Kaji, Daiya*; Morimoto, Koji*; Wakabayashi, Yasuo*; Takeyama, Mirei*; Yamaki, Sayaka*; Tanaka, Kengo*; Haba, Hiromitsu*; Huang, M.*; Murakami, Masashi*; Kanaya, Jumpei*; et al.
JPS Conference Proceedings (Internet), 6, p.030107_1 - 030107_4, 2015/06
Performance of the new gas-filled recoil ion separator GARIS-II was investigated using asymmetric Ne-induced fusion reactions. The use of He-H
mixture gas for the gas-filled magnet significantly reduced background scattered particles detected at the focal-plane Si detector, and increased a transmission of the asymmetric reaction products. A target-identification system was newly installed for efficient measurements of excitation functions without changing beam energy nor target.
Amemiya, Hiroshi*; Wada, Motoi*; Toyoda, Hirotaka*; Nakamura, Keiji*; Ando, Akira*; Uehara, Kazuya; Oyama, Koichiro*; Sakai, Osamu*; Tachibana, Kunihide*
Purazuma, Kaku Yugo Gakkai-Shi, 81(7), p.482 - 525, 2005/07
This article is asked to write by the Japan Society of Plasma Science and Nuclear Fusion Research. The probe diagnostics in fusion plasma is explaind for many readers of the Journal of Plasma and Fusion Research, who have much concerned on various aspects.In section one, the method to estimate the electron temperature and the density as well as the electron energy distribution function with the single probe is given. In section two, the method to estimate the ion temperature and the flow velocity with the double probe is given. The practical measurements are explained introducing the data obtained at JFT-2, JFT-2a and JFT-2M in JAERI tokamak.