Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Oi, Motoki; Teshigawara, Makoto; Kai, Tetsuya; Harada, Masahide; Maekawa, Fujio; Futakawa, Masatoshi; Hashimoto, Eiko*; Segawa, Mariko; Kureta, Masatoshi; Tremsin, A.*; et al.
Physics Procedia, 43, p.337 - 342, 2013/04
Times Cited Count:13 Percentile:94.97(Physics, Applied)The Japan Spallation Neutron Source (JSNS) at the Japan Proton Accelerator Research Complex (J-PARC) had been developed as a 1-MW spallation neutron source. A Au-In-Cd alloy has been proposed as a new decoupler material. Recently, we successfully produced the ternary Au-In-Cd alloy. The alloy composition is 74.9 at% Au, 0.5 at% In, and 24.6 at% Cd. We used the pulsed neutron imaging techniques to measure the elements in the Au-In-Cd alloy. Both a time gated camera system and a multi-channel plate (MCP) detector were used as detectors. Measurement was performed at BL10 in the JSNS. A Au-In-Cd specimen, In foil and two Au foils are used as a sample. As a results, we could obtain distribution of Au, In and Cd in the Au-In-Cd specimens distinctly.
Sakai, Takuro; Yasuda, Ryo; Iikura, Hiroshi; Nojima, Takehiro; Matsubayashi, Masahito
Physics Procedia, 43, p.223 - 230, 2013/00
Times Cited Count:0 Percentile:0.00(Physics, Applied)Kai, Tetsuya; Maekawa, Fujio; Oshita, Hidetoshi*; Sato, Hirotaka; Shinohara, Takenao; Oi, Motoki; Harada, Masahide; Uno, Shoji*; Otomo, Toshiya*; Kamiyama, Takashi*; et al.
Physics Procedia, 43, p.111 - 120, 2013/00
Times Cited Count:20 Percentile:98.14(Physics, Applied)A neutron imaging instrument is in construction at the pulsed neutron source of J-PARC. Some demonstration experiments in NOBORU/J-PARC have carried. To explore widespread applications of the newly built instruments it is indispensable to indicate the range of coverage of this technique. In the presentation, the authors describe the results of some of demonstration measurements, and then compare all elements with the values obtained by multiplying peak cross section and peak widths of neutron resonances in evaluated nuclear data libraries. This value is expected to be a good measure to exhibit visibility of each element in this technique.
Harada, Masahide; Parker, J. D.*; Sawano, Tatsuya*; Kubo, Hidetoshi*; Tanimori, Toru*; Shinohara, Takenao; Maekawa, Fujio; Sakai, Kenji
Physics Procedia, 43, p.314 - 322, 2013/00
Times Cited Count:1 Percentile:51.74(Physics, Applied)The purposes of this study are to perform Neutron Resonance Absorption NRA test experiments using the Micro Pixel Chamber, and to confirm its quantitativity. The detector was located at 14.5 m from the moderator in the experimental room of NOBORU. The samples, consisting of thin Tantalum (Ta) foils, with thicknesses of 5, 10, 20 and 100 m, were placed individually at 15 cm upstream from the detector. In the experiment, the transmission spectra with the Ta samples and no sample were obtained. Background components were not so small in these measurements. From the neutron transport simulation, it was surmised that the origin of this background was due to scattering of neutrons in the experimental room. Therefore, the assumed background components were subtracted from the measurement data. Finally, it was found that the difference between the measurement data and the nuclear data was within about 7%.
Iikura, Hiroshi; Tsutsui, Noriaki*; Saito, Yasushi*; Nojima, Takehiro; Yasuda, Ryo; Sakai, Takuro; Matsubayashi, Masahito
Physics Procedia, 43, p.161 - 168, 2013/00
Times Cited Count:5 Percentile:86.07(Physics, Applied)Nojima, Takehiro; Yasuda, Ryo; Takenaka, Nobuyuki*; Katagiri, Masaki*; Iikura, Hiroshi; Sakai, Takuro; Matsubayashi, Masahito
Physics Procedia, 43, p.282 - 287, 2013/00
Times Cited Count:2 Percentile:67.71(Physics, Applied)We developed a new imaging system for observing the water distribution in Polymer Electrolyte Fuel Cell (PEFC) under operation. This imaging system realizes both low noise and high sensitivity imaging and it enables to obtain an image in relatively short exposure time. This imaging system consists of EM-CCD (Electron Multiplication-Charged Coupled Device) camera, a LiF/ZnS scintillator screen and slit system. The EM-CCD camera has wide dynamic range and high sensitivity. The brightness of the scintillator screen is about three times higher than that of conventional type. The slit system was used for reducing the white dot noise caused by primary and/or secondary prompt rays. A characteristic test of this imaging system using JARI (Japan Automobile Research Institute)-standard cell was carried out at TNRF. In the results of the test, qualitative and quantitative observation of water behavior in the channel of PEFC was archived by the new imaging system.