Yoshikawa, Ryuji; Imai, Yasutomo*; Kikuchi, Norihiro; Tanaka, Masaaki; Gerschenfeld, A.*
Proceedings of 30th International Conference on Nuclear Engineering (ICONE30) (Internet), 10 Pages, 2023/05
Removal of core decay heat by utilizing natural circulation is expected as a significant measure to enhance the safety of sodium-cooled fast reactors (SFRs). Accurate evaluation of the temperature distribution in the fuel assembly (FA) at the low Re regime in natural circulation operation is demanded. A detailed thermal-hydraulics analysis code named SPIRAL has been developed to clarify thermal-hydraulic phenomena in the FA at various operation conditions. In this study, SPIRAL with the hybrid turbulence model was applied to analyze a large-scale fuel assembly experiment of a 91-pin bundle for two cases at the mixed and the natural convection conditions respectively in low Re regime with heat transfer from outside of the FA. The applicability of the SPIRAL to the thermal-hydraulics evaluation of FA at mixed and natural convection conditions was confirmed by the comparisons of temperatures predicted by SPIRAL with those measured in the experiment.
Takamatsu, Kuniyoshi; Funatani, Shumpei*
Proceedings of 2023 International Congress on Advanced in Nuclear Power Plants (ICAPP 2023) (Internet), 17 Pages, 2023/04
The objectives of this study are as follows: to understand the characteristics, degree of passive safety features for heat removal were compared for RCCSs based on atmospheric radiation and based on atmospheric natural circulation under the same conditions. Therefore, the authors concluded that the proposed RCCS based on atmospheric radiation has the advantage that the temperature of the RPV can be stably maintained against disturbances in the outside air (ambient air). Moreover, methodology to utilize all the heat emitted from the RPV surface for increasing the degree of waste-heat utilization was discussed.
Takamatsu, Kuniyoshi; Matsumoto, Tatsuya*; Liu, W.*; Morita, Koji*
Annals of Nuclear Energy, 162, p.108512_1 - 108512_10, 2021/11
Times Cited Count:1 Percentile:15.09(Nuclear Science & Technology)The objectives of this study are as follows: to understand the characteristics, degree of passive safety features for heat removal were compared for RCCSs based on atmospheric radiation and based on atmospheric natural circulation under the same conditions. Next, simulations on accidental conditions, such as increasing average heat-transfer coefficient via natural convection due to natural disasters, were performed with STAR-CCM+, and methodology to control the amount of heat removal was discussed. As a result, a new RCCS based on atmospheric radiation is recommended because of the excellent degree of passive safety features/conditions, and the amount of heat removal by heat transfer surfaces which can be controlled. Finally, methodology to determine structural thickness of scaled-down heat removal test facilities for reproducing natural convection and radiation was developed, and experimental methods by using pressurized and decompressed chambers was also proposed.
Takamatsu, Kuniyoshi; Matsumoto, Tatsuya*; Liu, W.*; Morita, Koji*
Annals of Nuclear Energy, 151, p.107867_1 - 107867_11, 2021/02
Times Cited Count:2 Percentile:29.53(Nuclear Science & Technology)A new RCCS with passive safety features consists of two continuous closed regions. One is a region surrounding RPV. The other is a cooling region with heat transferred to the ambient air. The new RCCS needs no electrical or mechanical driving devices. We compared the RCCS using atmospheric radiation with that using atmospheric natural circulation in terms of passive safety features and control methods for heat removal. The magnitude relationship for passive safety features is heat conduction radiation natural convection. Therefore, the magnitude for passive safety features of the former RCCS can be higher than that of the latter RCCS. In controlling the heat removal, the former RCCS changes the heat transfer area only. On the other hand, the latter RCCS needs to change the chimney effect. It is necessary to change the air resistance in the duct. Therefore, the former RCCS can control the heat removal more easily than the latter RCCS.
Hamdani, A.; Abe, Satoshi; Ishigaki, Masahiro; Shibamoto, Yasuteru; Yonomoto, Taisuke
Energies (Internet), 13(14), p.3652_1 - 3652_22, 2020/07
Times Cited Count:6 Percentile:21.88(Energy & Fuels)Takamatsu, Kuniyoshi; Matsumoto, Tatsuya*; Liu, W.*; Morita, Koji*
Annals of Nuclear Energy, 133, p.830 - 836, 2019/11
Times Cited Count:2 Percentile:20.94(Nuclear Science & Technology)A RCCS having passive safety features through radiation and natural convection was proposed. The RCCS design consists of two continuous closed regions: an ex-reactor pressure vessel region and a cooling region with a heat-transfer surface to ambient air. The RCCS uses a novel shape to remove efficiently the heat released from the RPV through as much radiation as possible. Employing air as the working fluid and ambient air as the ultimate heat sink, the RCCS design can strongly reduce the possibility of losing the working fluid and the heat sink for decay-heat-removal. Moreover, the authors started experiment research with using a scaled-down heat-removal test facility. Therefore, this study propose a comparative methodology between an actual RCCS and a scaled-down heat-removal test facility.
