Urushidate, Tadayuki*; Yoda, Tomoyuki; Otani, Shuichi*; Yamaguchi, Toshio*; Kunii, Nobuaki*; Kuriki, Kazuki*; Fujiwara, Kenso; Niizato, Tadafumi; Kitamura, Akihiro; Iijima, Kazuki
JAEA-Review 2022-023, 8 Pages, 2022/09
After the accident of the Fukushima Daiichi Nuclear Power Station, the Japan Atomic Energy Agency has newly set up a laboratory in Fukushima and started measuring radioactivity concentrations of environmental samples. In October 2015, Fukushima Radiation Measurement Group has been accredited the ISO/IEC 17025 standard by the Japan Accreditation Board (JAB) as a testing laboratory for radioactivity analysis (Cs, Cs) based on Gamma-ray spectrometry with germanium semiconductor detectors. The laboratory has measured approximately 60,000 of various environmental samples at the end of March 2022. The laboratory quality control and measurement techniques have been accredited by regular surveillance of JAB. In September 2019, the laboratory renewed accreditation as a testing laboratory for radioactivity analysis.
Mikami, Satoshi; Tanaka, Hiroyuki*; Okuda, Naotoshi*; Sakamoto, Ryuichi*; Ochi, Kotaro; Uno, Kiichiro*; Matsuda, Norihiro; Saito, Kimiaki
Nihon Genshiryoku Gakkai Wabun Rombunshi, 20(4), p.159 - 178, 2021/12
In order to know the background radiation level where the area affected by the Fukushima Daiichi Nuclear Power Plant accident in 2011, terrestrial gamma rays had been measured by using portable germanium detectors repeatedly from 2013 through 2019, at 370 locations within 80 km radius area centered on the Fukushima Daiichi Nuclear Power Plant. Radioactive concentrations of Uranium 238, Thorium 232, Potassium 40 and kerma rates in air due to terrestrial gamma rays were obtained at those locations based on the method of ICRU report 53. Averaged concentrations of U, Th and K were 18.8, 22.7, 428 Bq/kg, respectively, and kerma rate in air over the area was found to be 0.0402 Gy/h. The obtained kerma rates in air were compared to those reported in literatures. It was confirmed that the data were correlated with each other, and were agreed within the range of their uncertainty. This is because the kerma rate in air due to terrestrial gamma rays is depend on geology. The similar trend to previous findings was observed that the kerma rate in air at locations geologically classified as Mesozoic era, Granite and Rhyolite were statistically significantly higher than the others.
Yamada, Takashi*; Asai, Masato; Yonezawa, Chushiro*; Kakita, Kazutoshi*; Hirai, Shoji*
Radioisotopes, 69(9), p.287 - 297, 2020/09
We have confirmed that the commercially available Japanese "standard" gamma-ray analysis programs do not consider the effect of sample volume in calculating true coincidence summing (TCS) corrections, which results in underestimation of Cs radioactivity in cylindrical volume samples. In this work, we have developed and examined a practical TCS correction method for general Ge detectors which consider the effect of sample volume properly, and have confirmed that this method can reduce the Cs radioactivity underestimation to less than 1%.
Kaburagi, Masaaki; Shimazoe, Kenji*; Otaka, Yutaka*; Uenomachi, Mizuki*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*; et al.
Nuclear Instruments and Methods in Physics Research A, 971, p.164118_1 - 164118_8, 2020/08
Times Cited Count:7 Percentile:64.73(Instruments & Instrumentation)Nakamura, Shoji; Shibahara, Yuji*; Kimura, Atsushi; Iwamoto, Osamu; Uehara, Akihiro*; Fujii, Toshiyuki*
Journal of Nuclear Science and Technology, 57(4), p.388 - 400, 2020/04
Times Cited Count:3 Percentile:30.79(Nuclear Science & Technology)The thermal-neutron capture cross-section () and resonance integral(I) were measured for the Cs(n,)Cs reaction by an activation method and mass spectrometry. We used Cs contained as an impurity in a normally available Cs standard solution. An isotope ratio of Cs and Cs in a standard Cs solution was measured by mass spectrometry to quantify Cs. The analyzed Cs samples were irradiated at the hydraulic conveyer of the research reactor in Institute for Integral Radiation and Nuclear Science, Kyoto University. Wires of Co/Al and Au/Al alloys were used as neutron monitors to measure thermal-neutron fluxes and epi-thermal Westcott's indices at an irradiation position. A gadolinium filter was used to measure the , and a value of 0.133 eV was taken as the cut-off energy. Gamma-ray spectroscopy was used to measure induced activities of Cs, Cs and monitor wires. On the basis of Westcott's convention, the and I values were derived as 8.570.25 barn, and 45.33.2 barn, respectively. The obtained in the present study agreed within the limits of uncertainties with the past reported value of 8.30.3 barn.
Nakamura, Shoji; Kimura, Atsushi; Iwamoto, Osamu; Shibahara, Yuji*; Uehara, Akihiro*; Fujii, Toshiyuki*
KURNS Progress Report 2018, P. 106, 2019/08
Under the ImPACT project, the neutron capture cross-section measurements of Cesium-135 (Cs) among the long-lived fission products have been performed at Kyoto University. This paper reports measurements of the thermal-neutron capture cross-section of Cs at the Kyoto University Research Reactor (KUR).
Nakamura, Shoji; Kitatani, Fumito; Kimura, Atsushi; Uehara, Akihiro*; Fujii, Toshiyuki*
Journal of Nuclear Science and Technology, 56(6), p.493 - 502, 2019/06
Times Cited Count:5 Percentile:47.59(Nuclear Science & Technology)The thermal-neutron capture cross-section()and resonance integral(I) were measured for the Np(n,)Np reaction by an activation method. A method with a Gadolinium filter, which is similar to the Cadmium difference method, was used to measure the with paying attention to the first resonance at 0.489 eV of Np, and a value of 0.133 eV was taken as a cut-off energy. Neptunium-237 samples were irradiated at the pneumatic tube of the Kyoto University Research Reactor in Institute for Integral Radiation and Nuclear Science, Kyoto University. Wires of Co/Al and Au/Al alloys were used as monitors to determine thermal-neutron fluxes and epi-thermal Westcott's indices at an irradiation position. A -ray spectroscopy was used to measure activities of Np, Np and neutron monitors. On the basis of Westcott's convention, the and I values were derived as 186.96.2 barn, and 100990 barn, respectively.
Sanada, Yukihisa
Nihon Genshiryoku Gakkai-Shi ATOMO, 59(7), p.418 - 422, 2017/07
no abstracts in English
; Oi, Yoshihiro; Taki, Mitsumasa; Kawasaki, Katsuya; Yoshida, Makoto
Applied Radiation and Isotopes, 50(6), p.1057 - 1061, 1999/00
Times Cited Count:8 Percentile:53.51(Chemistry, Inorganic & Nuclear)no abstracts in English
; ; Kitao, Kensuke*
JAERI-M 94-059, 112 Pages, 1994/03
no abstracts in English
JAERI-M 83-222, 38 Pages, 1983/12
no abstracts in English
JAERI-M 82-074, 37 Pages, 1982/07
no abstracts in English
Matsuura, Shojiro; ; ; ; Umezawa, Hirokazu;
Journal of Nuclear Science and Technology, 12(1), p.24 - 34, 1975/01
Times Cited Count:23no abstracts in English
Ji, Y.-Y.*; Mikami, Satoshi; Hong, B. S.*; Sanada, Yukihisa; Jang, M.*; Ochi, Kotaro; Nakama, Shigeo
no journal, ,