Refine your search:     
Report No.
 - 
Search Results: Records 1-19 displayed on this page of 19
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Operation, maintenance and technical development of cryogenic hydrogen system at MLF (JFY2018$$sim$$2022)

Aso, Tomokazu; Ariyoshi, Gen; Muto, Hideki*; Tanaka, Shigeto*

JAEA-Technology 2025-005, 51 Pages, 2025/10

JAEA-Technology-2025-005.pdf:2.47MB

The cryogenic hydrogen system of the J-PARC center is one of the most important pieces equipment, which is a refrigeration system for moderating (cooling) the high energy neutrons generated the spallation neutron source of the Material and Life Science Experimental Facility (MLF) that is used by many users from Japan and abroad. Since the first operation of the MLF for neutron use in 2008, the cryogenic hydrogen system has been continuously operated and maintained, and related technology development has been carried out. This report summarized these activities over the past five years.

JAEA Reports

Improvement of accumulator in cryogenic hydrogen system used for 1-MW pulsed spallation neutron source

Aso, Tomokazu; Tatsumoto, Hideki*; Otsu, Kiichi*; Kawakami, Yoshihiko*; Komori, Shinji*; Muto, Hideki*; Takada, Hiroshi

JAEA-Technology 2019-013, 77 Pages, 2019/09

JAEA-Technology-2019-013.pdf:5.59MB

At Materials and Life Science experimental Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC), a 1-MW pulsed spallation neutron source is equipped with a cryogenic hydrogen system which circulates liquid hydrogen (20 K and 1.5 MPa) to convert high energy neutrons generated at a mercury target to cold neutrons at three moderators with removing nuclear heat of 3.8 kW deposited there. The cryogenic system includes an accumulator with a bellows structure in order to absorb pressure fluctuations generated by the nuclear heat deposition in the system. Welded inner bellows of the first accumulator was failured during operation, forcing us to improve the accumulator to have sufficient pressure resistance and longer life-time. We have developed elemental technologies for manufacturing welded bellows of the accumulator by a thick plate with high pressure resistance, succeeding to find optimum welding conditions. We fabricated a prototype bellows block and carried out an endurance test by adding a pressure change of 2 MPa repeatedly. As a result, the prototype bellows was successfully in use exceeding the design life of 10,000 times. Since distortions given during welding and assembling affect functionality and lifetime of the bellows, we set the levelness of each element of the bellows as within 0.1$$^{circ}$$. The improved accumulator has already been in operation for about 25,000 hours as of January 2019, resulting that the number of strokes reached to 16,000. In July 2018, we demonstrated that the accumulator could suppress the pressure fluctuation generated by the 932 kW beam injection as designed. As current operational beam power is 500 kW, the current cryogenic hydrogen system could be applicable for stable operation at higher power in the future.

Journal Articles

Recovery of helium refrigerator performance for cryogenic hydrogen system at J-PARC MLF

Aso, Tomokazu; Teshigawara, Makoto; Hasegawa, Shoichi; Muto, Hideki; Aoyagi, Katsuhiro; Nomura, Kazutaka; Takada, Hiroshi

Journal of Physics; Conference Series, 1021(1), p.012085_1 - 012085_4, 2018/06

BB2016-1899.pdf:0.54MB

 Times Cited Count:0 Percentile:0.00(Nuclear Science & Technology)

Journal Articles

Materials and Life Science Experimental Facility at the Japan Proton Accelerator Research Complex, 1; Pulsed spallation neutron source

Takada, Hiroshi; Haga, Katsuhiro; Teshigawara, Makoto; Aso, Tomokazu; Meigo, Shinichiro; Kogawa, Hiroyuki; Naoe, Takashi; Wakui, Takashi; Oi, Motoki; Harada, Masahide; et al.

Quantum Beam Science (Internet), 1(2), p.8_1 - 8_26, 2017/09

At the Japan Proton Accelerator Research Complex (J-PARC), a pulsed spallation neutron source provides neutrons with high intensity and narrow pulse width to promote researches on a variety of science in the Materials and life science experimental facility. It was designed to be driven by the proton beam with an energy of 3 GeV, a power of 1 MW at a repetition rate of 25 Hz, that is world's highest power level. A mercury target and three types of liquid para-hydrogen moderators are core components of the spallation neutron source. It is still on the way towards the goal to accomplish the operation with a 1 MW proton beam. In this paper, distinctive features of the target-moderator-reflector system of the pulsed spallation neutron source are reviewed.

Journal Articles

Experimental results of ITER cold circulators towards the performance demonstration

Bhattacharya, R.*; Vaghela, H.*; Sarkar, B.*; Patel, P.*; Das, J.*; Srinivasa, M.*; Isono, Takaaki; Kawano, Katsumi

IOP Conference Series; Materials Science and Engineering, 171, p.012058_1 - 012058_8, 2017/03

JAEA Reports

Characterization of cryogenically cooled silicon crystals, for the double-crystal monochromator on BL11XU at SPring-8

Tozawa, Kazukiyo*; Kiriyama, Koji*; Mitsui, Takaya; Shiwaku, Hideaki; Harami, Taikan

JAERI-Tech 2004-041, 27 Pages, 2004/03

JAERI-Tech-2004-041.pdf:5.11MB

Liquid-N$$_{2}$$-cooled Si crystals replaced water-cooled diamond crystals for the double-crystal monochromator on BL11XU at SPring-8. To use the whole energy from 6 keV to 70 keV, we developed the system of dual symmetric Si geometry, Si(111)/Si(311), which can be switched by a horizontal translation (X) stage perpendicular to the beam axis. The off-line experiment was performed to estimate the degree of the crystal strain, which may arise from the way of assembling in the crystal holder. With MoK$$alpha$$$$_{1}$$, rocking curves from the crystals were measured for the second crystal of the double-crystal diffractometer of parallel setting. Each of the observed full-width at half maximum (FWHM) was almost constant and identical to the calculated value wherever X-rays hit on the crystal surface. By the use of synchrotron radiation from the undulator the crystals were tested and then the characterization was performed. The observed intensities and rocking curves resulted in that each crystal was good for BL11XU and that the performance of X-ray reflection was improved.

