Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 145

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Improvement of the hybrid approach between Monte Carlo simulation and analytical function for calculating microdosimetric probability densities in macroscopic matter

Sato, Tatsuhiko; Matsuya, Yusuke*; Ogawa, Tatsuhiko; Kai, Takeshi; Hirata, Yuho; Tsuda, Shuichi; Parisi, A.*

Physics in Medicine & Biology, 68(15), p.155005_1 - 155005_15, 2023/07

 Times Cited Count:2 Percentile:84.52(Engineering, Biomedical)

In this study, we improved the microdosimetric function implemented in PHITS using the latest track-structure simulation codes. The improved function is capable of calculating the probability densities of not only the conventional microdosimetric quantities such as lineal energy but also the numbers of ionization events occurred in a target site, the so-called ionization cluster size distribution, for arbitrary site diameters from 3 nm to 1 um. As a new application of the improved function, we calculated the relative biological effectiveness of the single-strand break and double-strand break yields for proton irradiations using the updated PHITS coupled with the simplified DNA damage estimation model, and confirmed its equivalence in accuracy and its superiority in computational time compared to our previously proposed method based on the track-structure simulation.

Journal Articles

Benchmark shielding calculations for fusion and accelerator-driven sub-critical systems

Iwamoto, Yosuke; Tsuda, Shuichi; Ogawa, Tatsuhiko

Frontiers in Energy Research (Internet), 11, p.1085264_1 - 1085264_11, 2023/01

 Times Cited Count:0 Percentile:0.02(Energy & Fuels)

This review describes experimental data useful for validation of radiation shielding design in advanced reactor systems such as nuclear fusion and accelerator-driven subcritical systems (ADS) and calculations using the PHITS code and JENDL-4.0/HE. The relevant experiments have been conducted mainly in Japan and include (1) neutron spectra in iron shields using 14 MeV neutron sources, (2) leakage neutron spectra from spherical piles of various materials using 14 MeV neutron sources, (3) neutron spectra after penetration through shields using several tens of MeV neutron sources, (4) neutron spectra produced from the target by high-energy heavy-ion bombardment, and (5) induced radioactivity in concrete using heavy-ion nuclear reaction product particles as a source. Throughout, the experimental and calculated values were agreed well. These experimental data are also useful for the validation of all radiation transport calculation codes used in the design of advanced reactor systems.

Journal Articles

Recent improvements of the Particle and Heavy Ion Transport code System; PHITS version 3.33

Sato, Tatsuhiko; Iwamoto, Yosuke; Hashimoto, Shintaro; Ogawa, Tatsuhiko; Furuta, Takuya; Abe, Shinichiro; Kai, Takeshi; Matsuya, Yusuke; Matsuda, Norihiro; Hirata, Yuho; et al.

Journal of Nuclear Science and Technology, 9 Pages, 2023/00

 Times Cited Count:5 Percentile:98.08(Nuclear Science & Technology)

The Particle and Heavy Ion Transport code System (PHITS) is a general-purpose Monte Carlo radiation transport code that can simulate the behavior of most particle species with energies up to 1 TeV (per nucleon for ions). Its new version, PHITS3.31, was recently developed and released to the public. In the new version, the compatibility with high-energy nuclear data libraries and the algorithm of the track-structure modes have been improved. In this paper, we summarize the upgraded features of PHITS3.31 with respect to the physics models, utility functions, and application software introduced since the release of PHITS3.02 in 2017.

Journal Articles

Mesospheric ionization during substorm growth phase

Murase, Kiyoka*; Kataoka, Ryuho*; Nishiyama, Takanori*; Nishimura, Koji*; Hashimoto, Taishi*; Tanaka, Yoshimasa*; Kadokura, Akira*; Tomikawa, Yoshihiro*; Tsutsumi, Masaki*; Ogawa, Yasunobu*; et al.

