Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Kataoka, Noriaki*; Tsuji, Tomoya; Takimoto, Yuki*; Kowatari, Munehiko*
Journal of Radiation Protection and Research, 51(3), p.133 - 140, 2026/09
Ba
-ray calibration field for photon energy in the 300-400 keV rangeTsuji, Tomoya; Yoshitomi, Hiroshi; Kowatari, Munehiko*; Sato, Fuminobu*; Tanimura, Yoshihiko
Radiation Protection Dosimetry, 202(8), p.619 - 630, 2026/05
Times Cited Count:0 Percentile:0.00(Environmental Sciences)Tsuji, Tomoya; Yoshitomi, Hiroshi; Sato, Fuminobu*; Tanimura, Yoshihiko
Radioisotopes, 75(S-01), p.S-004_1 - S-004_6, 2026/04
,
and
particles from grayscale radiation imagesLaffolley, H.; Tsubota, Yoichi; Tsuji, Tomoya; Honda, Fumiya
Nuclear Instruments and Methods in Physics Research A, 1082, Part 2, p.171029_1 - 171029_11, 2026/02
Times Cited Count:1 Percentile:40.19(Instruments & Instrumentation)In the framework of the decommissioning of the Fukushima Daiichi Nuclear Power Station, the Japan Atomic Energy Agency analyses and classifies a variety of radioactive samples. The objective is to simplify the sample characterization process by developing multipurpose analysis tools that quickly produce results for different types of samples while reducing labor. The development of an analytical device has been started, based on the MiniPIX TPX standard detector, a hybrid semiconductor pixelated radiation detector. This detector creates grayscale images that show the interaction of ionizing particles, where brightness directly indicates energy. The final aim is to build a fast mapping device that generates 2D activity maps, distinguishing between
,
, and
radiation, and includes simple local
spectrometry for highly contaminated samples. The shape of the cluster created by the interaction between an incident particle and the semiconductor is typical of the said particle. Thus, eight supervised machine learning models have been trained on a dataset made of 9 features extracted from pure images of
,
and
particles collected from
Co,
Sr,
Cs and
Am standard sources. The best models can distinguish the particles with nearly 80% accuracy, reaching 96% accuracy for low-energy
rays exposition only, with a processing time of a few microseconds per frame. The identification of
particles is 100% accurate.
neutron diffraction studyGong, W.; Harjo, S.; Kawasaki, Takuro; Yamashita, Takayuki*; Shibata, Akinobu*; Shinozaki, Tomoya*; Tomota, Yo*; Tsuji, Nobuhiro*
Microstructures (Internet), 5(4), p.2025087_1 - 2025087_18, 2025/12
Tsuji, Tomoya; Yoshitomi, Hiroshi; Nishino, Sho; Sato, Fuminobu*; Tanimura, Yoshihiko
Journal of Radiological Protection, 45(3), p.031519_1 - 031519_8, 2025/09
Times Cited Count:0 Percentile:0.00(Environmental Sciences)Kowatari, Munehiko*; Nakagami, Koichi*; Hijikata, Yasukazu*; Yamashita, Kazuta*; Hirai, Yuta*; Matsuzaki, Satoru*; Moritake, Takashi*; Tsuji, Tomoya; Zutz, H.*; Ketelhut, S.*; et al.
Radiation Protection Dosimetry, 201(9), p.663 - 671, 2025/06
Times Cited Count:0 Percentile:0.00(Environmental Sciences)Tsuji, Tomoya; Yoshitomi, Hiroshi; Sato, Fuminobu*; Tanimura, Yoshihiko
Radiation Protection Dosimetry, 201(9), p.648 - 662, 2025/06
Times Cited Count:3 Percentile:76.24(Environmental Sciences)Ishii, Junya*; Shimizu, Morihito*; Kato, Masahiro*; Kurosawa, Tadahiro*; Tsuji, Tomoya; Yoshitomi, Hiroshi; Tanimura, Yoshihiko; Watabe, Hiroshi*
Journal of Radiological Protection, 44(3), p.031516_1 - 031516_8, 2024/09
Times Cited Count:0 Percentile:0.00(Environmental Sciences)
Am gamma calibration field based on international standards and its conversion coefficientsTsuji, Tomoya; Yoshitomi, Hiroshi; Kowatari, Munehiko*; Tanimura, Yoshihiko
Radiation Protection Dosimetry, 200(15), p.1416 - 1424, 2024/09
Times Cited Count:5 Percentile:68.78(Environmental Sciences)Tanimura, Yoshihiko; Yoshitomi, Hiroshi; Nishino, Sho; Tsuji, Tomoya; Fukami, Tomoyo; Shinozuka, Tomoki; Oishi, Kohei; Ishii, Masato; Takamiya, Kei; Onuki, Takaya; et al.
Radiation Measurements, 176, p.107196_1 - 107196_6, 2024/08
Times Cited Count:1 Percentile:16.94(Nuclear Science & Technology)The ICRU has proposed to change the definitions of the operational quantities used for the area and individual monitoring for external exposure in the ICRU Report 95. As introducing the new operational quantities into the radiation monitoring may affect the dose assessment results using the present personal dosimeters, it is necessary to characterize the energy spectrum in the workplace and the energy dependency of the dosimeters to be used. In this work the photon spectra were measured using a NaI(Tl) scintillation detector or a LaBr
(Ce) scintillation detector at the workplaces in the Japanese Research Reactor No.3 (JRR-3) and the Japan Proton Accelerator Research Complex (J-PARC) at Japan Atomic Energy Agency (JAEA). Then the present and new operational quantities were evaluated using the above mention spectra at the workplaces and compared each other.
