Refine your search:     
Report No.
 - 
Search Results: Records 1-5 displayed on this page of 5
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Neutron resonance imaging of a Au-In-Cd alloy for the JSNS

Oi, Motoki; Teshigawara, Makoto; Kai, Tetsuya; Harada, Masahide; Maekawa, Fujio; Futakawa, Masatoshi; Hashimoto, Eiko*; Segawa, Mariko; Kureta, Masatoshi; Tremsin, A.*; et al.

Physics Procedia, 43, p.337 - 342, 2013/04

 Times Cited Count:7 Percentile:92.02

The Japan Spallation Neutron Source (JSNS) at the Japan Proton Accelerator Research Complex (J-PARC) had been developed as a 1-MW spallation neutron source. A Au-In-Cd alloy has been proposed as a new decoupler material. Recently, we successfully produced the ternary Au-In-Cd alloy. The alloy composition is 74.9 at% Au, 0.5 at% In, and 24.6 at% Cd. We used the pulsed neutron imaging techniques to measure the elements in the Au-In-Cd alloy. Both a time gated camera system and a multi-channel plate (MCP) detector were used as detectors. Measurement was performed at BL10 in the JSNS. A Au-In-Cd specimen, In foil and two Au foils are used as a sample. As a results, we could obtain distribution of Au, In and Cd in the Au-In-Cd specimens distinctly.

Journal Articles

Quantitative measurements of element distributions using the neutron-transmission resonance-absorption method

Harada, Masahide; Parker, J. D.*; Sawano, Tatsuya*; Kubo, Hidetoshi*; Tanimori, Toru*; Shinohara, Takenao; Maekawa, Fujio; Sakai, Kenji

Physics Procedia, 43, p.314 - 322, 2013/00

 Times Cited Count:1 Percentile:54.2

The purposes of this study are to perform Neutron Resonance Absorption NRA test experiments using the Micro Pixel Chamber, and to confirm its quantitativity. The detector was located at 14.5 m from the moderator in the experimental room of NOBORU. The samples, consisting of thin Tantalum (Ta) foils, with thicknesses of 5, 10, 20 and 100 $$mu$$m, were placed individually at 15 cm upstream from the detector. In the experiment, the transmission spectra with the Ta samples and no sample were obtained. Background components were not so small in these measurements. From the neutron transport simulation, it was surmised that the origin of this background was due to scattering of neutrons in the experimental room. Therefore, the assumed background components were subtracted from the measurement data. Finally, it was found that the difference between the measurement data and the nuclear data was within about 7%.

Journal Articles

Investigation of the brightness enhancement using brightness enhancement films on a scintillator

Iikura, Hiroshi; Tsutsui, Noriaki*; Saito, Yasushi*; Nojima, Takehiro; Yasuda, Ryo; Sakai, Takuro; Matsubayashi, Masahito

Physics Procedia, 43, p.161 - 168, 2013/00

 Times Cited Count:4 Percentile:84.31

Journal Articles

Development of an imaging system for the observation of water behavior in a channel in PEFC

Nojima, Takehiro; Yasuda, Ryo; Takenaka, Nobuyuki*; Katagiri, Masaki*; Iikura, Hiroshi; Sakai, Takuro; Matsubayashi, Masahito

Physics Procedia, 43, p.282 - 287, 2013/00

 Times Cited Count:2 Percentile:70.06

We developed a new imaging system for observing the water distribution in Polymer Electrolyte Fuel Cell (PEFC) under operation. This imaging system realizes both low noise and high sensitivity imaging and it enables to obtain an image in relatively short exposure time. This imaging system consists of EM-CCD (Electron Multiplication-Charged Coupled Device) camera, a LiF/ZnS scintillator screen and slit system. The EM-CCD camera has wide dynamic range and high sensitivity. The brightness of the scintillator screen is about three times higher than that of conventional type. The slit system was used for reducing the white dot noise caused by primary and/or secondary prompt $$gamma$$ rays. A characteristic test of this imaging system using JARI (Japan Automobile Research Institute)-standard cell was carried out at TNRF. In the results of the test, qualitative and quantitative observation of water behavior in the channel of PEFC was archived by the new imaging system.

Journal Articles

Development of a high-performance optical system and fluorescent converters for high-resolution neutron imaging

Sakai, Takuro; Yasuda, Ryo; Iikura, Hiroshi; Nojima, Takehiro; Matsubayashi, Masahito

Physics Procedia, 43, p.223 - 230, 2013/00

 Times Cited Count:0 Percentile:0

5 (Records 1-5 displayed on this page)
  • 1