Journal of Space Weather and Space Climate (Internet), 12, p.18_1 - 18_16, 2022/06

 Times Cited Count:1 Percentile:22.72(Astronomy & Astrophysics)

We identified two energetic electron precipitation (EEP) events during the growth phase of moderate substorms and estimated the mesospheric ionization rate for an EEP event for which the most comprehensive dataset from ground-based and space-born instruments was available. The mesospheric ionization signature reached below 70 km altitude and continued for ~15 min until the substorm onset, as observed by the PANSY radar and imaging riometer at Syowa Station in the Antarctic region. We also used energetic electron flux observed by the Arase and POES 15 satellites as the input for the air-shower simulation code PHITS to quantitatively estimate the mesospheric ionization rate. Combining the cutting-edge observations and simulations, we shed new light on the space weather impact of the EEP events during geomagnetically quiet times, which is important to understand the possible link between the space environment and climate.

Journal Articles

Benchmark study of particle and heavy-ion transport code system using shielding integral benchmark archive and database for accelerator-shielding experiments

Iwamoto, Yosuke; Hashimoto, Shintaro; Sato, Tatsuhiko; Matsuda, Norihiro; Kunieda, Satoshi; $c{C}$elik, Y.*; Furutachi, Naoya*; Niita, Koji*

Journal of Nuclear Science and Technology, 59(5), p.665 - 675, 2022/05

 Times Cited Count:8 Percentile:81.24(Nuclear Science & Technology)

A benchmark study of PHITS3.24 has been conducted using neutron-shielding experiments listed in the Shielding Integral Benchmark Archive and Database. Five neutron sources were selected, which are generated from (1) 43- and 68-MeV proton-induced reaction on a thin lithium target, (2) 52-MeV proton-induced reaction on a thick graphite target, (3) 590-MeV proton-induced reaction on a thick lead target, (4) 500-MeV proton-induced reaction on a thick tungsten target, and (5) 800-MeV proton-induced reaction on a thick tantalum target. For all cases, overall agreements in the results are satisfactory when using the JENDL-4.0/HE to simulate neutron- and proton-induced reactions up to 200 MeV. However, discrepancies using PHITS default settings are observed in the results. For an accurate neutron-shielding design for accelerator facilities, using JENDL-4.0/HE in the particle and heavy-ion transport code system calculation is favorable.

Journal Articles

Modernization of the DCHAIN-PHITS activation code with new features and updated data libraries

Ratliff, H.; Matsuda, Norihiro; Abe, Shinichiro; Miura, Takamitsu*; Furuta, Takuya; Iwamoto, Yosuke; Sato, Tatsuhiko

Nuclear Instruments and Methods in Physics Research B, 484, p.29 - 41, 2020/12

 Times Cited Count:11 Percentile:82.11(Instruments & Instrumentation)

Journal Articles

Cathodoluminescence of cerium dioxide; Combined effects of the electron beam energy and sample temperature

Constantini, J.-M.*; Seo, P.*; Yasuda, Kazuhiro*; Bhuian, AKM S. I.*; Ogawa, Tatsuhiko; Gourier, D.*

Journal of Luminescence, 226, p.117379_1 - 117379_10, 2020/10

 Times Cited Count:5 Percentile:42.02(Optics)

Cathodo-luminescence is used for detection of lattice defects, in particular oxygen vacancies in ceramics induced by electrons. However, how oxygen vacancy production efficiency depends on sample temperature, incoming electron flux, and electron energy was not clear. In this study, oxygen vacancies were made in the specimens of CeO$$_{2}$$ by irradiation of 400-1250 keV electrons and the cathodoluminescence from thus induced vacancies were observed by photo-fiber probe combined with CCD. As the result, the dependence of luminescence intensity on specimen temperature depends on the carrier trapping frequency and luminescence efficiency while luminescence center production/annihilation speed determines the dependency on the incoming electron flux. Moreover, radiation transport calculation conducted by the particle transport simulation code PHITS indicates that the number of electrons above the defect production threshold energy is vital to explain incoming electron energy dependence.

