Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Tamura, Fumihiko; Yamamoto, Masanobu; Yoshii, Masahito*; Omori, Chihiro*; Sugiyama, Yasuyuki*; Okita, Hidefumi; Seiya, Kiyomi*; Nomura, Masahiro; Shimada, Taihei; Hasegawa, Katsushi*; et al.
Proceedings of 68th ICFA Advanced Beam Dynamics Workshop on High Intensity and High Brightness Hadron Beams (HB2023) (Internet), p.305 - 311, 2024/03
The application of MA cores to the accelerating rf cavities in high intensity proton synchrotrons was pioneered for the J-PARC synchrotrons. The MA cavities can generate high accelerating voltages. The wideband frequency response of the MA cavity enables the frequency sweep without the tuning loop. The dual harmonic operation is indispensable for the longitudinal bunch shaping to alleviate the space charge effects in the RCS. These advantages of the MA cavity are also disadvantages when looking at them from a different perspective. Since the wake voltage consists of several harmonics, the beam loading compensation must be multiharmonic. The operation of tubes in the final stage amplifier is not trivial when accelerating very high intensity beams; the output current is high and the anode voltage is also multiharmonic. We summarize our effort against these issues in the operation of the RCS and MR for more than 10 years.
Okita, Hidefumi; Tamura, Fumihiko; Yamamoto, Masanobu; Nomura, Masahiro; Shimada, Taihei; Saha, P. K.; Yoshii, Masahito*; Omori, Chihiro*; Sugiyama, Yasuyuki*; Hasegawa, Katsushi*; et al.
Journal of Physics; Conference Series, 2687(7), p.072005_1 - 072005_7, 2024/01
Longitudinal phase space tomography is an effective measurement tool for acquiring the longitudinal phase space distribution. For the J-PARC synchrotrons, tomography, which can take into account the beam dynamics such as longitudinal space charge effect and nonlinearity, is desired, as the beam power increases. In this study, for the J-PARC synchrotron, the CERN's tomography, which employs the hybrid algorithm that can consider the beam dynamics for reconstruction, is introduced and benchmarked. The benchmark results show that the CERN's tomography has the ability to measure the longitudinal phase space distribution accurately, in the high-power beam operation at the J-PARC synchrotrons.
Tamura, Fumihiko; Okita, Hidefumi; Hotchi, Hideaki*; Saha, P. K.; Meigo, Shinichiro; Yoshii, Masahito*; Omori, Chihiro*; Yamamoto, Masanobu; Seiya, Kiyomi*; Sugiyama, Yasuyuki*; et al.
Proceedings of 20th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.64 - 68, 2023/11
The J-PARC 3GeV synchrotron (RCS) provides high intensity proton beams to the Materials and Life Science Experimental Facility (MLF) and the Main Ring (MR). The harmonic number (h) of the RCS is 2 and the RCS normally accelerates two bunches. For some experiments at the MLF, a single bunch is preferred. In this case, one of the rf bucket is filled with protons and the other is empty. Therefore the beam intensity is halved. If the RCS can accelerate with h=1, the intensity per bunch can be doubled, enabling to provide single bunch beams to the MLF with the maximum intensity. This possibly increases the MR beam power by injecting high intensity single bunches eight times. In this presentation, we report mainly on the consideration of h=1 acceleration in the RCS by longitudinal simulations.
Nagayama, Shota; Harada, Hiroyuki; Shimogawa, Tetsushi*; Sato, Atsushi*; Yamada, Ippei; Chimura, Motoki; Kojima, Kunihiro; Yamamoto, Kazami; Kinsho, Michikazu
Proceedings of 20th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.526 - 530, 2023/11
We have been developing "Non-destructive electrostatic septum" for a slow extraction. This septum has multiple electrodes placed around the region without the beam hitting and separate the beam by its electric field. To evaluate its electric field, we have built a prototype septum and a test machine, which consists of an electron gun and monitors. This test machine can measure the electric field indirectly by using a narrow electron beam. The experiment results of prototype septum is good agreement with the calculation one. However, this electric field distribution is not enough to separate the beam. A step function-like electric field distribution is ideal for the beam separation with minimal negative effect on the beam. We have studied to improve the electrode configuration to match the beam shape. In this paper, we present the result of the electric field measurements and the septum improvement. Additionally, we describe the future plan of this development.
