Kokubu, Yoko; Fujita, Natsuko; Miyake, Masayasu; Watanabe, Takahiro; Ishizaka, Chika; Okabe, Nobuaki; Ishimaru, Tsuneari; Matsubara, Akihiro*; Nishizawa, Akimitsu*; Nishio, Tomohiro*; et al.
Nuclear Instruments and Methods in Physics Research B, 456, p.271 - 275, 2019/10
Times Cited Count:2 Percentile:26.7(Instruments & Instrumentation)JAEA-AMS-TONO has been in operation at the Tono Geoscience Center, Japan Atomic Energy Agency since 1998 and 20 years have passed from the beginning of its utilization. The AMS system is a versatile system based on a 5 MV tandem Pelletron type accelerator. The system has been used to measure carbon-14 (C), beryllium-10 (
Be) and aluminium-26 (
Al). In addition, the development of measurement of iodine-129 (
I) has been started. The main use is measurement of
C in geological samples for dating studies in neotectonics and hydrogeology. In order to increase the speed of sample preparation, we introduced the automated graphitization equipment and made a gas-strip line to collect dissolved inorganic carbon in groundwater samples. Measurement of
Be and
Al has been used for geoscience studies and the detection limit in the measurement of
Be was improved by
Be-counting suppression. Recently tuning of measurement condition of
I has been progressed.
Watanabe, Takahiro; Kokubu, Yoko; Fujita, Natsuko; Ishizaka, Chika*; Nishio, Tomohiro; Matsubara, Akihiro*; Miyake, Masayasu; Kato, Motohisa*; Isozaki, Nobuhiro*; Torazawa, Hitoshi*; et al.
JAEA-Conf 2018-002, p.116 - 119, 2019/02
AMS is widely used for radiocarbon dating of geological samples. However, improvement in efficiency of sample preparation techniques are needed for high-time resolution dataset. In 2016, automated graphitization equipment (AGE3, IonPlus AG) has been installed in Toki Research Institute of Isotope Geology and Geochronology, Tono Geoscience Center, JAEA. Background values and carbon recovery rates during preparation process of AGE3 should be estimated before application in radiocarbon dating. In this study, the AGE3 system was evaluated using the international standard materials (IAEA-C1, C4, C5, C6, C7, C9 and NIST-SRM4990C) at JAEA-AMS-TONO. Graphite samples was prepared by the AGE3 system and radiocarbon concentration of these standards was measured by AMS. The results were agreement with the consensus values. Background values were 0.150.01 pMC (IAEA-C1) using the AGE3 system. Therefore, we concluded that the system can be adapted for radiocarbon dating of geological samples.
Kokubu, Yoko; Fujita, Natsuko; Matsubara, Akihiro*; Nishizawa, Akimitsu*; Nishio, Tomohiro; Miyake, Masayasu; Ishimaru, Tsuneari; Watanabe, Takahiro; Ogata, Nobuhisa; Shimada, Akiomi; et al.
JAEA-Conf 2018-002, p.5 - 8, 2019/02
no abstracts in English
Fujita, Natsuko; Miyake, Masayasu; Watanabe, Takahiro; Kokubu, Yoko; Ishimaru, Tsuneari; Matsubara, Akihiro*; Nishio, Tomohiro*; Kato, Motohisa*; Isozaki, Nobuhiro*; Torazawa, Hitoshi*; et al.
JAEA-Conf 2018-013, p.96 - 99, 2019/02
no abstracts in English
Fujita, Natsuko; Miyake, Masayasu; Watanabe, Takahiro; Kokubu, Yoko; Matsubara, Akihiro*; Kato, Motohisa*; Okabe, Nobuaki; Isozaki, Nobuhiro*; Ishizaka, Chika*; Torazawa, Hitoshi*; et al.
Dai-31-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.92 - 95, 2018/12
no abstracts in English
Fujita, Natsuko; Miyake, Masayasu; Watanabe, Takahiro; Kokubu, Yoko; Ishimaru, Tsuneari; Matsubara, Akihiro*; Isozaki, Nobuhiro*; Nishio, Tomohiro*; Kato, Motohisa*; Torazawa, Hitoshi*; et al.
Dai-19-Kai AMS Shimpojiumu, 2016-Nendo "Jumoku Nenrin" Kenkyukai Kyodo Kaisai Shimpojiumu Hokokushu, p.68 - 71, 2017/06
no abstracts in English
Watanabe, Takahiro; Kokubu, Yoko; Fujita, Natsuko; Matsubara, Akihiro*; Nishio, Tomohiro*; Miyake, Masayasu; Kato, Motohisa*; Isozaki, Nobuhiro*; Torazawa, Hitoshi*; Nishizawa, Akimitsu*; et al.
no journal, ,
Radiocarbon dating by Accelerator Mass Spectrometry is widely used for earth and environmental sciences. For high-precision analyses, automatic preparation system and standard methods are needed. The preparation system by elemental analyzer (EA) has been reported. However, we should make clear the changes in background level during the preparation. In this study, we continued radiocarbon dating of international standard materials using the EA at JAEA-AMS-TONO. The radiocarbon concentrations of the standard materials were agreement with the consensus values within 2 sigma.