Journal Articles

Investigation of using a long-life electronic personal dosimeter for monitoring aviation doses of frequent flyers

Yasuda, Hiroshi*; Yajima, Kazuaki*; Sato, Tatsuhiko

Radiation Measurements, 134, p.106309_1 - 106309_4, 2020/06

 Times Cited Count:8 Percentile:60.71(Nuclear Science & Technology)

We have investigated an application of a recently developed electronic personal dosimeter (D-Shuttle) for aviation dosimetry. As results of measurements in four long-haul flights between Japan and Germany, the D-Shuttle indicated values were in the range of 25 to 30% of the total H$$^{*}$$(10) values estimated by a route-dose calculations program JISCARD EX. Though we need more measurements and analyses under different flight conditions to conclude, according to these results obtained so far, it would be possible to perform monitoring of the annual aviation doses of frequent flyers by using D-Shuttle on an individual basis.

Journal Articles

Transient ionization of the mesosphere during auroral breakup; Arase satellite and ground-based conjugate observations at Syowa Station

Kataoka, Ryuho*; Nishiyama, Takanori*; Tanaka, Yoshimasa*; Kadokura, Akira*; Uchida, Herbert Akihito*; Ebihara, Yusuke*; Ejiri, Mitsumu*; Tomikawa, Yoshihiro*; Tsutsumi, Masaki*; Sato, Kaoru*; et al.

Earth, Planets and Space (Internet), 71(1), p.9_1 - 9_10, 2019/12

 Times Cited Count:8 Percentile:40.25(Geosciences, Multidisciplinary)

Transient ionization of the mesosphere was detected at around 65 km altitude during the isolated auroral expansion occurred at 2221-2226 UT on June 30, 2017. A general-purpose Monte Carlo particle transport code PHITS suggested that significant ionization is possible in the middle atmosphere due to auroral X-rays from the auroral electrons of $$<$$10 keV.

Journal Articles

Cathodoluminescence induced in oxides by high-energy electrons; Effects of beam flux, electron energy, and temperature

Constantini, J.-M.*; Ogawa, Tatsuhiko; Bhuian, A. S. I.*; Yasuda, Kazuhiro*

Journal of Luminescence, 208, p.108 - 118, 2019/04

 Times Cited Count:4 Percentile:30.7(Optics)

Cathodo-luminescence is used for detection of lattice defects, in particular oxygen vacancies in ceramics induced by electrons. However, how oxygen vacancy production efficiency depends on sample temperature, incoming electron flux, and electron energy was not clear. In this study, oxygen vacancies were made in the specimens of Al$$_{2}$$O$$_{3}$$, ZrO$$_{2}$$:Y(Yttrium stabilized zirconia), MgAl$$_{2}$$O$$_{4}$$, and TiO$$_{2}$$ by irradiation of 400-1250keV electrons and the cathodoluminescence from thus induced vacancies were observed by photo-fiber probe combined with CCD. As the result, the dependence of luminescence intensity on specimen temperature depends on the carrier trapping frequency and luminescence efficiency while luminescence center production/annihilation speed determines the dependency on the incoming electron flux. Moreover, radiation transport calculation conducted by the particle transport simulation code PHITS indicates that the number of electrons above the defect production threshold energy is vital to explain incoming electron energy dependence.

