Refine your search:     
Report No.
 - 
Search Results: Records 1-3 displayed on this page of 3
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Benchmark analyses on control rod worths of TRIGA reactor modeled in the ICSBEP handbook using continuous-energy Monte Carlo code MVP version 3

Yanagisawa, Hiroshi; Umeda, Miki; Motome, Yuiko; Murao, Hiroyuki

Proceedings of 12th International Conference on Nuclear Criticality Safety (ICNC2023) (Internet), 10 Pages, 2023/10

The benchmark analyses on the TRIGA reactor of the IEU-COMP-THERM-013 (ICT-013) in the ICSBEP handbook using the MVP version 3 code were carried out with the Japanese, US and European nuclear data libraries, including JENDL-5. The analyses on effective neutron multiplication factors (k$$_{eff}$$'s) were also performed for another TRIGA reactor defined in the ICT-003 as well as the ICT-013. As a result, it is confirmed that the calculated k$$_{eff}$$'s vary in the range of 0.8% with the libraries. The results also suggest that there might be unknown bias in the ICT-013 for the calculated k$$_{eff}$$'s. For the analyses on the control rod worths of the ICT-013, it is confirmed that differences in the worths among the libraries become smaller than those in k$$_{eff}$$'s. Most of the errors involved in k$$_{eff}$$'s are considered to be cancelled in the calculation of the worths since the worths are obtained by subtraction of the reciprocals of two sorts of k$$_{eff}$$'s. The differences in the worths by between the benchmark and alternative methods defined in the ICT-013 were tried to be examined from the aspect of the differences in horizontal flux distributions by between those methods. It is confirmed that the differences in the worths for two shim control rods, which are fully withdrawn at a delayed critical state, are well understood by that attempt, but on the other hand the differences are not sufficiently explained for a regulating control rod, which is partially inserted to attain delayed criticality.

JAEA Reports

Nuclear criticality benchmark analyses on TRIGA-type reactor systems by using continuous-energy Monte Carlo code MVP with JENDL-5

Yanagisawa, Hiroshi; Umeda, Miki; Motome, Yuiko; Murao, Hiroyuki

JAEA-Technology 2022-030, 80 Pages, 2023/02

JAEA-Technology-2022-030.pdf:2.57MB
JAEA-Technology-2022-030(errata).pdf:0.11MB

Nuclear criticality benchmark analyses were carried out for TRIGA-type reactor systems in which uranium-zirconium hydride fuel rods are loaded by using the continuous-energy Monte Carlo code MVP with the evaluated nuclear data library JENDL-5. The analyses cover two sorts of benchmark data, the IEU-COMP-THERM-003 and IEU-COMP-THERM-013 in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook, and effective neutron multiplication factors, reactivity worths for control rods etc. were calculated by JENDL-5 in comparison with those by the previous version of JENDL. As the results, it was confirmed that the effective neutron multiplication factors obtained by JENDL-5 were 0.4 to 0.6% greater than those by JENDL-4.0, and that there were no significant differences in the calculated reactivity worths by between JENDL-5 and JENDL-4.0. Those results are considered to be helpful for the confirmation of calculation accuracy in the analyses on NSRR control rod worths, which are planned in the future.

Journal Articles

Intercomparisons of benchmark calculations for the transmission of quasi-monoenergetic neutrons generated by 43- and 68-MeV protons through iron and concrete shield

Nakane, Yoshihiro; Nakashima, Hiroshi; Nakao, Noriaki*; Ueki, Kotaro*

Proc. of 3rd Workshop on Simulating Accelerator Radiation Environments (SARE3), p.334 - 342, 1997/00

no abstracts in English

3 (Records 1-3 displayed on this page)
  • 1