Yomogida, Takumi; Hashimoto, Tadashi; Okumura, Takuma*; Yamada, Shinya*; Tatsuno, Hideyuki*; Noda, Hirofumi*; Hayakawa, Ryota*; Okada, Shinji*; Takatori, Sayuri*; Isobe, Tadaaki*; et al.
Analyst, 149(10), p.2932 - 2941, 2024/03
Times Cited Count:5 Percentile:44.37(Chemistry, Analytical)In this study, we successfully applied a transition-edge sensor (TES) spectrometer as a detector for microbeam X-ray measurements from a synchrotron X-ray light source to determine uranium (U) distribution at the micro-scale and its chemical species in biotite obtained from the U mine. It is difficult to separate the fluorescent X-ray of the U L
line at 13.615 keV from that of the Rb K
line at 13.395 keV in the X-ray fluorescence spectrum with an energy resolution of approximately 220 eV of the conventional silicon drift detector (SDD). Meanwhile, the fluorescent X-rays of U L
and Rb K
were fully separated by TES with 50 eV energy resolution at the energy of around 13 keV. The successful peak separation by TES led to an accurate mapping analysis of trace U in micro-X-ray fluorescence measurements and a decrease in the signal-to-background ratio in micro-X-ray absorption near edge structure spectroscopy.
Nakajima, Junya; Hirota, Seiko*; Tsuji, Tomoya; Watanabe, Yuki; Sakoda, Akihiro; Kobayashi, Noriko*
Hoken Butsuri (Internet), 58(1), p.13 - 20, 2023/04
no abstracts in English
Yasuoka, Yumi*; Fujita, Hiroki; Tsuji, Tomoya; Tsujiguchi, Takakiyo*; Sasaki, Michiya*; Miyazaki, Tomoyuki*; Hashima, Shun*; Yasuda, Hiroshi*; Shimada, Kazumasa; Hirota, Seiko*
Hoken Butsuri (Internet), 57(3), p.146 - 155, 2022/12
no abstracts in English
Sakoda, Akihiro; Tsuji, Tomoya; Hirota, Seiko*; Watanabe, Yuki
Hoken Butsuri (Internet), 57(2), p.108 - 114, 2022/06
no abstracts in English
Watanabe, Yuki; Tsuji, Tomoya; Hirota, Seiko*; Hokama, Tomonori; Nakajima, Junya; Tsujiguchi, Takakiyo*; Kimura, Tatsuki*; Koike, Hiromi*; Nakamura, Kaori*; Kuwata, Haruka*; et al.
Hoken Butsuri (Internet), 57(1), p.54 - 64, 2022/03
no abstracts in English
Yamada, Ryohei; Kono, Takahiko; Nakajima, Junya; Hirouchi, Jun; Tsuji, Tomoya; Umeda, Masayuki; Igarashi, Yu*; Koike, Hiromi*
Hoken Butsuri (Internet), 56(1), p.32 - 38, 2021/03
no abstracts in English
Kawasaki, Masatsugu; Nakajima, Junya; Yoshida, Keisuke; Kato, Saori; Nishino, Sho; Nozaki, Teo; Nakagawa, Masahiro; Tsunoda, Junichi; Sugaya, Yuki; Hasegawa, Rie; et al.
JAEA-Data/Code 2017-004, 57 Pages, 2017/03
In emergency situation of nuclear facilities, we need to estimate the radiation dose due to radiation and radioactivity to grasp the influence range of the accident in the early stage. Therefore, we prepare the case studies of dose assessment for public exposure dose and personal exposure dose and contribute them to emergency procedures. This document covers about accidents of nuclear facilities in Nuclear Science Research Institute and past accident of nuclear power plant, and it can be used for inheritance of techniques of emergency dose assessment.
Sasaki, Yuji; Kitatsuji, Yoshihiro; Sugo, Yumi; Tsubata, Yasuhiro; Suzuki, Tomoya; Kimura, Takaumi; Morita, Yasuji
Proceedings of 20th International Solvent Extraction Conference (ISEC 2014), p.431 - 435, 2014/09
The eight amide extractants including podand-types, which introduce oxygen, nitrogen and sulfur donor atoms in their central frame, are synthesized and their D values for actinide extraction are compared. The central frame affect greatly on their extractability and it is clear that diglycolamide (DGA) has the highest extractability among extractants used here. In addition, DGA having the different length of alkyl chain or phenyl groups attached to amidic N atoms are obtained and the effect of these substituents is studied. Due to the steric hindrance or hydrogen bond, DGA with long and branched alkyl chains, phenyl group, and proton give relatively low D values.
Sasaki, Yuji; Tsubata, Yasuhiro; Kitatsuji, Yoshihiro; Sugo, Yumi; Shirasu, Noriko; Ikeda, Yasuhisa*; Kawasaki, Takeshi*; Suzuki, Tomoya*; Mimura, Hitoshi*; Usuda, Shigekazu*; et al.
JAEA-Research 2014-008, 220 Pages, 2014/06
The researches on Development of mutual separation technology of minor actinides by the novel hydrophilic and lipophilic diamide compounds, entrusted to Japan Atomic Energy Agency by the Ministry of Education, Culture, Sports, Science and Technology of Japan, from 2010 to 2012 are summarized. This project was composed of three themes, those are (1) Development of total recovery of MA+Ln: basic researches for new extractant, DOODA, (2) Development of mutual separation of Am/Cm/Ln: basic researches of Ln-complex, solvent extraction, and extraction chromatography, and (3) Evaluation of separation technique: process simulation. For topic (1), we summarized the information on characteristic of DOODA extractant. For topic (2), we summarized the information on structures of Ln-complexes, solvent extraction and chromatography. For topic (3), we summarized the information on conditions of mixer-settler and evaluation of each fraction separated.