Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 24

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Development and application of a $$^3$$He neutron spin filter at J-PARC

Okudaira, Takuya; Oku, Takayuki; Ino, Takashi*; Hayashida, Hirotoshi*; Kira, Hiroshi*; Sakai, Kenji; Hiroi, Kosuke; Takahashi, Shingo*; Aizawa, Kazuya; Endo, Hitoshi*; et al.

Nuclear Instruments and Methods in Physics Research A, 977, p.164301_1 - 164301_8, 2020/10

 Times Cited Count:0

Journal Articles

The Role of the research reactor JRR-3 in neutron sciences

Takeda, Masayasu; Matsubayashi, Masahito

Nippon Genshiryoku Gakkai-Shi, 58(6), p.371 - 375, 2016/06

no abstracts in English

Journal Articles

Systematic effects on cross-section data derived from reaction rates at a cold neutron beam

$v{Z}$erovnik, G.*; Becker, B.*; Belgya, T.*; Genreith, C.*; Harada, Hideo; Kopecky, S.*; Radulovi$'c$, V.*; Sano, Tadafumi*; Schillebeeckx, P.*; Trkov, A.*

Nuclear Instruments and Methods in Physics Research A, 799, p.29 - 36, 2015/11

 Times Cited Count:4 Percentile:53.79(Instruments & Instrumentation)

The methodology to derive cross section data from measurements in a cold neutron beam was studied. Mostly, capture cross sections at thermal energy are derived relative to a standard cross section, and proportionality between the standard and the measured cross section is often assumed. Due to this assumption the derived capture cross section at thermal energy can be biased by more than 10%. Evidently the bias depends on how much the energy dependence of the cross section deviates from a direct proportionality with the inverse of the neutron speed. The effect is reduced in case the cross section is not derived at thermal energy but at an energy close to the average energy of the cold neutron beam. Nevertheless, it is demonstrated that the bias can only be avoided in case the energy dependence of the cross section is known and proper correction factors are applied. In some cases the results can also be biased when the attenuation of the neutron beam within the sample is neglected in the analysis. Some of the cross section data reported in the literature suffer from such bias effects.

Journal Articles

Visualization and measurement of the inside mortaring car engine

Kureta, Masatoshi

Hamon, 24(特別号), 2 Pages, 2014/11

The fundamentals and applications on the neutron imaging technique, volume visualization and 3D measurement by the neutron 3D-CT technique and the most advanced imaging technique by using pulsed neutrons were reviewed in this paper. Visualization and measurement of the inside mortaring car engine is one of the industrial applications on the neutron imaging technique. This technique was also applied for visualization and measurement of the multiphase plow applications. The 3D visualization technique has been used for the concrete research etc. The pulsed neutron imaging techniques developed for J-PARC have made possible element-selective imaging and metallographic structure imaging which were impossible by the traditional techniques. Newly providing pulsed neutron imaging facilities for common use is also introduced briefly.

Journal Articles

Multiple prompt $$gamma$$-ray analysis and construction of its beam line

Oshima, Masumi; Toh, Yosuke; Kimura, Atsushi; Ebihara, Mitsuru*; Oura, Yasuji*; Ito, Yasuo*; Sawahata, Hiroyuki*; Matsuo, Motoyuki*

Journal of Radioanalytical and Nuclear Chemistry, 271(2), p.317 - 321, 2007/02

 Times Cited Count:11 Percentile:34.67(Chemistry, Analytical)

By combining neutron activation analysis with multiple $$gamma$$-ray detection, we have proved better sensitivity and resolution for the trace element analysis than the ordinary single $$gamma$$-ray detection method. We now try to apply the multiple $$gamma$$-ray detection method to the prompt $$gamma$$-ray analysis (PGA). We have established a new cold neutron beam line for PGA in Japan Research Reactor, JRR-3M, at Tokai establishment of Japan Atomic Energy Research Institute(JAERI). It consists of a beam shutter, a beam attenuator, a $$gamma$$-ray detector array, a sample changer, and a beam stopper. We construct a high-efficiency $$gamma$$-ray detector array specially designed for this purpose. Its performance has been evaluated with the Monte Carlo simulation code, GEANT 4.5.0.

