Refine your search:     
Report No.
 - 
Search Results: Records 1-6 displayed on this page of 6
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Experimental study on local interfacial parameters in upward air-water bubbly flow in a vertical 6$$times$$6 rod bundle

Han, X.*; Shen, X.*; Yamamoto, Toshihiro*; Nakajima, Ken*; Sun, Haomin; Hibiki, Takashi*

International Journal of Heat and Mass Transfer, 144, p.118696_1 - 118696_19, 2019/12

 Times Cited Count:18 Percentile:68.89(Thermodynamics)

Journal Articles

Some characteristics of gas-liquid two-phase flow in vertical large-diameter channels

Shen, X.*; Schlegel, J. P.*; Hibiki, Takashi*; Nakamura, Hideo

Nuclear Engineering and Design, 333, p.87 - 98, 2018/07

 Times Cited Count:11 Percentile:30.77(Nuclear Science & Technology)

Journal Articles

Experimental study on interfacial area transport of two-phase bubbly flow in a vertical large-diameter square duct

Shen, X.*; Sun, Haomin; Deng, B.*; Hibiki, Takashi*; Nakamura, Hideo

International Journal of Heat and Fluid Flow, 67(Part A), p.168 - 184, 2017/10

 Times Cited Count:17 Percentile:61.61(Thermodynamics)

An experimental study on upward bubbly air-water flows in a vertical large-diameter square duct have been performed by mainly using four-sensor probes. Local measurements of interfacial area concentration (IAC), void fraction, 3D bubble velocity vector and bubble diameter at 3 axial positions were conducted. Although the interfacial area transport equation (IATE) and its bubble coalescence and breakup models have already played an important role in predicting the IAC in general two-phase flow fields, they are mainly developed based on the two-phase flow experimental data taken in round pipes or small diameter channels. To confirm their usability in large-diameter square duct, this study has evaluated the 1D one-group IATE with its 6 sets of bubble coalescence and breakup models with the presently-obtained database. It was found the relative error between the best prediction and the database was 25%.

Journal Articles

Axial flow characteristics of bubbly flow in a vertical large-diameter square duct

Shen, X.*; Sun, Haomin; Deng, B.*; Hibiki, Takashi*; Nakamura, Hideo

Proceedings of 17th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-17) (USB Flash Drive), 14 Pages, 2017/09

An experimental study on the upward bubbly air-water flows in a vertical large-diameter square duct have been performed by using four-sensor probes. The four-sensor probe were applied in the local measurements at 3 axial positions along the flow direction to obtain interfacial area concentration, 3-D bubble velocity vector and bubble diameter. The obtained void fraction, interfacial area concentration, 3-D bubble velocity vector and bubble diameter provided valuable insight into the flow structure and will serve as a valuable database to develop the mechanistic models for interfacial area transport equation sources and sinks.

Journal Articles

Multi-dimensional gas-liquid two-phase flow in vertical large-diameter channels

Shen, X.*; Schlegel, J. P.*; Hibiki, Takashi*; Nakamura, Hideo

Proceedings of 2017 Japan-US Seminar on Two-Phase Flow Dynamics (JUS 2017), 6 Pages, 2017/06

Journal Articles

Gas-liquid bubbly flow structure in a vertical large-diameter square duct

Shen, X.*; Sun, Haomin; Deng, B.*; Hibiki, Takashi*; Nakamura, Hideo

Progress in Nuclear Energy, 89, p.140 - 158, 2016/05

 Times Cited Count:24 Percentile:89.96(Nuclear Science & Technology)

An experimental study was performed on the local structure of upward air-water two-phase flow in a vertical large diameter square duct by using a four-sensor probe. The four-sensor probe method classifying spherical and non-spherical bubbles was applied as a key measurement way to obtain local parameters such as 3-D bubble velocity vector, bubble diameter and interfacial area concentration. Both the local void fraction and interfacial area concentration indicated radial core-peak and wall-peak distributions at low and high liquid flow rates respectively. The 2 components of the bubble velocity vector in the cross-section revealed that there exists a rotating secondary flow in the octant symmetric triangular area and the magnitude of the rotating secondary flow increases with the liquid flow rate. Some of constitutive correlations of drift-flux model and interfacial area concentration are reviewed to study their predictabilities against the present data.

6 (Records 1-6 displayed on this page)
  • 1