Applicability study on existing dosimetry systems to high-power Bremsstrahlung irradiation

Mehta, K.*; Kojima, Takuji; Sunaga, Hiromi

Radiation Physics and Chemistry, 68(6), p.959 - 962, 2003/12

 Times Cited Count:3 Percentile:26.72(Chemistry, Physical)

Applicability of the existing dosimetry systems to high-power Bremsstrahlung irradiation was investigated through a dose intercomparison study, where several dosimeters were irradiated in the dose range 4-12 kGy in identical polyethylene phantoms in a Bremsstrahlung beam obtained from a 5-MeV electron accelerator. Included in the study were alanine dosimeters molded by three different binders, three types of liquid dosimeters:ceric-cerous, dichromate and ethanol-chlorobenzen (ECB), and glutamine powder. The dosimeter responses for Bremsstrahlung radiation were analyzed at the issuing laboratories, and the dose values determined using calibration based on cobalt-60 $$gamma$$-ray irradiation. Dose values for all the three dose levels for all dosimetry systems were in good agreement of better than 3%. The results of the study demonstrate that these existing dosimetry systems have a potential for application to high-power Bremsstrahlung irradiation.

JAEA Reports

Development of the JAERI Computational Dosimetry System (JCDS) for boron neutron capture therapy (Cooperative research)

Kumada, Hiroaki; Yamamoto, Kazuyoshi; Torii, Yoshiya; Matsumura, Akira*; Yamamoto, Tetsuya*; Nose, Tadao*; Nakagawa, Yoshinobu*; Kageji, Teruyoshi*; Uchiyama, Junzo

JAERI-Tech 2003-002, 49 Pages, 2003/03

JAERI-Tech-2003-002.pdf:5.22MB

no abstracts in English

JAEA Reports

Production of a faithful realistic phantom to human head and thermal neutron flux measurement on the brain surface (Cooperative research)

Yamamoto, Kazuyoshi; Kumada, Hiroaki; Kishi, Toshiaki; Torii, Yoshiya; Endo, Kiyoshi*; Yamamoto, Tetsuya*; Matsumura, Akira*; Uchiyama, Junzo; Nose, Tadao*

JAERI-Tech 2002-092, 23 Pages, 2002/12

JAERI-Tech-2002-092.pdf:5.22MB

Thermal neutron flux is determined using the gold wires in current BNCT irradiation, so evaluation of arbitrary points after the irradiation is limited in the quantity of these detectors. In order to make up for the weakness, dose estimation of a patient is simulated by a computational dose calculation supporting system. In another way without computer simulation, a medical irradiation condition can be replicate experimentally using of realistic phantom which was produced from CT images by rapid prototyping technique. This phantom was irradiated at a same JRR-4 neutron beam as clinical irradiation condition of the patient and the thermal neutron distribution on the brain surface was measured in detail. This experimental evaluation technique using a realistic phantom is applicable to in vitro cell irradiation experiments for radiation biological effects as well as in-phantom experiments for dosimetry under the nearly medical irradiation condition of patient.

Journal Articles

Verification of the JAERI computational dosimetry system for neutron capture therapy

Kumada, Hiroaki; Matsumura, Akira*; Nakagawa, Yoshinobu*; Yamamoto, Tetsuya*; Yamamoto, Kazuyoshi; Torii, Yoshiya

Research and Development in Neutron Capture Therapy, p.529 - 534, 2002/09

no abstracts in English

Journal Articles

Comparison of dosimetry by the realistic patient head phantom and by the patient's brain, and the JCDS calculation; A Clinical dosimetry study

Endo, Kiyoshi*; Matsumura, Akira*; Yamamoto, Tetsuya*; Nose, Tadao*; Yamamoto, Kazuyoshi; Kumada, Hiroaki; Kishi, Toshiaki; Torii, Yoshiya; Kashimura, Takanori*; Otake, Shinichi*

Research and Development in Neutron Capture Therapy, p.425 - 430, 2002/09

Using the Rapid Prototyping Technique, we produced a realistic phantom as a formative model of a patient head. This realistic phantom will contribute to verification of our planning system. However, cross-correlation among the calculations using the JAERI Computational Dosimetry System (JCDS), the realistic phantom, and the in vivo measurements were not fully completed because of the difficulty involved in modeling a post-surgical brain and a thermal neutron shield. The experimental simulation technique using the realistic phantom is a useful tool for more reliable dose planning for the intraoperative BNCT.

Journal Articles

Optimization of intraoperative (IO)BNCT; Pre-irradiation surgical technique and 2-D dosimetry in surgical field

Yasuda, Susumu*; Yamamoto, Tetsuya*; Matsumura, Akira*; Shibata, Yasushi*; Akutsu, Hiroyoshi*; Matsushita, Akira*; Nakai, K.*; Nose, Tadao*; Yamamoto, Kazuyoshi; Kumada, Hiroaki; et al.

Proceedings of 9th International Symposium on Neutron Capture Therapy for Cancer, p.171 - 172, 2000/10

no abstracts in English

Journal Articles

Characterization and evaluation studies on some JAERI dosimetry systems

Kojima, Takuji; Sunaga, Hiromi; Tachibana, Hiroyuki; Takizawa, Haruki; Tanaka, Ryuichi

IAEA-TECDOC-156, p.91 - 98, 2000/06

no abstracts in English

Journal Articles

Characterization and performance study of high-dose $$^{60}$$Co $$gamma$$-ray calibration laboratory for radiation processing

Tachibana, Hiroyuki; Kojima, Takuji; ; ; Yotsumoto, Keiichi; Tanaka, Ryuichi

Radioisotopes, 48(4), p.247 - 256, 1999/04

no abstracts in English

8 (Records 1-8 displayed on this page)