Journal Articles

Nondestructive elemental analysis using neutron

Matsue, Hideaki; Tanji, Akira; Miyata, Satoru; Yasuda, Ryo; Matsubayashi, Masahito; Nakanishi, Tomoko

Dai-5-Kai Hoshasen Ni Yoru Hihakai Hyoka Shimpojiumu Koen Rombunshu, p.45 - 48, 2005/02

no abstracts in English

Journal Articles

The Recommended k$$_{0}$$-factors for neutron-induced prompt $$gamma$$-ray analysis and the prompt $$gamma$$-ray emission probabilities

Matsue, Hideaki; Yonezawa, Chushiro

Journal of Radioanalytical and Nuclear Chemistry, 262(1), p.49 - 55, 2004/07

 Times Cited Count:9 Percentile:43.92

The recommended k$$_{0}$$ factors for 81 $$gamma$$-lines of 24 elements, which are useful for neutron induced prompt $$gamma$$-ray analysis (PGA) and are not influenced by neutron spectrum difference, were obtained from the k$$_{0}$$ factors measured with the cold and thermal guided neutron beams of JRR-3M by statistical calculation. The prompt $$gamma$$-ray emission probabilities were derived from the recommended k$$_{0}$$-factors using atomic weight, isotopic abundance and thermal neutron cross-section of other nuclear constants consisting the k$$_{0}$$ factors, for which one can obtain accurate data. The derived $$gamma$$-ray emission probabilities for the light elements (H to Ca) well agreed within $$pm$$10% with those of the ENSDF, which reflect recent data, which the agreements for heavy elements (Ti to Pb) were $$pm$$40% with those of the ENSDF, which are still composed of old data.

Journal Articles

Neutron spectrum correction of k$$_{0}$$-factors for k$$_{0}$$-based neutron-induced prompt $$gamma$$-ray analysis

Matsue, Hideaki; Yonezawa, Chushiro

Journal of Radioanalytical and Nuclear Chemistry, 255(1), p.125 - 129, 2003/01

 Times Cited Count:8 Percentile:47.38

no abstracts in English

Journal Articles

Multielement determination of typical diet reference materials by neutron-induced prompt $$gamma$$-ray analysis using k$$_{0}$$ standardization

Matsue, Hideaki; Yonezawa, Chushiro

Journal of Radioanalytical and Nuclear Chemistry, 249(1), p.11 - 14, 2001/06

no abstracts in English

JAEA Reports

None

*

JNC-TN1400 2000-003, 0 Pages, 2000/07

JNC-TN1400-2000-003.pdf:13.33MB

None

Journal Articles

k$$_{0}$$ standardization approach in neutron-induced prompt $$gamma$$-ray analysis at JAERI

Matsue, Hideaki; Yonezawa, Chushiro

Journal of Radioanalytical and Nuclear Chemistry, 245(1), p.189 - 194, 2000/04

 Times Cited Count:21 Percentile:19.91(Chemistry, Analytical)

no abstracts in English

Journal Articles

The 6th Asian Symposium on Research Reactors (ASRR-VI)

Fujiki, Kazuo

Nippon Genshiryoku Gakkai-Shi, 41(9), p.933 - 934, 1999/09

no abstracts in English

JAEA Reports

None

JNC-TN1400 99-016, 171 Pages, 1999/08

JNC-TN1400-99-016.pdf:8.97MB

no abstracts in English

Journal Articles

A Study of the proton storage ring for the neutron science project at JAERI

Kinsho, Michikazu; Noda, Fumiaki*; Kusano, Joichi; Mizumoto, Motoharu

Proc. of 1st Asian Particle Accelerator Conf. (APAC98), p.411 - 413, 1998/11

no abstracts in English

Journal Articles

Decomposition of prompt $$gamma$$-ray spectra including the Doppler-broadened peak for boron determination

Magara, Masaaki; Yonezawa, Chushiro

Nuclear Instruments and Methods in Physics Research A, 411(1), p.130 - 136, 1998/00

 Times Cited Count:24 Percentile:13.22(Instruments & Instrumentation)

no abstracts in English

JAEA Reports

None

PNC-TN1430 97-001, 28 Pages, 1997/01

PNC-TN1430-97-001.pdf:1.3MB

no abstracts in English

Journal Articles

Effect of beam spectrum on quantitativeness of cold neutron computed tomography

*; *; Matsubayashi, Masahito; Mori, Chizuo*

Nippon Genshiryoku Gakkai-Shi, 39(8), p.647 - 656, 1997/00

 Times Cited Count:0 Percentile:100(Nuclear Science & Technology)

no abstracts in English

Journal Articles

Neutron science project at JAERI

Mukaiyama, Takehiko; Oyama, Yukio; Mizumoto, Motoharu; Takizuka, Takakazu; Hino, Ryutaro

Proc. of Topical Meeting on Nuclear Applications of Accelerator Technology, p.398 - 404, 1997/00

no abstracts in English

JAEA Reports

None

; Momose, Takumaro; Shinohara, Kunihiko

PNC-TN8410 96-402, 90 Pages, 1996/12

PNC-TN8410-96-402.pdf:5.39MB

None

JAEA Reports

None

; ; Momose, Takumaro; Shinohara, Kunihiko

PNC-TN8410 96-397, 14 Pages, 1996/12

PNC-TN8410-96-397.pdf:0.62MB

None

24 (Records 1-20 displayed on this page)