Ishibashi, Atsushi; Masui, Kenji; Goto, Yuichi; Yamamoto, Masahiko; Taguchi, Shigeo; Ishikawa, Satoshi*; Ishikawa, Tomoya*
Nihon Hozen Gakkai Dai-19-Kai Gakujutsu Koenkai Yoshishu, p.18 - 21, 2023/08
An inner-box typed hot cell for analysis of highly radioactive samples has been operated for about 40 years in Tokai Reprocessing Plant since its installation in 1980. During the operation of analytical hot cell, improvement and upgrades including auxiliary equipment have been performed, in addition to keep the equipment in proper condition through periodic inspections and maintenance. This paper describes about these efforts for analytical hot cell and its results.
Yamamoto, Masanobu; Nomura, Masahiro; Okita, Hidefumi; Shimada, Taihei; Tamura, Fumihiko; Hara, Keigo*; Hasegawa, Katsushi*; Omori, Chihiro*; Sugiyama, Yasuyuki*; Yoshii, Masahito*
Progress of Theoretical and Experimental Physics (Internet), 2023(7), p.073G01_1 - 073G01_16, 2023/07
Times Cited Count:0 Percentile:0.01(Physics, Multidisciplinary)The Japan Proton Accelerator Research Complex (J-PARC) Rapid Cycling Synchrotron (RCS) employs Magnetic Alloy (MA) loaded cavities. We realize multi-harmonic rf driving and beam loading compensation owing to the broadband characteristics of the MA. The currently installed cavity is the conventional type one which is designed to be driven by tube amplifiers in a push-pull operation. The push-pull operation has some advantages, i.e., suppressing a higher harmonic distortion without the beam acceleration and shortening the cavity length. However, a disadvantage arises at the high intensity beam acceleration where the multi-harmonic rf driving causes a severe imbalance of the anode voltage swing and restricts the tube operation. Although we have achieved an acceleration for the design beam power of 1 MW, the imbalance becomes an issue to further increase the beam power. We have developed a single-ended MA cavity to avoid such difficulty. The cavity has no tube imbalance intrinsically and it is found that the power consumption to drive the cavity can be reduced compared with the conventional one.
Okudaira, Takuya*; Tani, Yuika*; Endo, Shunsuke; Doskow, J.*; Fujioka, Hiroyuki*; Hirota, Katsuya*; Kameda, Kento*; Kimura, Atsushi; Kitaguchi, Masaaki*; Luxnat, M.*; et al.
Physical Review C, 107(5), p.054602_1 - 054602_7, 2023/05
Times Cited Count:2 Percentile:68.16(Physics, Nuclear)no abstracts in English
Okita, Hidefumi; Tamura, Fumihiko; Yamamoto, Masanobu; Nomura, Masahiro; Shimada, Taihei; Yoshii, Masahito*; Omori, Chihiro*; Sugiyama, Yasuyuki*; Hasegawa, Katsushi*; Hara, Keigo*; et al.
Journal of Physics; Conference Series, 2420, p.012092_1 - 012092_6, 2023/01
A power upgrade of existing 8 kW solid-state driver amplifier is required for the acceleration of high intensity proton beams on the J-PARC 3 GeV rapid cycling synchrotron. The development of a 25 kW amplifier with gallium nitride (GaN) HEMTs, based on 6.4 kW modules is on going. The combiner is a key component to achieve such a high output power over the wide bandwidth required for multi-harmonic rf operation. This paper presents preliminary design of the combiner. The circuit simulation setup and results, including the realistic magnetic core characteristics and frequency response of the cable are reported.
