Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Matsuda, Makoto; Asozu, Takuhiro; Sataka, Masao; Hanashima, Susumu; Nakamura, Masahiko; Kabumoto, Hiroshi; Kutsukake, Kenichi
Dai-23-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.65 - 68, 2011/07
no abstracts in English
Ishizaki, Nobuhiro; Ishii, Tetsuro; Abe, Shinichi; Hanashima, Susumu; Osa, Akihiko; Tayama, Hidekazu; Matsuda, Makoto; Nakanoya, Takamitsu; Kabumoto, Hiroshi; Nakamura, Masahiko; et al.
Dai-23-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.13 - 16, 2010/11
no abstracts in English
Kokubu, Yoko; Nishizawa, Akimitsu*; Suzuki, Mototaka*; Owaki, Yoshio*; Nishio, Tomohiro*; Matsubara, Akihiro; Ishimaru, Tsuneari
Dai-23-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.45 - 48, 2010/11
no abstracts in English
Tanaka, Takayuki; Kabuto, Shoji; Kinoshita, Naoki; Suzuki, Takashi; Kuwabara, Jun; Seki, Takeo
Dai-23-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.113 - 116, 2010/11
An accelerator mass spectrometry at Aomori Research and Development Center, JAEA (JAEA-AMS-MUTSU) was established in 1997 and the routine operation of C and I measurement was started from 1999 and 2003, respectively. This AMS has adopted the open door policy for the general users from the fiscal year of 2006 and various researches have been in progress by many users. In this presentation, we introduce the status of JAEA-AMS-MUTSU in the fiscal year of 2009. The C and I were measured by 480 and 677 samples in the fiscal year of 2009, respectively. The total number of measurements has decreased by 716 samples from that of the fiscal year of 2008. The reasons for this decrease were that we had stopped the operation of AMS for about one and half months because the operation system of AMS was upgraded, and that we could not measure the C for several months because the amplifier of detector had broken. We had resolved this trouble and our AMS can measure smoothly both C and I.
Chiba, Atsuya; Uno, Sadanori; Yamada, Keisuke; Yokoyama, Akihito; Agematsu, Takashi; Yokota, Wataru; Kitano, Toshihiko*; Takayama, Terumitsu*; Kanai, Shinji*; Orimo, Takao*; et al.
Dai-23-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.119 - 122, 2010/11
Operation times of each accelerator are keeping the same level as in recent 10 years, Tandem accelerator, Single-ended and Ion implanter amounted to about 2,000, 2,500 and 1,900 hours, respectively. In the last fiscal year, we succeeded in maintaining the terminal voltage of the tandem accelerator to high stability for long periods by exchanging the material of a corona-probe needle to the tungsten (NPS Co.). In the ion-implanter, the oven control system equipped with the Freeman ion source was renewed. There was no trouble to affect on the machine-time in the last fiscal year, so the all planned experiments were carried out.
Matsubara, Akihiro; Nishizawa, Akimitsu*; Suzuki, Mototaka*; Owaki, Yoshio*; Nishio, Tomohiro*; Kokubu, Yoko; Ishimaru, Tsuneari
Dai-23-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.53 - 56, 2010/11
no abstracts in English
Otokawa, Yoshinori; Osa, Akihiko; Sato, Tetsuya; Matsuda, Makoto
Dai-23-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.135 - 138, 2010/07
no abstracts in English
Yokoyama, Akihito; Ishii, Yasuyuki; Chiba, Atsuya; Uno, Sadanori; Agematsu, Takashi; Takayama, Terumitsu*; Kitano, Toshihiko*
Dai-23-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.147 - 150, 2010/07
no abstracts in English