Refine your search:     
Report No.
 - 
Search Results: Records 1-3 displayed on this page of 3
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Evaluation of detectability of pump/diagrid link rupture in pool-type sodium-cooled fast reactor

Onoda, Yuichi; Uchita, Masato*; Tokizaki, Minako*; Okazaki, Hitoshi*

Proceedings of 29th International Conference on Nuclear Engineering (ICONE 29) (Internet), 6 Pages, 2022/08

The safety analyses were carried out to confirm the sufficiency of the function of the plant protection system against the pump/diagrid link rupture. The target plant is a pool-type SFR of about 600 MWe class equipped with an axially homogeneous core currently under development in Japan. In the pool-type SFR, the primary system piping connects primary pump and the high-pressure sodium plenum located at the inlet of fuel sub-assemblies and called "pump/diagrid link". Because this piping is submerged in the reactor vessel, it is difficult to detect small scale sodium leakage in this piping, and thus a certain large pipe break like guillotine should be assumed and evaluated as a design basis event. In order to confirm the detectability of pump/diagrid link rupture by safety protection system signals, a series of analyses of the guillotine break for a pump/diagrid link were carried out. Sensitivity study had also been performed to consider the uncertainty of the reactivity coefficient in the analyses. The sufficiency of the function of the plant protection system against the pump/diagrid link rupture was confirmed by the analysis results that at least two signals are transmitted for the detection of the event, which is the development target of the plant protection system in pool-type SFR.

Journal Articles

Validation of core cooling capability analysis in Monju during guillotine pipe break at primary heat transport system

Yamada, Fumiaki; Arikawa, Mitsuhiro*; Fukano, Yoshitaka

Proceedings of 23rd International Conference on Nuclear Engineering (ICONE-23) (DVD-ROM), 7 Pages, 2015/05

In sodium-cooled fast reactor, since the coolant does not need to be pressurized, a pipe break due to the internal pressure does not occur physically. For safety margin in Japanese prototype fast breeder reactor (Monju), the guillotine pipe break accident, i.e., loss of integrity (LOPI) has been analyzed as an extreme assumption for beyond design basis accidents (B-DBAs) in the licensing application for the permit. The cooling capability of the core was re-evaluated in this paper during a large-scale, more specifically guillotine pipe break at the primary heat transport system (PHTS) in Monju, newly considering the following latest findings: (a) Experimental data on sodium boiling in fuel assemblies, (b) Actual PHTS pump coast-down characteristics, and (c) Transient burst test data on irradiated fuel claddings. The analysis models were the validated and simulations were re-performed also using the actual Monju data such as the response time to the trip signals, etc. As a result, it was clarified that the ratio of failed fuel claddings does not exceed around 3% of all of fuel assemblies, as in the past licensing analysis. The safety has been reconfirmed to be secured without significant core damage even under an extreme assumption of a double-ended guillotine pipe break at the PHTS in Monju.

JAEA Reports

3 (Records 1-3 displayed on this page)
  • 1