Journal Articles

Nowcast and forecast of galactic cosmic ray (GCR) and solar energetic particle (SEP) fluxes in magnetosphere and ionosphere; Extension of WASAVIES to earth orbit

Sato, Tatsuhiko; Kataoka, Ryuho*; Shiota, Daiko*; Kubo, Yuki*; Ishii, Mamoru*; Yasuda, Hiroshi*; Miyake, Shoko*; Miyoshi, Yoshizumi*; Ueno, Haruka*; Nagamatsu, Aiko*

Journal of Space Weather and Space Climate (Internet), 9, p.A9_1 - A9_11, 2019/03

 Times Cited Count:7 Percentile:38.79(Astronomy & Astrophysics)

Real-time estimation of astronaut doses during solar particle events (SPE) is one of the most challenging tasks in cosmic-ray dosimetry. We therefore develop a new computational method that can nowcast the solar energetic particle (SEP) as well as galactic cosmic-ray (GCR) fluxes on any Earth orbit during a large SPE associating with ground level enhancement. It is an extended version of WArning System for AVIation Exposure to Solar Energetic Particle, WASAVIES. The extended version, called WASAVIES-EO, can calculate the GCR and SEP fluxes outside a satellite based on its two-line element data. Moreover, organ dose and dose-equivalent rates of astronauts in the International Space Station (ISS) can be estimated using the system, considering its shielding effect. The accuracy of WASAVIES-EO was validated based on the dose rates measured in ISS, as well as based on high-energy proton fluxes observed by POES satellites.

Journal Articles

Real time and automatic analysis program for WASAVIES; Warning system for aviation exposure to solar energetic particles

Sato, Tatsuhiko; Kataoka, Ryuho*; Shiota, Daiko*; Kubo, Yuki*; Ishii, Mamoru*; Yasuda, Hiroshi*; Miyake, Shoko*; Park, I.*; Miyoshi, Yoshizumi*

Space Weather, 16(7), p.924 - 936, 2018/07

 Times Cited Count:19 Percentile:69.84(Astronomy & Astrophysics)

A physics-based warning system of aviation exposure to solar energetic particles, WASAVIES, is improved to be capable of real-time and automatic analysis. In the improved system, the count rates of several neutron monitors (NM) at the ground level, as well as the proton fluxes measured by the GOES satellite are continuously downloaded at intervals of 5 min and used for determining the model parameters. The performance of WASAVIES is examined by analyzing the three major GLE events of the 21st century. A web-interface of WASAVIES is also developed and will be released in the near future through the public server of NICT.

Journal Articles

Features of particle and heavy ion transport code system (PHITS) version 3.02

Sato, Tatsuhiko; Iwamoto, Yosuke; Hashimoto, Shintaro; Ogawa, Tatsuhiko; Furuta, Takuya; Abe, Shinichiro; Kai, Takeshi; Tsai, P.-E.; Matsuda, Norihiro; Iwase, Hiroshi*; et al.

Journal of Nuclear Science and Technology, 55(6), p.684 - 690, 2018/06

 Times Cited Count:775 Percentile:100(Nuclear Science & Technology)

We have upgraded many features of the Particle and Heavy Ion Transport code System (PHITS) and released the new version as PHITS3.02. The accuracy and the applicable energy ranges of the code were greatly improved and extended, respectively, owing to the revisions to the nuclear reaction models and the incorporation of new atomic interaction models. In addition, several user-supportive functions were developed, such as new tallies to efficiently obtain statistically better results, radioisotope source-generation function, and software tools useful for applying PHITS to medical physics. In this paper, we summarize the basic features of PHITS3.02, especially those of the physics models and the functions implemented after the release of PHITS2.52 in 2013.

Journal Articles

Experimental analysis of neutron and background $$gamma$$-ray energy spectra of 80-400 MeV $$^{7}$$Li(p,n) reactions under the quasi-monoenergetic neutron field at RCNP, Osaka University

Iwamoto, Yosuke; Sato, Tatsuhiko; Satoh, Daiki; Hagiwara, Masayuki*; Yashima, Hiroshi*; Masuda, Akihiko*; Matsumoto, Tetsuro*; Iwase, Hiroshi*; Shima, Tatsushi*; Nakamura, Takashi*

EPJ Web of Conferences, 153, p.08019_1 - 08019_3, 2017/09

 Times Cited Count:0 Percentile:0.03(Nuclear Science & Technology)

