Refine your search:     
Report No.
 - 
Search Results: Records 1-14 displayed on this page of 14
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Beam position monitor system of J-PARC RCS

Hayashi, Naoki; Kawase, Masato; Hatakeyama, Shuichiro; Hiroki, Seiji; Saeki, Riuji; Takahashi, Hiroki; Teruyama, Yuzo*; Toyokawa, Ryoji*; Arakawa, Dai*; Hiramatsu, Shigenori*; et al.

Nuclear Instruments and Methods in Physics Research A, 677, p.94 - 106, 2012/06

 Times Cited Count:12 Percentile:66.72(Instruments & Instrumentation)

A beam position monitor (BPM) system at J-PARC RCS is described. The J-PARC RCS is a rapid-cycling proton synchrotron and its designed beam power is 1 MW. A diameter of the BPM detector is larger than 250 mm, however the system has to measure the beam position very accurately. The system should work not only for the high intensity but also for lower intensity. There are 54 BPM around the ring and most of them are placed inside steering magnets because of quite limited space. The BPM detector is an electro static type and it has four electrodes, and a pair of electrode gives a good linear response with diagonal cut shape to detect the charge center precisely. The signal processing unit, which is equipped with 14-bit 40 MSPS ADC and 600 MHz DSP, has been developed. They are controlled via shared memory space and EPICS. It is capable to record full 25 Hz pulse data for averaged mode and it could also store whole waveform data for further analysis, like turn-by-turn position calculation.

Journal Articles

Field measurement of DC magnets at 3-GeV RCS in J-PARC

Yoshimoto, Masahiro; Ueno, Tomoaki; Togashi, Tomohito; Toyokawa, Ryoji; Takeda, Osamu; Watanabe, Masao; Yamazaki, Yoshio; Yamamoto, Kazami; Kamiya, Junichiro; Takayanagi, Tomohiro; et al.

IEEE Transactions on Applied Superconductivity, 18(2), p.301 - 305, 2008/06

 Times Cited Count:1 Percentile:12.91(Engineering, Electrical & Electronic)

Journal Articles

Beam instrumentations for the J-PARC RCS commissioning

Hayashi, Naoki; Hiroki, Seiji; Saeki, Riuji; Toyokawa, Ryoji; Yamamoto, Kazami; Yoshimoto, Masahiro; Arakawa, Dai*; Hiramatsu, Shigenori*; Lee, S.*; Sato, Kenichiro*; et al.

Proceedings of 11th European Particle Accelerator Conference (EPAC '08) (CD-ROM), p.1125 - 1127, 2008/06

A 3-GeV Rapid-Cycling Synchrotron (RCS) of the Japan Proton Accelerator Research Complex (J-PARC) has been commissioned recently. During its beam commissioning, various beam diagnostic instrumentation has been used. The multi-wire profile monitor (MWPM) is used to establish injection and H0 dump line. The electron catcher confirms that the beam hits a charge exchange carbon foil and the specified current monitor limits the beam current to the H0 dump. Single pass BPMs and ionization profile monitors (IPM) help to check the one pass orbit without circulation of the beam. The beam position monitor (BPM) can measure both COD and turn-by-turn position. Tune monitor system consists of exciter and its own BPM. The exciter shakes the beam and coherent oscillation. Dedicated BPMs, Fast CT (FCT) and Wall Current Monitor (WCM) are used for RF feedback or feedfoward control. It will describe the performance of each instruments and how they are contributed to the successful beam commissioning.

Journal Articles

The Beam position monitor system for the J-PARC RCS

Hayashi, Naoki; Hiroki, Seiji; Saeki, Riuji; Toyokawa, Ryoji*; Yamamoto, Kazami; Arakawa, Dai*; Hiramatsu, Shigenori*; Lee, S.*; Sato, Kenichiro*; Tejima, Masaki*; et al.

Proceedings of 11th European Particle Accelerator Conference (EPAC '08) (CD-ROM), p.1128 - 1130, 2008/06

The Beam Position Monitor (BPM) system of the J-PARC RCS has been fabricated, installed and operated successfully during the beam commissioning. There are 54 BPMs around the ring and most of them are placed inside steering magnets. The BPM is electro static type and it has four electrodes. A pair of electrode gives a linear response with diagonal cut shape and they were calibrated before their installation. The signal processing unit, which is equipped with 14-bit 14MSPS ADC and 600MHz DSP, has been developed for the system. In order to measure small signal, especially during the initial phase of the commissioning, careful design also done for cabling. The paper presents the current performance of the system.

Journal Articles

The Status of the J-PARC RCS beam monitor system

Hayashi, Naoki; Hiroki, Seiji; Saha, P. K.; Saeki, Riuji; Toyokawa, Ryoji*; Yamamoto, Kazami; Yoshimoto, Masahiro; Arakawa, Dai*; Hiramatsu, Shigenori*; Lee, S.*; et al.

Proceedings of 5th Annual Meeting of Particle Accelerator Society of Japan and 33rd Linear Accelerator Meeting in Japan (CD-ROM), p.243 - 245, 2008/00

The J-PARC RCS has been beam commissioned since fall 2007. During such a short period, the following items have been established. Establishment of the injection orbit, beam circulation, acceleration up to 3GeV, optics parameters measurements and it achieved 50 kW beam power (4$$times$$10$$^{12}$$ ppb). The beam monitor system has an important role for smooth beam commissioning. This paper describes the status of the beam monitor system, BPM, Injection monitors, IPM, current monitor, tune meter and BLM of the RCS.