Journal Articles

Current status of the JAERI superconducting RF linac-based free-electron laser

Minehara, Eisuke; Hajima, Ryoichi; Sawamura, Masaru; Nagai, Ryoji; Kikuzawa, Nobuhiro; Nishimori, Nobuyuki

Proceedings of 28th Linear Accelerator Meeting in Japan, p.31 - 32, 2003/08

Current status of the JAERI superconducting RF linac driven free-electron laser has been reported to describe some details of the FEL device and application researches. In the presentation, several progresses and achievements itimized below have been reproted briefly. Firstly a semi-perpetual, non-stop and continous operation of the JAERI cryogenic and refrigeration system is only available in the world for the JAERI superconducting linac-based FEL. Secondly a conceptual design and each vital component of the ERL(energy recovery linac) light souce has recently been developed and progressed quickly as the next-generation light source. Thirdly,large-scaled industrial applications have been briefly reported here.

JAEA Reports

Setup of the cryogenic cooling system on BL11XU at SPring-8

Kiriyama, Koji*; Shiwaku, Hideaki; Tozawa, Kazukiyo*

JAERI-Tech 2003-061, 21 Pages, 2003/07

JAERI-Tech-2003-061.pdf:3.25MB

Cryogenically cooled monochromator equipped with circulated-liquid-nitrogen cooling system has been developed on JAERI beam-line, BL11XU, at SPring-8. This cooling system has improved the performance of X-ray reflection. The system has difficulty for the operation because of a lack of the manual. So, it is required to establish a systematic guide of the system. Here we report a manual with fruitful know-how to operate the cryogenic cooling system on BL11XU safely and easily. The new manual is wholly tabulated and shows comments, instructions, and valve conditions in all one-step. The operator, by using this manual, can manipulate the system with no misoperation.

Journal Articles

Cryogenic system characteristics for the transitional heat disturbance of the CS model coil

Kawano, Katsumi; Hamada, Kazuya; Matsui, Kunihiro; Hara, Eiji*; Kato, Takashi; CS Model Coil Test Group

Teion Kogaku, 36(6), p.381 - 388, 2001/06

no abstracts in English

Journal Articles

Design and construction of long cryogenic piping lines

Kawano, Katsumi; Kato, Takashi; ; Matsui, Kunihiro; Hiyama, Tadao; ; ; ; Otsu, K.*; ; et al.

Proc. of 16th Int. Cryogenic Engineering Conf. /Int. Cryogenic Materials Conf., 0, 4 Pages, 1996/00

no abstracts in English

Journal Articles

Discussion for a helium cryogenic system automatic control

Kato, Takashi

Heisei-4-Nendo Reito Bukai Nenkan Koenshu, 0, p.25 - 30, 1993/00

no abstracts in English

Journal Articles

Cryogenic system design and its component development for Fusion Experimental Reactor(FER)

Kato, Takashi; Tada, Eisuke; Hiyama, Tadao; Kawano, Katsumi; ; ; ; ; Shimamoto, Susumi

Fusion Technology 1990, p.1535 - 1539, 1991/00

no abstracts in English

JAEA Reports

Joint operation of TSTA under the collaboration between JAERI and DOE-LANL; An Integrated loop operation with 100-g tritium in July 1988

Okuno, Kenji; Enoeda, Mikio; ; ; Yoshida, Hiroshi; Naruse, Yuji; Anderson, J. L.*; Bartlit, J. R.*; Sherman, R. H.*; R.V.Carlson*; et al.

JAERI-M 90-028, 73 Pages, 1990/02

JAERI-M-90-028.pdf:1.51MB

no abstracts in English

Journal Articles

Journal Articles

Cryogenic system component development for the fusion experimental reactor at JAERI

Kato, Takashi; ; ; Hiyama, Tadao; Kawano, Katsumi;

Transactions of the American Nuclear Society, 52, p.313 - 314, 1986/00

no abstracts in English

JAEA Reports

Journal Articles

Preliminary design of a fusion reactor fuel cleanup system by the palladium alloy membrane method

; Konishi, Satoshi; Naruse, Yuji

Nucl.Technol./Fusion, 3, p.471 - 484, 1983/00

no abstracts in English

Oral presentation

The Cause of performance degradation of cryogenic hydrogen system at J-PARC; A Little fire burns up a great deal of corn

Aso, Tomokazu; Teshigawara, Makoto; Ariyoshi, Gen; Haga, Katsuhiro

no journal, , 

Oral presentation

Performance degradation of helium refrigerator for cryogenic hydrogen system at J-PARC

Aso, Tomokazu; Teshigawara, Makoto; Hasegawa, Shoichi; Muto, Hideki*; Aoyagi, Katsuhiro*; Takada, Hiroshi

no journal, , 

19 (Records 1-19 displayed on this page)
  • 1