To develop 100-400 MeV quasi-monoenergetic neutron field, we measured neutron and unexpected $$gamma$$-ray energy spectra of the $$^{7}$$Li(p,n) reaction with 80-389 MeV protons in the 100-m time-of-flight (TOF) tunnel at the Research Center for Nuclear Physics (RCNP). Neutron energy spectra with energies above 3 MeV were measured by the TOF method and $$gamma$$ energy spectra with energies above 0.1 MeV were measured by the automatic unfolding function of the radiation dose monitor DARWIN. For neutron spectra, the contribution of peak intensity to the total intensity integrated with energies above 3 MeV varied between 0.38 and 0.48. For $$gamma$$-ray spectra, high-energetic $$gamma$$-rays at around 70 MeV originated from the decay of $$pi$$$$^{0}$$ were observed over 200 MeV. For the 246-MeV proton incident reaction, the contribution of $$gamma$$-ray dose to neutron dose is negligible because the ratio of $$gamma$$-ray to neutron is 0.014.

Journal Articles

Characterization of the PTW 34031 ionization chamber (PMI) at RCNP with high energy neutrons ranging from 100 - 392 MeV

Theis, C.*; Carbonez, P.*; Feldbaumer, E.*; Forkel-Wirth, D.*; Jaegerhofer, L.*; Pangallo, M.*; Perrin, D.*; Urscheler, C.*; Roesler, S.*; Vincke, H.*; et al.

EPJ Web of Conferences, 153, p.08018_1 - 08018_5, 2017/09

 Times Cited Count:0 Percentile:0.03(Nuclear Science & Technology)

At CERN, gas-filled ionization chambers PTW-34031 (PMI) are commonly used in radiation fields including neutrons, protons and $$gamma$$-rays. A response function for each particle is calculated by the radiation transport code FLUKA. To validate a response function to high energy neutrons, benchmark experiments with quasi mono-energetic neutrons have been carried out at RCNP, Osaka University. For neutron irradiation with energies below 200 MeV, very good agreement was found comparing the FLUKA simulations and the measurements. In addition it was found that at proton energies of 250 and 392 MeV, results calculated with neutron sources underestimate the experimental data due to a non-negligible gamma component originating from the target $$^{7}$$Li(p,n)Be reaction.

Journal Articles

Recent improvements of particle and heavy ion transport code system: PHITS

Sato, Tatsuhiko; Niita, Koji*; Iwamoto, Yosuke; Hashimoto, Shintaro; Ogawa, Tatsuhiko; Furuta, Takuya; Abe, Shinichiro; Kai, Takeshi; Matsuda, Norihiro; Okumura, Keisuke; et al.

EPJ Web of Conferences, 153, p.06008_1 - 06008_6, 2017/09

 Times Cited Count:6 Percentile:95.25(Nuclear Science & Technology)

Particle and Heavy Ion Transport code System, PHITS, has been developed under the collaboration of several institutes in Japan and Europe. It can deal with the transport of nearly all particles up to 1 TeV (per nucleon for ion) using various nuclear reaction models and data libraries. More than 2,500 researchers and technicians have used the code for a variety of applications such as accelerator design, radiation shielding and protection, medical physics, and space and geosciences. This paper briefly summarizes physics models and functions newly implemented in PHITS between versions 2.52 and 2.82.

Journal Articles

Features of PHITS version 2.88

Sato, Tatsuhiko; Iwamoto, Yosuke; Hashimoto, Shintaro; Ogawa, Tatsuhiko; Furuta, Takuya; Abe, Shinichiro; Kai, Takeshi; Matsuda, Norihiro; Iwase, Hiroshi*; Niita, Koji*

Hoshasen, 43(2), p.55 - 58, 2017/05

Particle and Heavy Ion Transport code System, PHITS, has been developed under the collaboration of several institutes in Japan and Europe. It can deal with the transport of nearly all particles up to 1 TeV (per nucleon for ion) using various nuclear reaction models and data libraries. More than 2,500 registered researchers and technicians have used this system for various applications such as accelerator design, radiation shielding and protection, medical physics, and space- and geo-sciences. This paper summarizes the physics models and functions recently implemented in PHITS, between versions 2.52 and 2.88.