Journal Articles

The Beam diagnostics system for J-PARC synchrotrons

Hayashi, Naoki; Hiroki, Seiji; Sato, Kenichiro; Toyokawa, Ryoji; Arakawa, Dai*; Lee, S.*; Hashimoto, Yoshinori*; Miura, Takako*; Toyama, Takeshi*

KEK Proceedings 2006-15 (CD-ROM), p.128 - 130, 2007/03

The beam diagnostics system for J-PARC synchrotrons (RCS and MR) will be presented. The design of the system will be described for high current machines. Some test results will be reported.

Journal Articles

Development of the beam diagnostics system for the J-PARC rapid-cycling synchrotron

Hayashi, Naoki; Hiroki, Seiji; Kishiro, Junichi*; Teruyama, Yuzo*; Toyokawa, Ryoji; Arakawa, Dai*; Lee, S.*; Miura, Takako*; Toyama, Takeshi*

Proceedings of 2005 Particle Accelerator Conference (PAC '05) (CD-ROM), p.299 - 301, 2005/00

Development of the beam diagnostics system for the J-PARC (Japan Proton Accelerator Research Complex) Rapid-Cycling Synchrotron is described. The system consists of Beam Position Monitor (BPM), Beam Loss Monitor (BLM), Current monitors (DCCT, SCT, MCT, FCT, WCM), Tune meter system, 324MHz-BPM, Profile monitor, and Halo monitor. BPM electrode is electro-static type and its electronics is designed for both COD and turn-by-turn measurements. Five current monitors have different time constants in order to cover wide frequency range. The tune meter is consisted of RFKO and the beam pick-up electrode. For the continuous injected beam monitoring, 324MHz-BPM detects Linac frequency. Two types of profile monitor are multi-wire for low intensity tuning and the residual gas monitor for non-destructive measurement.

Journal Articles

Present status of the negative ion based neutral beam injector for JT-60U

Oga, Tokumichi; Umeda, Naotaka; Akino, Noboru; Ebisawa, Noboru; Grisham, L. R.*; Hikida, Shigenori*; Honda, Atsushi; Ito, Takao; Kawai, Mikito; Kazawa, Minoru; et al.

Review of Scientific Instruments, 73(2), p.1058 - 1060, 2002/02

 Times Cited Count:12 Percentile:55.36(Instruments & Instrumentation)

no abstracts in English

Journal Articles

Study of increasing the beam power on the negative ion based neutral beam injector for JT-60U

Kuriyama, Masaaki; Akino, Noboru; Ebisawa, Noboru; Grisham, L. R.*; Hikida, Shigenori*; Honda, Atsushi; Ito, Takao; Kawai, Mikito; Kazawa, Minoru; Kusaka, Makoto*; et al.

Fusion Engineering and Design, 56-57(Part.A), p.523 - 527, 2001/10

 Times Cited Count:5 Percentile:39.04(Nuclear Science & Technology)

no abstracts in English

Journal Articles

Development of negative ion based NBI system for JT-60U

Umeda, Naotaka; Akino, Noboru; Ebisawa, Noboru; Grisham, L. R.*; Hikida, Shigenori*; Honda, Atsushi; Ito, Takao; Kawai, Mikito; Kazawa, Minoru; Kusaka, Makoto*; et al.

Fusion Technology, 39(2-Part2), p.1135 - 1139, 2001/03

no abstracts in English

Journal Articles

Operation of the positive-ion based NBI system for JT-60U

Ohara, Hiroshi; Akino, Noboru; Ebisawa, Noboru; Hikida, Shigenori*; Honda, Atsushi; Ito, Takao; Kawai, Mikito; Kazawa, Minoru; Kusaka, Makoto*; Kuriyama, Masaaki; et al.

Fusion Technology, 39(2-Part2), p.1140 - 1144, 2001/03

no abstracts in English

Journal Articles

Beam performance of negative-ion based NBI system for JT-60

Ito, Takao; Akino, Noboru; Ebisawa, Noboru; Grisham, L. R.*; Honda, Atsushi; Hu, L.*; Kawai, Mikito; Kazawa, Minoru; Kuriyama, Masaaki; Kusaka, Makoto*; et al.

Fusion Engineering and Design, 51-52, p.1039 - 1047, 2000/11

 Times Cited Count:15 Percentile:68.72(Nuclear Science & Technology)

no abstracts in English

Journal Articles

Power flow in the negative-ion based neutral beam injection for JT-60

Kuriyama, Masaaki; Akino, Noboru; Ebisawa, Noboru; Grisham, L. R.*; Hikida, Shigenori*; Honda, Atsushi; Ito, Takao; Kawai, Mikito; Kazawa, Minoru; Kusaka, Makoto*; et al.

Review of Scientific Instruments, 71(2), p.751 - 754, 2000/02

 Times Cited Count:21 Percentile:72.7(Instruments & Instrumentation)

no abstracts in English

Journal Articles

Increasing the beam power of the JT-60 negative ion based neutral beam system

Kuriyama, Masaaki; Akino, Noboru; Ebisawa, Noboru; Grisham, L. R.*; Hikida, Shigenori*; Honda, Atsushi; Ito, Takao; Kawai, Mikito; Kazawa, Minoru; Kusaka, Makoto*; et al.

Proceedings of the 18th IEEE/NPSS Symposium on Fusion Engineering (SOFE '99), p.133 - 136, 1999/00

no abstracts in English

14 (Records 1-14 displayed on this page)
  • 1