Ito, Chikara; Maeda, Shigetaka; Inoue, Toshihiko; Tomita, Hideki*; Iguchi, Tetsuo*
Radiation Protection, 40(6), p.491 - 495, 2020/11
A highly accurate and precise technique for measurement of the  Nb(n,n')
Nb(n,n') Nb reaction rate was established for the material surveillance tests, etc. in fast reactors. The self-absorption effect on the measurement of the characteristic X-rays emitted by
Nb reaction rate was established for the material surveillance tests, etc. in fast reactors. The self-absorption effect on the measurement of the characteristic X-rays emitted by  Nb was decreased by the solution and evaporation to dryness of niobium dosimeter. A highly precise count of the number of
Nb was decreased by the solution and evaporation to dryness of niobium dosimeter. A highly precise count of the number of  Nb atoms was obtained by measuring the niobium solution concentration using inductively coupled plasma mass spectrometry. X-rays of
Nb atoms was obtained by measuring the niobium solution concentration using inductively coupled plasma mass spectrometry. X-rays of  Nb were measured accurately by means of comparing the X-ray intensity of irradiated niobium solution with that of the solution in which stable
Nb were measured accurately by means of comparing the X-ray intensity of irradiated niobium solution with that of the solution in which stable  Nb was added. The difference between both intensities indicates the effect of
Nb was added. The difference between both intensities indicates the effect of  Ta, which is generated from an impurity tantalum, and the intensity of X-rays from
Ta, which is generated from an impurity tantalum, and the intensity of X-rays from  Nb was evaluated. Measurement error of the
Nb was evaluated. Measurement error of the  Nb(n,n')
Nb(n,n') Nb reaction rate was reduced to be less than 4%, which was equivalent to the other reaction rate errors of dosimeters used for Joyo dosimetry. In addition, an advanced technique using Resonance Ionization Mass Spectrometry was proposed for the precise measurement of
Nb reaction rate was reduced to be less than 4%, which was equivalent to the other reaction rate errors of dosimeters used for Joyo dosimetry. In addition, an advanced technique using Resonance Ionization Mass Spectrometry was proposed for the precise measurement of  Nb yield, and
Nb yield, and  Nb will be resonance-ionized selectively by discriminating the hyperfine splitting of the atomic energy levels between
Nb will be resonance-ionized selectively by discriminating the hyperfine splitting of the atomic energy levels between  Nb and
Nb and  Nb at high resolution.