Takada, Shoji; Ngarayana, I. W.*; Nakatsuru, Yukihiro*; Terada, Atsuhiko; Murakami, Kenta*; Sawa, Kazuhiko*
Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 13 Pages, 2019/05
In the loss of core cooling test using HTTR, a technical issue is to improve prediction accuracy of temperature distribution of components in vessel cooling system (VCS). An establishment of reasonable 2D model was started by using numerical code FLUENT, which was validated using the test data by 1/6 scale model of VCS for HTTR. The pressure vessel (PV) temperature was set around 200C attributed to relatively high ratio of natural convection heat transfer around 20% in total heat removal, which is useful for code to experiment benchmark to improve prediction accuracy. It is necessary to confirm heat transfer flow characteristics around the top of PV which is heated up by natural convection flow which was considered to be affected by separation, re-adhesion and transition flow. The k--SST model was selected for turbulent calculation attributed to predict the effects mentioned above adequately. The numerical results using the k--SST model reproduced the temperature distribution of PV especially the top region which is considered to be affected by separation, re-adhesion and transition flow in contract to that using k- model which does not account the effects.
Onodera, Naoyuki; Idomura, Yasuhiro; Kawamura, Takuma; Uesawa, Shinichiro; Yamashita, Susumu; Yoshida, Hiroyuki
Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 6 Pages, 2019/05
A dry method is one of practical methods for decommissioning the TEPCO's Fukushima Daiichi Nuclear Power Station. Japan Atomic Energy Agency (JAEA) has been evaluating the air cooling performance by using the JUPITER code. However, the JUPITER code requires a large computational cost to capture debris' structures. To accelerate such CFD analyses, we use the CityLBM code, which is based on the lattice Boltzmann method (LBM) and is highly optimized for GPUs. The CityLBM code is validated against free convective heat transfer experiments at JAEA, and the similar accuracy as the JUPITER code is confirmed regarding the prediction capability of heat transfer and the resulting temperature distributions. It is also shown that the elapse time of a CityLBM simulation on GPUs is reduced to 1/6 compared with that of the corresponding JUPITER simulation on CPUs with the same number of GPUs and CPUs. The results show that the LBM is promising for accelerating thermal convective simulations.
Takamatsu, Kuniyoshi; Matsumoto, Tatsuya*; Liu, W.*; Morita, Koji*
Annals of Nuclear Energy, 122, p.201 - 206, 2018/12
Times Cited Count:4 Percentile:37.66(Nuclear Science & Technology)A RCCS having passive safety features through radiation and natural convection was proposed. The RCCS design consists of two continuous closed regions: an ex-reactor pressure vessel region and a cooling region with a heat-transfer surface to ambient air. The RCCS uses a novel shape to remove efficiently the heat released from the RPV through as much radiation as possible. Employing air as the working fluid and ambient air as the ultimate heat sink, the RCCS design can strongly reduce the possibility of losing the working fluid and the heat sink for decay-heat-removal. This study addresses an improvement of heat-removal capability using heat conduction on the RCCS. As a result, a heat flux removed by the RCCS could be doubled; therefore, it is possible to halve the height of the RCCS or increase the thermal reactor power.
Hosomi, Seisuke*; Akashi, Tomoyasu*; Matsumoto, Tatsuya*; Liu, W.*; Morita, Koji*; Takamatsu, Kuniyoshi
Proceedings of 11th Korea-Japan Symposium on Nuclear Thermal Hydraulics and Safety (NTHAS-11) (Internet), 7 Pages, 2018/11
A new RCCS with passive safety features consists of two continuous closed regions. One is a region surrounding RPV. The other is a cooling region with heat transferred to the ambient air. The new RCCS needs no electrical or mechanical driving devices. We started experiment research with using a scaled-down test section. Three experimental cases under different emissivity conditions were performed. We used Monte Carlo method to evaluate the contribution of radiation to the total heat released from the heater. As a result, after the heater wall was painted black, the contribution of radiation to the total heat could be increased to about 60%. A high emissivity of RPV surface is very effective to remove more heat from the reactor. A high emissivity of the cooling part wall is also effective because it not only increases the radiation emitted to the ambient air, but also may increase the temperature difference among the walls and enhance the convection heat transfer in the RCCS.
