佐々木 幸太*; 遊佐 訓孝*; 若井 隆純; 橋爪 秀利*
Electromagnetic Nondestructive Evaluation (XVIII), p.244 - 251, 2015/06
被引用回数:0 パーセンタイル:0.00(Mechanics)This study reports evaluations of applicability of a microwave nondestructive testing method for a flaw inside heat exchanger tubes in JSFR, which is a straight long-range tube whose diameter is 11.0 mm. Design of microwave probe profile on the basis of numerical simulations on transmission characteristics at the probe are carried out and the plate-structure microwave probe which enables to largely introduce microwaves into a pipe is confirmed. Experimental evaluations using straight brass pipe whose diameter and length are 11.0 mm and 12.0 m, respectively, reveal that good agreement between predicted location of a flaw and true locations.