検索結果: 3 件中 1件目~3件目を表示
  • 1

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Development of probabilistic risk assessment methodology of decay heat removal function against combination hazard of low temperature and snow for sodium-cooled fast reactors

西野 裕之; 山野 秀将; 栗坂 健一

Mechanical Engineering Journal (Internet), 5(4), p.18-00079_1 - 18-00079_17, 2018/08

A probabilistic risk assessment (PRA) should be performed not only for earthquake and tsunami which are major natural events in Japan but also for other natural external hazards. However, PRA methodologies for other external hazards and their combination have not been sufficiently developed. This study is aimed at developing a PRA methodology for the combination of low temperature and snow for a sodium-cooled fast reactor which uses the ambient air as its ultimate heat sink to remove decay heat under accident conditions. The annual exceedance probabilities of low temperature and of snow can be statistically estimated based on the meteorological records of temperature, snow depth and daily snowfall depth. To identify core damage sequence, an event tree was developed by considering the impact of low temperature and snow on decay heat removal systems (DHRSs), e.g., a clogged intake and/or outtake for a DHRS and for an emergency diesel generator, an unopenable door on necessary access routes due to accumulated snow, failure of intake filters due to accumulated snow, and possibility of water freezing in cooling circuits. Recovery actions (i.e., snow removal and filter replacement) to prevent loss of DHRS function were also considered in developing the event tree. Furthermore, considering that a dominant contributor to snow risk can be failure of snow removal around intakes and outtakes caused by loss of the access routes, this study has investigated effects of electric heaters installed around the intakes and outtakes as an additional countermeasure. By using the annual exceedance probabilities and failure probabilities, the event tree was quantified. The result showed that a dominant core damage sequence caused by a snow and low temperature combination hazard is the failure of the electric heaters and the loss of the access routes for snow removal due to low temperature and snowfall which last for a day, and daily snowfall depth of 2 m/day.

論文

確率論的安全評価手法を用いた事故故障事例評価に基づく定量的なリスクトレンド; 米国原子力規制委員会による「前兆事象評価」結果に基づく分析

渡邉 憲夫

日本原子力学会和文論文誌, 3(4), p.396 - 406, 2004/12

米国原子力規制委員会は、原子力発電所で発生した事故・故障事例の中から炉心損傷に至る可能性のある事象を同定するために、確率論的安全評価手法を用いた前兆事象評価(ASP評価)を行っており、これまでに、数多くのリスク上重要な事象を特定している。ASP評価の結果には、原子力発電所に対してリスク上重要な知見を導出したり、原子力発電所におけるリスクのトレンドを監視するための有用な情報が含まれている。本研究では、ASP評価結果をもとに、前兆事象の発生頻度と年間炉心損傷確率という2つの定量的なリスク指標を用いて、そのトレンドを分析した。その結果、米国における原子力発電所のリスクは減少傾向にあり、また、リスク上重要な事象の発生頻度も著しく低下していることが明らかとなった。さらに、この分析を通して、原子力発電所におけるリスクのトレンドを定量的に示すことができることを実証し、今後のリスクトレンドを監視するうえで、この2つの指標の有用性を確認することができた。

報告書

地震時システム信頼性解析コードSECOM2の使用手引

内山 智曜; 及川 哲邦; 近藤 雅明; 渡辺 裕一*; 田村 一雄*

JAERI-Data/Code 2002-011, 205 Pages, 2002/03

JAERI-Data-Code-2002-011.pdf:8.52MB

本報告書は、地震に対する原子力発電所の確率論的安全評価(PSA)におけるタスクの1つであるシステム信頼性解析を目的として原研で開発してきた地震時システム信頼性解析コードSECOM2の使用手引としてまとめたものである。SECOM2コードには、炉心損傷または任意の頂上事象の発生条件を表すフォールトツリーとそれを構成する機器等の耐力や応答に関する情報、地震危険度曲線等を入力として、応答係数法に基づいた地震動レベルごとの機器損傷確率やシステム機能喪失確率の計算,当該サイトでの地震危険度曲線を組み合わせた事故シーケンスの発生頻度や炉心損傷頻度の計算,さまざまな指標を用いた重要度評価,不確実さ解析,応答及び耐力の相関性を考慮した炉心損傷頻度の評価等を行う機能がある。本報告書では、これらSECOM2の機能について計算方法を示し、各機能を用いる際の具体的な使用方法について説明する。

3 件中 1件目~3件目を表示