Uesawa, Shinichiro; Yamashita, Susumu; Shibata, Mitsuhiko; Yoshida, Hiroyuki
Proceedings of 25th International Conference on Nuclear Engineering (ICONE-25) (CD-ROM), 7 Pages, 2017/07
Uesawa, Shinichiro; Koizumi, Yasuo; Shibata, Mitsuhiko; Nagatake, Taku; Yoshida, Hiroyuki
Konsoryu, 31(2), p.162 - 170, 2017/06
no abstracts in English
Tsuji, Nobumasa*; Ohashi, Kazutaka*; Tazawa, Yujiro*; Tachibana, Yukio; Ohashi, Hirofumi; Takamatsu, Kuniyoshi
FAPIG, (190), p.20 - 24, 2015/07
In a loss of forced cooling accident, decay heat in HTGRs must be removed by radiation, thermal conduction and natural convection. Passive heat removal performance is of primary concern for enhancing inherent safety features of HTGRs. Therefore, the thermal hydraulic analyses for normal operation and a loss of forced cooling accident are conducted by using thermal hydraulic CFD code. And further, a multi-hole type fuel block of MHTGR is also modeled and the flow and heat transfer characteristics are compared with a pin-in-block type fuel block.
Inagaki, Terumi*; Hatori, Masakazu*; Suzuki, Tomohiro*; Shiina, Yasuaki
Proceedings of International Conference on Advanced Optical Diagnostics in Fluids, Solids and Combustion (VSJ-SPIE '04) (CD-ROM), 9 Pages, 2004/12
no abstracts in English
Inagaki, Terumi*; Kaneko, Toshinobu*; Hatori, Masakazu*; Shiina, Yasuaki
Nihon Kikai Gakkai Rombunshu, B, 70(699), p.279 - 286, 2004/11
no abstracts in English
Takada, Shoji
Nuclear Engineering and Design, 233(1-3), p.185 - 195, 2004/10
Times Cited Count:6 Percentile:40.51(Nuclear Science & Technology)Experiments are carried out to investigate the effects of the natural convection of superheated gas as well as of the stand pipes on the temperature distributions of the components and the heat removal performance in the water-cooling panel system for the MHTGR for decay heat removal, and to verify the design and evaluation methods. The numerical results of the code THANPACST2 are compared with the experimental data to verify the numerical methods and axi-symmetric model proposed, which can simulate the three-dimensional configuration of the stand pipes on the upper head of the pressure vessel by using porous body cells. The experiments revealed that temperatures increased with elevation on the upper head, because the stand pipes restrict radiation heat transfer to the upper cooling panel and reduce the heat transfer area on the upper head which was superheated by natural convection of helium gas in the pressure vessel. The numerical methods were able to closely duplicate the pattern of the rising temperature profile with elevation around the top of the upper head.
Takenaga, Hidenobu; Oyama, Naoyuki; Fujita, Takaaki; Yamada, Hiroshi*; Nishimura, Kiyohiko*; Tanaka, Kenji*; Sakamoto, Ryuichi*
Annual Report of National Institute for Fusion Science; April 2003 - March 2004, P. 12, 2003/10
no abstracts in English
Takenaga, Hidenobu; Higashijima, Satoru; Oyama, Naoyuki; Bruskin, L. G.; Koide, Yoshihiko; Ide, Shunsuke; Shirai, Hiroshi; Sakamoto, Yoshiteru; Suzuki, Takahiro; Hill, K. W.*; et al.
Nuclear Fusion, 43(10), p.1235 - 1245, 2003/10
Times Cited Count:71 Percentile:88.53(Physics, Fluids & Plasmas)no abstracts in English
Takenaga, Hidenobu
Purazuma, Kaku Yugo Gakkai-Shi, 79(8), p.790 - 804, 2003/08
no abstracts in English
Shirai, Hiroshi
Purazuma, Kaku Yugo Gakkai-Shi, 79(7), p.691 - 705, 2003/07
Methods for heat transport analysis and heat transport simulation in toroidal plasmas are summarized on the basis of energy balance equation. Joule heating, NBI heating, RF heating and heating are briefly explained. Among the energy loss mechanism, the conduction loss and the radiation loss dominate in the core plasma region and the peripheral region, respectively. In tokamaks, the anomalous transport caused by microturbulence is much larger than the neoclassical transport. The other mechanisms of enhanced transport, the sawtooth oscillation and the magnetic island formation, are also shown.