Count:8 Percentile:56.21(Nuclear Science & Technology)Saga, Ryo*; Matsuya, Yusuke; Takahashi, Rei*; Hasegawa, Kazuki*; Date, Hiroyuki*; Hosokawa, Yoichiro*
Scientific Reports (Internet), 11(1), p.8258_1 - 8258_10, 2021/04
Times Cited Count:6 Percentile:50.71(Multidisciplinary Sciences)Hyaluronan synthesis inhibitor 4-methylumbelliferone (4-MU) is a candidate of radiosensitizers in X-ray therapy. The curative effects under such 4-MU administration have been investigated in vitro; however, the radiosensitizing mechanisms remain unclear. Here, we investigated the radiosensitizing effects under 4-MU treatment from cell experiments and model estimations. We generated experimental surviving fractions of human fibrosarcoma cells (HT1080) after 4-MU treatment combined with X-ray irradiation. Meanwhilst, we also modelled the pharmacological effects of 4-MU treatment and theoretically analyzed the synergetic effects between 4-MU treatment and X-ray irradiation. The results show that the enhancement of cell killing by 4-MU treatment is the greatest in the intermediate dose range of around 4 Gy, which indicates the involvement of intercellular communication. In addition, the oxidative stress level, which leads to DNA damage induction, significantly increased under 4-MU treatment, and the radiosensitization by 4-MU can be suppressed by the inhibitors for intercellular communication. These findings suggest that the synergetic effects between 4-MU treatment and irradiation are predominantly attributed to intercellular communication and provide more efficient tumour control than conventional X-ray therapy.
Hashimoto, Makoto; Kinase, Sakae; Munakata, Masahiro; Murayama, Takashi; Takahashi, Masa; Takada, Chie; Okamoto, Akiko; Hayakawa, Tsuyoshi; Sukegawa, Masato; Kume, Nobuhide*; et al.
JAEA-Review 2020-071, 53 Pages, 2021/03
In the case of a nuclear accident or a radiological emergency, the Japan Atomic Energy Agency (JAEA), as a designated public corporation assigned in the Disaster Countermeasures Basic Act and the Armed Attack Situation Response Law, undertakes technical supports to the national government and local governments. The JAEA is requested to support to evaluate radiation doses to residents in a nuclear emergency, which is specified in the Basic Disaster Management Plan and the Nuclear Emergency Response Manual. For the dose evaluation, however, its strategy, target, method, structure and so on have not been determined either specifically or in detail. This report describes the results of investigation and consideration discussed in the "Working Group for Radiation Dose Evaluation at a Nuclear Emergency" established within the Nuclear Emergency Assistance and Training Center to discuss technical supports for radiation dose evaluation to residents in the case of a nuclear emergency, and aims at contributing to specific and detailed discussion and activities in the future for the national government and local governments, also within the JAEA.
Miyajima, Yusuke*; Saito, Ayaka*; Kagi, Hiroyuki*; Yokoyama, Tatsunori; Takahashi, Yoshio*; Hirata, Takafumi*
Geostandards and Geoanalytical Research, 45(1), p.189 - 205, 2021/03
Times Cited Count:6 Percentile:28.35(Geochemistry & Geophysics)Uncertainty for elemental and isotopic analyses of calcite by LA-ICP-MS is largely controlled by the homogeneity of the reference materials (RMs) used for normalization and validation. In order to produce calcite RMs with homogeneous elemental and isotopic compositions, we incorporated elements including U, Pb, and rare earth elements into calcite through heat- and pressure-induced crystallization from amorphous calcium carbonate that was precipitated from element-doped reagent solution. X-ray absorption spectra showed that U was present as U(VI) in the synthesized calcite, probably with a different local structure from that of aqueous uranyl ions. The uptake rate of U by our calcite was higher in comparison to synthetic calcite of previous studies. Variations of element mass fractions in the calcite were better than 12% 2RSD, mostly within 7%. The
Pb/
Pb ratio in the calcite showed
1% variations, while the
U/
Pb ratio showed 3-24% variations depending on element mass fractions. Using the synthetic calcite as primary RMs, we could date a natural calcite RM, WC-1, with analytical uncertainty as low as
3%. The method presented can be useful to produce calcite with controlled and homogeneous element mass fractions, and is a promising alternative to natural calcite RMs for U-Pb geochronology.