Journal Articles

Benchmark study of the recent version of the PHITS code

Iwamoto, Yosuke; Sato, Tatsuhiko; Hashimoto, Shintaro; Ogawa, Tatsuhiko; Furuta, Takuya; Abe, Shinichiro; Kai, Takeshi; Matsuda, Norihiro; Hosoyamada, Ryuji*; Niita, Koji*

Journal of Nuclear Science and Technology, 54(5), p.617 - 635, 2017/05

 Times Cited Count:96 Percentile:99.72(Nuclear Science & Technology)

We performed a benchmark study for 58 cases using the recent version 2.88 of the Particle and Heavy Ion Transport code System (PHITS) in the following fields: particle production cross-sections for nuclear reactions, neutron transport calculations, and electro-magnetic cascade. This paper reports details for 22 cases. In cases of nuclear reactions with energies above 100 MeV and electro-magnetic cascade, overall agreements were found to be satisfactory. On the other hand, PHITS did not reproduce the experimental data for an incident proton energy below 100 MeV, because the intranuclear cascade model INCL4.6 in PHITS is not suitable for the low-energy region. For proton incident reactions over 100 MeV, PHITS did not reproduce fission product yields due to the problem of high-energy fission process in the evaporation model GEM. To overcome these inaccuracies, we are planning to incorporate a high-energy version of the evaluated nuclear data library JENDL-4.0/HE, and so on.

Journal Articles

Applicability of the two-angle differential method to response measurement of neutron-sensitive devices at the RCNP high-energy neutron facility

Masuda, Akihiko*; Matsumoto, Tetsuro*; Iwamoto, Yosuke; Hagiwara, Masayuki*; Satoh, Daiki; Sato, Tatsuhiko; Iwase, Hiroshi*; Yashima, Hiroshi*; Nakane, Yoshihiro; Nishiyama, Jun*; et al.

Nuclear Instruments and Methods in Physics Research A, 849, p.94 - 101, 2017/03

 Times Cited Count:1 Percentile:10.62(Instruments & Instrumentation)

Quasi-monoenergetic high-energy neutron fields induced by $$^{7}$$Li(p,n) reactions are used for the response evaluation of neutron-sensitive devices. The quasi-monoenergetic high-energy field consists of high-energy monoenergetic peak neutrons and unwanted continuum neutrons down to the low-energy region. A two-angle differential method has been developed to compensate for the effect of the continuum neutrons in the response measurements. In this study, the two-angle differential method was demonstrated for Bonner sphere detectors, which are typical examples of moderator-based neutron-sensitive detectors, to investigate the method's applicability and its dependence on detector characteristics. Through this study, the adequacy of the two-angle differential method was experimentally verified, and practical suggestions were made pertaining to this method.

Journal Articles

Review of the microdosimetric studies for high-energy charged particle beams using a tissue-equivalent proportional counter

Tsuda, Shuichi; Sato, Tatsuhiko; Ogawa, Tatsuhiko; Sasaki, Shinichi*

JPS Conference Proceedings (Internet), 11, p.060004_1 - 060004_6, 2016/11

Track structure and energy deposition around charged particle beams in microscopic site of a living cell is important information for understanding of biological effects of energetic heavy ion beams. In this work, measurements of lineal energy ($$y$$) distributions for various kinds of ion beams have been performed for the verification of the microdosimetric function that incorporated in the PHITS code. In the international symposium focused on radiation detectors, the wall-less tissue equivalent proportional counter that developed in this study to measure $$y$$ distributions will be introduced, together with a series of data.

145 (Records 1-20 displayed on this page)