Davies, S. J. C.*; Bolea-Alamanac, B.*; Endo, Kaori*; Yamamoto, Yu*; Yamasaki, Shudo*; Malins, A.; Evans, J.*; Sullivan, S.*; Ando, Shuntaro*; Nishida, Atsushi*; et al.
Journal of Transport & Health, 28, p.101564_1 - 101564_11, 2023/01
Okita, Hidefumi; Tamura, Fumihiko; Yamamoto, Masanobu; Nomura, Masahiro; Shimada, Taihei; Yoshii, Masahito*; Omori, Chihiro*; Hara, Keigo*; Hasegawa, Katsushi*; Sugiyama, Yasuyuki*
Proceedings of 19th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.262 - 266, 2023/01
no abstracts in English
Nomura, Masahiro; Okita, Hidefumi; Shimada, Taihei; Tamura, Fumihiko; Yamamoto, Masanobu; Sugiyama, Yasuyuki*; Hasegawa, Katsushi*; Hara, Keigo*; Omori, Chihiro*; Yoshii, Masahito*
Proceedings of 19th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.215 - 217, 2023/01
no abstracts in English
Endo, Shunsuke; Okudaira, Takuya*; Abe, Ryota*; Fujioka, Hiroyuki*; Hirota, Katsuya*; Kimura, Atsushi; Kitaguchi, Masaaki*; Oku, Takayuki; Sakai, Kenji; Shima, Tatsushi*; et al.
Physical Review C, 106(6), p.064601_1 - 064601_7, 2022/12
Times Cited Count:3 Percentile:52.69(Physics, Nuclear)no abstracts in English
Kyono, Atsushi*; Yamamoto, Genichiro*; Yoneda, Yasuhiro; Okada, Satoru*
Isotope News, (783), p.23 - 27, 2022/10
Mineral traps are attracting attention as an underground storage method for carbon dioxide. Carbon dioxide laden groundwater reacts with basalt to form magnesite. The formed magnesium carbonate phase varies in many ways, but we tried to clarify the structure because all of them pass through amorphous magnesium carbonate. Pair distribution function using high-energy X-ray diffraction revealed that amorphous magnesium carbonate has a structure similar to that of hydromagnesite. It can be said that it is a safe sequestration method as a carbon dioxide storage technology.
Okita, Hidefumi; Tamura, Fumihiko; Yamamoto, Masanobu; Nomura, Masahiro; Shimada, Taihei; Yoshii, Masahito*; Omori, Chihiro*; Hara, Keigo*; Hasegawa, Katsushi*; Sugiyama, Yasuyuki*
Nuclear Instruments and Methods in Physics Research A, 1041, p.167361_1 - 167361_7, 2022/10
Times Cited Count:1 Percentile:33.4(Instruments & Instrumentation)Wideband RF cavities are employed in the Rapid Cycling Synchrotron of the Japan Proton Accelerator Research Complex. RF gap voltage generated during the high power beam acceleration includes the wake voltage and distortion derived from the tube amplifier. The signal from RF gap voltage monitors, which measure the RF gap voltage during the acceleration, includes these effects. We developed the longitudinal beam tracking simulation using the measurement of the RF gap voltage monitors. To apply the measurement of the RF gap voltage monitors to the simulation, the theoretical frequency response models of the voltage divider and the coaxial cable, which are the primary components of the cavity gap voltage monitor, are developed. By taking the frequency response into account, the tracking simulation well reproduces the measured bunch shape at 1 MW.
Yamamoto, Kazami; Kinsho, Michikazu; Hayashi, Naoki; Saha, P. K.; Tamura, Fumihiko; Yamamoto, Masanobu; Tani, Norio; Takayanagi, Tomohiro; Kamiya, Junichiro; Shobuda, Yoshihiro; et al.
