Nakamura, Shoji; Shibahara, Yuji*; Endo, Shunsuke; Rovira Leveroni, G.; Kimura, Atsushi
Journal of Nuclear Science and Technology, 62(3), p.300 - 307, 2025/03
Times Cited Count:0 Percentile:0.00(Nuclear Science & Technology)Nakamura, Shoji; Shibahara, Yuji*; Endo, Shunsuke; Kimura, Atsushi
Journal of Nuclear Science and Technology, 59(11), p.1388 - 1398, 2022/11
Times Cited Count:1 Percentile:14.76(Nuclear Science & Technology)The present study selected Np among radioactive nuclides and aimed to measure the thermal-neutron capture cross-section for
Np in a well-thermalized neutron field by an activation method. A
Np standard solution was used for irradiation samples. A thermal-neutron flux at an irradiation position was measured with neutron flux monitors:
Sc,
Co,
Mo,
Ta and
Au. The
Np sample and flux monitors were irradiated together for 30 minutes in the graphite thermal column equipped with the Kyoto University Research Reactor. The similar irradiation was carried out twice. After the irradiations, the
Np samples were quantified using 312-keV gamma ray emitted from
Pa in a radiation equilibrium with
Np. The reaction rates of
Np were obtained from gamma-ray peak net counts given by
Np, and then the thermal-neutron capture cross-section of
Np was found to be 173.8
4.4 barn by averaging the results obtained by the two irradiations. The present result was in agreement with the reported data given by a time-of-flight method within the limit of uncertainty.
Nakamura, Shoji; Endo, Shunsuke; Kimura, Atsushi; Shibahara, Yuji*
KURNS Progress Report 2021, P. 93, 2022/07
In terms of nuclear transmutation studies of minor actinides in nuclear wastes, the present work selected Np among them and aimed to measure the thermal-neutron capture cross-section of
Np using a well-thermalized neutron field by a neutron activation method because there have been discrepancies among reported cross-section data. A
Np standard solution was used for irradiation samples. The thermal-neutron flux at an irradiation position was measured with flux monitors:
Sc,
Co,
Mo,
Ta and
Au. The
Np sample was irradiated together with the flux monitors for 30 minutes in the graphite thermal column equipped in the Kyoto University Research Reactor. The similar irradiation was repeated once more to confirm the reproducibility of the results. After irradiation, the
Np samples were quantified using 312-keV gamma-ray emitted from
Pa in radiation equilibrium with
Np. The reaction rates of
Np were obtained from the peak net counts of gamma-rays emitted from generated
Np, and then the thermal-neutron capture cross-section of
Np was found to be 173.8
4.7 barn by averaging the results obtained by the two irradiations. The present result was in agreement with the reported data given by a time-of-flight method within a limit of uncertainty.