Ogawa, Hiroaki; Ishikawa, Norito
2023-Nendo Daigaku Kenkyu Josei Gijutsu Kenkyu Hokokusho, p.123 - 134, 2024/03
Evaluation of corrosion and hydrogen embrittlement is important in the quality control of stainless steel and the development of next steel materials assuming a high-pressure hydrogen environment. Typically, a secondary ion mass spectrometer (SIMS) is used to analyze hydrogen in steel materials. The hydrogen concentration of conventional standard substance for hydrogen analysis is as small as 1wt-ppm, which has been a problem in hydrogen analysis. We use a hydrogen-implant method to create a locally higher hydrogen concentration than that of the conventional. Hydrogen concentration analysis has been evaluated using the nuclear reaction analysis (NRA) method at a tandem accelerator. We have succeeded in creating a sample with a higher hydrogen concentration of about 1,900 wt-ppm than that of the conventional in locally.