Sanada, Yukihisa; Ishii, Masato*; Hasegawa, Ichiro; Kanazawa, Nobuyuki; Chikazawa, Tatsuya*; Momose, Takumaro
NEA/CSNI/R(2010)4 (Internet), p.351 - 370, 2010/11
A criticality accident alarm system (CAAS) was installed in the 1980s as part of criticality safety management at the Tokai Reprocessing Plant (TRP) to reduce the chance of workers being exposed to radiation in the rare case of a criticality accident. From a compliance point of view processing at TRP cannot take place without the criticality monitoring provided by the CAAS. This paper gives an overview of the process of the CAAS being replaced as part of aging management.
Nakano, Takafumi; Inano, Masatoshi; Aoshima, Atsushi
no journal, ,
no abstracts in English