Refine your search:     
Report No.
 - 
Search Results: Records 1-3 displayed on this page of 3
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Development of ultrasonic heat transfer tube thickness measurement apparatus (Contract research)

Oba, Toshihiro; Suetsugu, Hidehiko*; Yano, Masaya*; Kato, Chiaki; Yanagihara, Takao

JAERI-Tech 2002-082, 47 Pages, 2003/01

JAERI-Tech-2002-082.pdf:1.87MB

The demonstration test for evaluating reliability of the acid recovery evaporator at Rokkasho Reprocessing Plant has been carried out at JAERI. For the nondestructive measurement of the thickness of heat transfer tubes of the acid recovery evaporator in corrosion test, we have developed thickness measurement apparatus for heat transfer tubes by ultrasonic immersion method with high resolution. The ultrasonic prove in a heat transfer tube can be moved vertically and radially. The results obtained by this apparatus coincident well with those obtained by a destructive method using an optical microscope.

JAEA Reports

Inspection of heat transfer tubes after mock-up tests of minituarized apparatus for the acid recovery evaporator (Contract research)

Hamada, Shozo; Fukaya, Kiyoshi*; Kato, Chiaki; Yanagihara, Takao; Doi, Masamitsu*; Kiuchi, Kiyoshi

JAERI-Tech 2001-063, 49 Pages, 2001/10

JAERI-Tech-2001-063.pdf:13.39MB

The demonstration test for the acid recovery evaporator and the dissolver used in the major equipment of Rokkasho Reprocessing Plant (RRP), has been carried out. The mock-up miniature equipment has been employed to it. This test had been performed from April in 1998. The total time of demonstration test using the mock-up equipment is about two and half years, which corresponds to about 20,000 hours. After that, four of the seven heat transfer tubes used in the evaporator were drawn out and the corrosion level and the mechanical properties were evaluated for one of them. As a result, intergranular corrosion was recognized in the inner surface of the heat transfer tube and the corrosion depth at the grain boundary was statistically shown to be about one grain from the inner surface. Further, no change in mechanical properties was observed and growth of intergranular cracks in the inner surface of the specimen was found after flattering test.

JAEA Reports

Manufacture of ultrasonic thickness measurement apparatus

Oba, Toshihiro; Yanagihara, Takao; Kato, Chiaki; Hamada, Shozo

JAERI-Tech 2001-059, 36 Pages, 2001/09

JAERI-Tech-2001-059.pdf:7.8MB

The demonstration test for evaluating reliability of the acid recovery evaporator at Rokkasho Reprocessing Plant has been carried out at JAERI. For the nondestructive mesurement of the thickness of heat transfer tubes in the acid recovery evaporator and short tubes used in corrosion test, we have developed ultra sonic thickness measuring apparatus using immersion method with high resolution. This apparatus can measure and record tube thickness automatically with a personal computer. The results obtained by this apparatus are coincident with the results obtained by a destructive method using an optical microscope.

3 (Records 1-3 displayed on this page)