Refine your search:     
Report No.
 - 
Search Results: Records 1-11 displayed on this page of 11
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Interlaboratory comparison of electron paramagnetic resonance tooth enamel dosimetry with investigations of the dose responses of the standard samples

Toyoda, Shin*; Inoue, Kazuhiko*; Yamaguchi, Ichiro*; Hoshi, Masaharu*; Hirota, Seiko*; Oka, Toshitaka; Shimazaki, Tatsuya*; Mizuno, Hideyuki*; Tani, Atsushi*; Yasuda, Hiroshi*; et al.

Radiation Protection Dosimetry, 199(14), p.1557 - 1564, 2023/09

 Times Cited Count:0 Percentile:0.01(Environmental Sciences)

Interlaboratory comparison studies are important for radiation dosimetry in order to demonstrate how the technique is universally available. The set of standard samples are examined in each participating laboratory in the present study. After a set of standard samples together with the samples with unknown doses, which were prepared in the same laboratory as the standard samples, are measured at a participating laboratory, those samples are sent to another participating laboratory for next measurement. There is some small difference observed in the sensitivity (the slope of the dose response line) of the standard samples while the differences in the obtained doses for the samples with unknown doses are rather systematic, implying that the difference is mostly due to the samples but not to measurements.

Journal Articles

Science from the initial operation of HRC

Ito, Shinichi*; Yokoo, Tetsuya*; Masuda, Takatsugu*; Yoshizawa, Hideki*; Soda, Minoru*; Ikeda, Yoichi*; Ibuka, Soshi*; Kawana, Daichi*; Sato, Taku*; Nambu, Yusuke*; et al.

JPS Conference Proceedings (Internet), 8, p.034001_1 - 034001_6, 2015/09

JAEA Reports

Conceptual design of multipurpose compact research reactor; Annual report FY2010 (Joint research)

Imaizumi, Tomomi; Miyauchi, Masaru; Ito, Masayasu; Watahiki, Shunsuke; Nagata, Hiroshi; Hanakawa, Hiroki; Naka, Michihiro; Kawamata, Kazuo; Yamaura, Takayuki; Ide, Hiroshi; et al.

JAEA-Technology 2011-031, 123 Pages, 2012/01

JAEA-Technology-2011-031.pdf:16.08MB

The number of research reactors in the world is decreasing because of their aging. However, the planning to introduce the nuclear power plants is increasing in Asian countries. In these Asian countries, the key issue is the human resource development for operation and management of nuclear power plants after constructed them, and also the necessity of research reactor, which is used for lifetime extension of LWRs, progress of the science and technology, expansion of industry use, human resources training and so on, is increasing. From above backgrounds, the Neutron Irradiation and Testing Reactor Center began to discuss basic concept of a multipurpose low-power research reactor for education and training, etc. This design study is expected to contribute not only to design tool improvement and human resources development in the Neutron Irradiation and Testing Reactor Center but also to maintain and upgrade the technology on research reactors in nuclear power-related companies. This report treats the activities of the working group from July 2010 to June 2011 on the multipurpose low-power research reactor in the Neutron Irradiation and Testing Reactor Center and nuclear power-related companies.

Journal Articles

The H-Invitational Database (H-InvDB); A Comprehensive annotation resource for human genes and transcripts

Yamasaki, Chisato*; Murakami, Katsuhiko*; Fujii, Yasuyuki*; Sato, Yoshiharu*; Harada, Erimi*; Takeda, Junichi*; Taniya, Takayuki*; Sakate, Ryuichi*; Kikugawa, Shingo*; Shimada, Makoto*; et al.

Nucleic Acids Research, 36(Database), p.D793 - D799, 2008/01

 Times Cited Count:51 Percentile:71.25(Biochemistry & Molecular Biology)

Here we report the new features and improvements in our latest release of the H-Invitational Database, a comprehensive annotation resource for human genes and transcripts. H-InvDB, originally developed as an integrated database of the human transcriptome based on extensive annotation of large sets of fulllength cDNA (FLcDNA) clones, now provides annotation for 120 558 human mRNAs extracted from the International Nucleotide Sequence Databases (INSD), in addition to 54 978 human FLcDNAs, in the latest release H-InvDB. We mapped those human transcripts onto the human genome sequences (NCBI build 36.1) and determined 34 699 human gene clusters, which could define 34 057 protein-coding and 642 non-protein-coding loci; 858 transcribed loci overlapped with predicted pseudogenes.

