Kugo, Teruhiko; Kojima, Kensuke; Ando, Masaki; Okajima, Shigeaki; Mori, Takamasa; Takeda, Toshikazu*; Kitada, Takanori*; Matsuoka, Shogo*
Proceedings of 2005 International Congress on Advances in Nuclear Power Plants (ICAPP '05) (CD-ROM), 10 Pages, 2005/05
We have preliminarily evaluated the reduction of prediction errors of the core characteristics of the breeding light water reactor core based on the bias factor method by utilizing the FCA critical experiments carried out for MOX fueled tight lattice light water reactor cores. The prediction uncertainty of k is reduced from 0.62% to 0.39% by utilizing the FCA-XV-2 (65V) result. As for the reaction rate ratio of
U capture and
Pu fission, it is found that the FCA XXII-1 (95V) and XV (95V) results are suitable for the upper core and the upper blanket of the real core and the FCA XXII-1 (65V) and XV-2 (65V) results are suitable for the lower core and the internal blanket.