検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 4 件中 1件目~4件目を表示
  • 1

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

発表言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Current status of development in the 3D seismic isolation applied to SFRs

山本 智彦; 渡壁 智祥; 宮崎 真之; 岡村 茂樹; 宮川 高行; 横井 忍*; 深沢 剛司*; 藤田 聡*

Mechanical Engineering Journal (Internet), 11(2), p.23-00393_1 - 23-00393_21, 2024/04

A sodium-cooled fast reactor (SFR) considers adopting 3-dimensional seismic isolation devices for withstanding seismic loads not only horizontal but also vertical direction. A seismic isolation device consists of a laminated rubber bearing and horizontal oil dampers for horizontal direction, coned disc springs and vertical oil dampers for vertical direction, respectively. In order to investigate the performance of each component and the feasibility of integrated system for SFR, the experiments such as load-displacement tests, vibrating tests, etc., to each component of seismic isolation devices and seismic response analysis are carried out. As those experimental results, the mechanical characteristics of each component and the devices are grasped, then it is demonstrated that components and devices have expected performances to reduce the seismic loading within the design range. As the analytical results of seismic response, it is indicated that this 3-dimesional seismic isolation device and system can reduce the seismic response on horizontal and vertical simultaneously. Based on the analytical studies and experimental results, the feasibility of newly developed 3-dimensional seismic isolation system is obtained and the prospect of practical application of 3D seismic isolation system for fast reactor is implied in this paper.

論文

Status of development in the 3D seismic isolation applied to SFRS

山本 智彦; 渡壁 智祥; 宮崎 真之; 宮川 高行*; 横井 忍*; 岡村 茂樹*; 深沢 剛司*; 藤田 聡*

Proceedings of 30th International Conference on Nuclear Engineering (ICONE30) (Internet), 7 Pages, 2023/05

A sodium-cooled fast reactor (SFR) considers adopting 3-dimensional seismic isolation devices for withstanding seismic loads not only horizontal but also vertical direction. In order to investigate the performance of each component and the feasibility of integrated system for SFR, the experiments to each component of seismic isolation devices and seismic response analysis are carried out. As those experimental results, the mechanical characteristics of each component and the devices are grasped. As the analytical results of seismic response, it is indicated that this 3-dimesional seismic isolation device and system can reduce the seismic response on horizontal and vertical simultaneously. Based on the analytical studies and experimental results, the feasibility of newly developed 3-dimensional seismic isolation system is obtained and the prospect of practical application of 3D seismic isolation system for fast reactor is implied in this paper.

論文

Status on seismic design and verification for ITER in Japan

武田 信和; 中平 昌隆; 多田 栄介; 藤田 聡*; 藤田 隆史*

日本地震工学会論文集(インターネット), 4(3), p.298 - 304, 2004/04

ITERはトカマク型の国際核融合実験装置であり、主要機器は、超伝導コイル,真空容器等で、運転温度は4Kから200$$^{circ}$$Cまでと幅広い。このため、主要機器の支持構造はトーラス構造の半径方向に柔軟,鉛直方向に剛となるよう、多層板バネ構造を採用している。この結果トカマク装置の水平方向固有振動数は4Hzと低く、さらに地震に対しては国際標準のIAEAに照らし、地表加速度0.2gで標準設計しており、これを超える地震を想定する場合は免震が必要となる。これらの特殊事情により、ITERの動的特性を把握するための解析,実験を日本で実施している。動解析では、日本のサイト及び免震を考慮した地震動により装置の健全性を確認した。この裏付けデータ取得のため、縮小モデルの振動試験体の製作を開始した。最初の試験として、コイル単体及び支持脚単体の固有振動数及び剛性データを取得した。本論文では、ITER主要機器の動特性を把握する日本の解析及び実験の現状と計画を述べる。

論文

Development of probabilistic methodology for evaluating seismic base isolation of nuclear components and verification test program

柴田 勝之; 蛯沢 勝三; 安藤 和博*

Proc. of 7th German-Japan Joint Seminar on Research in Structural Strength and NDE-Problems, 12 Pages, 1997/00

機器免震は、安全上重要な個々の機器の耐震性とプラントの安全性を向上できる技術として有望視されるが、いまだ実用化されていない。機器免震の特徴は、既存プラントの機器への適用性が高く、経済性にも優れていることである。本研究では、軽水炉機器の耐震性と地震リスクの低減に資するため、機器免震の評価手法開発と関連試験を進めている。Phase Iの研究として、機器免震効果を確率論的手法により評価するEBISA(Equipment Base Isolation System Analysis)コードを開発した。また、免震装置の設計法の検討等も行った。さらに、安全上の重要機器として起動変圧器を免震構造化した場合の損傷 度の低減効果について感度解析を行った。Phase IIとして、コードの検証と高度化をめざした機器免震実験を8年度に開始した。本報告では、これまでの成果と今後の研究計画について概要を紹介する。

4 件中 1件目~4件目を表示