Watakabe, Tomoyoshi; Yamamoto, Tomohiko; Okamura, Shigeki; Miyazaki, Masashi; Miyagawa, Takayuki; Uchita, Masato*; Hirayama, Tomoyuki*; Somaki, Takahiro*; Yukawa, Masaki*; Fukasawa, Tsuyoshi*; et al.
Proceedings of ASME 2024 Pressure Vessels & Piping Conference (PVP 2024) (Internet), 10 Pages, 2024/07
To secure the seismic safety of the thin-walled mechanical components and piping under a severe design earthquake level, employing a three-dimensional (3D) seismic isolation system has been planned in a sodium-cooled fast reactor. The development results of the 3D isolation system have been reported in previous papers so far. Its update is reported in Part 7 to Part 9. Part 7 describes the overview of the development, the test plan of the isolation system in the assembled state of each element, and the performance of individual isolation elements. In part 8, the performance of the isolation device that each element was assembled into was investigated through loading tests. Part 9 reports analytical studies by an analysis model validated based on the insight of the test results.