Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Maeda, Makoto; Komeda, Masao; Ozu, Akira; Kureta, Masatoshi; Toh, Yosuke; Bogucarska, T.*; Crochemore, J. M.*; Varasano, G.*; Pedersen, B.*
EUR-28795-EN (Internet), p.694 - 701, 2017/00
Toh, Yosuke; Ozu, Akira; Tsuchiya, Harufumi; Furutaka, Kazuyoshi; Kitatani, Fumito; Komeda, Masao; Maeda, Makoto; Kureta, Masatoshi; Koizumi, Mitsuo; Seya, Michio; et al.
EUR-28795-EN (Internet), p.684 - 693, 2017/00
Sekine, Megumi; Matsuki, Takuya; Suzuki, Satoshi; Tanigawa, Masafumi; Yasuda, Takeshi; Yamanaka, Atsushi; Tsutagi, Koichi; Nakamura, Hironobu; Tomikawa, Hirofumi; LaFleur, A. M.*; et al.
EUR-28795-EN (Internet), p.788 - 796, 2017/00
The IAEA has proposed in its long-term R&D plan, the development of technology to enable real-time flow measurement of nuclear material as a part of an advanced approach to effective and efficient safeguards for reprocessing facilities. To address this, JAEA has designed and developed a neutron coincidence based nondestructive assay system to monitor Pu directly in solutions which is after purification process and contains very little fission products (FPs). A new detector to enable monitoring of Pu in solutions with numerous FPs is being developed as a joint research program with U.S. DOE at the High Active Liquid Waste (HALW) Storage Facility in Tokai Reprocessing Plant. As the first step, the design information of HALW tank was investigated and samples of HALW was taken and analyzed for Pu concentration and isotope composition, density, content of dominant nuclides emitting ray or neutron, etc. in order to develop a Monte Carlo N-Particle Transport Code (MCNP) of the HALW tank. In addition,
ray source spectra simulated by Particle and Heavy Ion Transport code System (PHITS) was developed by extracting peaks from the analysis data with germanium detector. These outputs are used for the fundamental data in the MCNP model which is then used to evaluate the type of detector, shielding design and measurement positions. In order to evaluate available radiations to measure outside the cell wall, continuous
ray and neutron measurement were carried out and the results were compared to the simulation results. The measurement results showed that there are no FP peaks above 3 MeV. This paper presents an overview of the research plan, characteristics of HALW, development of source term for MCNP, simulation of radiation dose from the HALW tank and radiation measurement results at outside of cell wall.
Henzlova, D.*; Menlove, H. O.*; Tanigawa, Masafumi; Mukai, Yasunobu; Nakamura, Hironobu
EUR-28795-EN (Internet), p.313 - 323, 2017/00
Facing the depletion of He gas supply and the continuing uncertainty of options for future resupply, Los Alamos National Laboratory (LANL) designed and built a
He free full scale thermal neutron coincidence counter based on boron-lined parallel-plate proportional technology. The counter was designed as a direct alternative to High Level Neutron Coincidence counter (HLNC-II). This paper provides a summary of performance evaluation of HLNB under realistic field conditions at Plutonium Conversion Development Facility (PCDF) of Japan Atomic Energy Agency (JAEA). The field test included a range of small to large mass MOX materials that represent realistic process samples and provided key insight on and validation of the feasibility of HLNB as a safeguards instrument in realistic facility environment. In particular, the results of verification measurements demonstrate that HLNB is capable to satisfy ITV expected for HLNC-II-type counter of 2.1% in 300s measurement time.
Koizumi, Mitsuo; Rossi, F.; Rodriguez, D.; Takamine, Jun; Seya, Michio; Bogucarska, T.*; Crochemore, J.-M.*; Varasano, G.*; Abbas, K.*; Pedersen, B.*; et al.
EUR-28795-EN (Internet), p.868 - 872, 2017/00