Journal Articles

Development Method to Estimate the Complex Index of Refraction of Dielectric Aerosols

Kudo, Kazuhiko*; Li, H.*; Li, B.-X.*; Saito, Jun*; Yamaguchi, Akira; Takata, Takashi

JSME International Journal, Series B, 47(3), p.631 - 636, 2004/08

A method to estimate complex refractive index of dielectric aerosols is developed. For the purpose, three-dimensional radiative transfer problem in an absorbing-scattering media is solved by the Monte Carlo method. The Mie.s scattering theory is used to handle particle scattering and absorption. Magnesium oxide aerosol, whose complex index of refraction is well known, is selected as the example of the dielectric aerosol. Magnesium is burnt to produce MgO aerosol and the transmission of the radiation from a black body furnace through the aerosol layer is measured. By comparing the analytical results of transmitted energy profile along the wall facing the emission resource, black body furnace, obtained for a wide range of the complex index of refraction, with the experimental results, it is shown that the value of the complex refractive index of the aerosol can be estimated.

JAEA Reports

Journal Articles

Beam performance of negative-ion based NBI system for JT-60

Ito, Takao; Akino, Noboru; Ebisawa, Noboru; Grisham, L. R.*; Honda, Atsushi; Hu, L.*; Kawai, Mikito; Kazawa, Minoru; Kuriyama, Masaaki; Kusaka, Makoto*; et al.

Fusion Engineering and Design, 51-52, p.1039 - 1047, 2000/11

 Times Cited Count:15 Percentile:68.65(Nuclear Science & Technology)

no abstracts in English

Journal Articles

Power flow in the negative-ion based neutral beam injection for JT-60

Kuriyama, Masaaki; Akino, Noboru; Ebisawa, Noboru; Grisham, L. R.*; Hikida, Shigenori*; Honda, Atsushi; Ito, Takao; Kawai, Mikito; Kazawa, Minoru; Kusaka, Makoto*; et al.

Review of Scientific Instruments, 71(2), p.751 - 754, 2000/02

 Times Cited Count:21 Percentile:72.69(Instruments & Instrumentation)

no abstracts in English

Journal Articles

Increasing the beam power of the JT-60 negative ion based neutral beam system

Kuriyama, Masaaki; Akino, Noboru; Ebisawa, Noboru; Grisham, L. R.*; Hikida, Shigenori*; Honda, Atsushi; Ito, Takao; Kawai, Mikito; Kazawa, Minoru; Kusaka, Makoto*; et al.

Proceedings of the 18th IEEE/NPSS Symposium on Fusion Engineering (SOFE '99), p.133 - 136, 1999/00

no abstracts in English

Oral presentation

Conceptual design of next generation MTR

Nagata, Hiroshi; Yamaura, Takayuki; Naka, Michihiro; Kawamata, Kazuo; Izumo, Hironobu; Hori, Naohiko; Nagao, Yoshiharu; Kusunoki, Tsuyoshi; Kaminaga, Masanori; Komori, Yoshihiro; et al.

no journal, , 

Conceptual design of the high-performance and low-cost next generation materials testing reactor which will be assumed to introduce to the nuclear power plant introduction country started from 2010 in the JAEA. Japanese atomic energy-related companies participate in this project, and this activity role as the environmental management and nuclear human resource development for the new research reactor designs. 10 MW thermal power by plate type fuel elements and swimming pool type was assumed as a design base. High safety, high cost performance, high reactor operation rate, high technology irradiation are targets of this conceptual design.

Oral presentation

Preparation of national standard human tooth enamel; Comparison of dosimetric signal formation efficiency

Todaka, Azumi*; Toyoda, Shin*; Tachi, Momoko*; Shimazaki, Tatsuya*; Oka, Toshitaka; Yamaguchi, Ichiro*; Inoue, Kazuhiko*; Yasuda, Hiroshi*; Hirota, Seiko*; Tani, Atsushi*; et al.

no journal, , 

To estimate the external exposure dose using electron spin resonance technique, we use a "standard sample" which were prepared at each laboratory with each preparation protocol. It is necessary to unite the preparation protocol for the "real" standard sample. In the point of view of the enamel extraction method, no difference was observed for five dose responses between the absorbed dose and the CO$$_2$$ radical intensity.

11 (Records 1-11 displayed on this page)
  • 1