Journal of Nuclear Science and Technology, 59(9), p.1174 - 1205, 2022/09
Times Cited Count:5 Percentile:84.97(Nuclear Science & Technology)In the Japan Proton Accelerator Research Complex, the purpose of the 3 GeV rapid cycling synchrotron (RCS) is to accelerate a 1 MW, high-intensity proton beam. To achieve beam operation at a repetition rate of 25 Hz at high intensities, the RCS was elaborately designed. After starting the RCS operation, we carefully verified the validity of its design and made certain improvements to establish a reliable operation at higher power as possible. Consequently, we demonstrated beam operation at a high power, namely, 1 MW. We then summarized the design, actual performance, and improvements of the RCS to achieve a 1 MW beam.
Ishibashi, Atsushi; Saegusa, Yu; Aoya, Juri; Yamamoto, Masahiko; Taguchi, Shigeo; Kuno, Takehiko
Nihon Hozen Gakkai Dai-18-Kai Gakujutsu Koenkai Yoshishu, p.241 - 244, 2022/07
no abstracts in English
Ohshima, Hiroyuki; Morishita, Masaki*; Aizawa, Kosuke; Ando, Masanori; Ashida, Takashi; Chikazawa, Yoshitaka; Doda, Norihiro; Enuma, Yasuhiro; Ezure, Toshiki; Fukano, Yoshitaka; et al.
Sodium-cooled Fast Reactors; JSME Series in Thermal and Nuclear Power Generation, Vol.3, 631 Pages, 2022/07
This book is a collection of the past experience of design, construction, and operation of two reactors, the latest knowledge and technology for SFR designs, and the future prospects of SFR development in Japan. It is intended to provide the perspective and the relevant knowledge to enable readers to become more familiar with SFR technology.
Kato, Atsushi; Yamamoto, Tomohiko; Ando, Masato; Chikazawa, Yoshitaka; Murakami, Hisatomo*; Oyama, Kazuhiro*; Kaneko, Fumiaki*; Higurashi, Koichi*; Chanteclair, F.*; Chenaud, M.-S.*; et al.
EPJ Nuclear Sciences & Technologies (Internet), 8, p.11_1 - 11_10, 2022/06
This paper provides an overview of plant system studies to establish a common technical view for Sodium-cooled Fast Reactor concept between France and Japan based on ASTRID600 and the new concept with downsized output called ASTRID150. One of important issues on a reactor structure design is to enhance seismic resistance to be tolerable against strong earthquake such that postulated in Japan. A concept of High Frequency Design is shared, and the design options related to HFD have been examined and design recommendations are established. In addition, this paper include results of studies for a steam generator, a decay heat removal system, a fuel handling system and a containment vessel.
Yamamoto, Masanobu; Nomura, Masahiro; Okita, Hidefumi; Shimada, Taihei; Tamura, Fumihiko; Hara, Keigo*; Hasegawa, Katsushi*; Omori, Chihiro*; Sugiyama, Yasuyuki*; Yoshii, Masahito*
Proceedings of 13th International Particle Accelerator Conference (IPAC 22) (Internet), p.1336 - 1338, 2022/06
In order to accelerate a high intensity beam in the RCS, a large amplitude of the rf current is provided by a tube amplifier to compensate a heavy beam loading. Tetrode vacuum tubes are used in the RCS, and the control grid voltage enters into a positive region to feed such a large rf current. The positive grid biasing affects the waveform of the control grid voltage; it is deformed due to the induced control grid current under the condition of the multi-harmonic rf driving. Furthermore, the DC bias voltage drop on the control grid is observed because of the exceeding the capability for the control grid power supply. We describe the influence of the positive grid biasing in the RCS.
Koga, Jun*; Takada, Shusuke*; Endo, Shunsuke; Fujioka, Hiroyuki*; Hirota, Katsuya*; Ishizaki, Kohei*; Kimura, Atsushi; Kitaguchi, Masaaki*; Niinomi, Yudai*; Okudaira, Takuya*; et al.
Physical Review C, 105(5), p.054615_1 - 054615_5, 2022/05
Times Cited Count:4 Percentile:66.85(Physics, Nuclear)no abstracts in English