Okamoto, Naritoshi; Komeno, Akira; Seya, Atsumasa; Inaba, Hideki*; Terakado, Shinichi*; Higuchi, Masashi*
JAEA-Data/Code 2025-022, 497 Pages, 2026/03
The Plutonium Fuel Third Development Laboratory of the Nuclear Fuel Cycle Engineering Laboratories has applied for a change of use permit (hereinafter referred to as "license") for plutonium fuel facilities. For the criticality safety design of gloveboxes and equipment/instruments handling mixed oxide (MOX), various criticality calculation codes are used. The most recent employs the 3D Monte Carlo calculation code KENO-V.a embedded in the SCALE 4.4 code system, along with the 27-group ENDF/B-IV neutron cross-section library. SCALE 4.4 was released by the Oak Ridge National Laboratory (ORNL) in the US in 1998, and has now been in use for 27 years. ORNL has continuously improved its functionality, with SCALE 6.3.2 released in 2024. When designing and constructing new MOX fuel facilities, it is desirable to obtain a license using criticality calculation codes based on the latest knowledge. However, it is necessary to verify that these codes have sufficient reliability. Therefore, in 2018, benchmark calculations were performed using the 252-group ENDF/B-VII.1 neutron cross-section library (v7-252n) for two versions of the criticality calculation sequences KENO-V.a and KENO-VI from SCALE 6.2.3, based on past criticality experimental setups. The estimated critical-limiting multiplication factor was calculated. The results indicate that these codes can be used with sufficient confidence for criticality safety design of MOX fuel facilities.
Tamaki, Hitoshi; Hamaguchi, Yoshikane; Yoshida, Kazuo; Muramatsu, Ken
Proceedings of International Conference on Nuclear Energy System for Future Generation and Global Sustainability (GLOBAL 2005) (CD-ROM), 6 Pages, 2005/10
A PSA procedure for MOX fuel fabrication facilities is being developed at the JAERI. This procedure consists of four steps, which are hazard analysis, accident scenario analysis, frequency evaluation and consequence evaluation. The proposed procedure is characterized by the hazard analysis step. The Hazard analysis step consists of two sub-steps. In the first sub-step, a variety of functions of equipment composing the facility are analyzed to identify potential abnormal events exhaustively. In the second sub-step, these potential events are screened to select abnormal events by using a risk matrix based on the rough estimation of likelihood and maximum unmitigated release of radioactive material. One of the unique technical issues in this research is the estimation of likelihood of criticality event. A method is also proposed as a part of PSA procedure taking into consideration of failure of a computerized control system for MOX powder handling process. The applicability of the PSA procedure was demonstrated through the trial application of it to a model plant of MOX fuel fabrication facility.
Tashiro, Shinsuke; Abe, Hitoshi; Morita, Yasuji
JAERI-Conf 2005-007, p.348 - 350, 2005/08
Hot test at Rokkasho Reprocessing plant has been started since last year. In addition, construction of the MOX fuel fabrication facility at Rokkasho site is planning. So, the importance of safety evaluation of the nuclear fuel cycle facility is increasing. Under the fire accident, one of the serious postulated accidents in the nuclear fuel cycle facility, the equipments (glove-box, ventilation system, ventilation filters etc.) for the confinement of the radioactive materials within the facility could be damaged by a large amount of heat and smoke released from the combustion source. Therefore, the fundamental data and models calculating for the amount of heat and smoke released from the combustion source under such accident are important for the safety evaluation of the facility. In JAERI, the study focused on the evaluation of amount of heat and smoke released from the combustion source is planning. In this paper, the outline of experimental apparatus, measurement items and evaluation terms are described.
Tamaki, Hitoshi; Yoshida, Kazuo; Watanabe, Norio; Muramatsu, Ken
Proceedings of International Topical Meeting on Probabilistic Safety Analysis (PSA '05) (CD-ROM), 11 Pages, 2005/00
A probabilistic safety assessment (PSA) procedure for Mixed Oxide (MOX) fuel fabrication facilities is being developed applicable to nuclear facilities at Japan Atomic Energy Research Institute (JAERI). As part of the PSA procedure, the approach to hazard analysis was established, which consists of two analysis steps: Functional Failure Modes and Effects Analysis (Functional FMEA) and Risk Matrix Analysis. In the Functional FMEA, a variety of functions of equipment composing the facility are analyzed to identify potential abnormal events exhaustively. In the second step, these potential events are screened to select abnormal events as candidate events to be analyzed for frequency and consequence by using two-dimensional matrix based on the rough estimation of likelihood and maximum unmitigated release of radioactive material. The applicability of the hazard analysis approach established was demonstrated through the trial application of the PSA procedure being developed to model plant of MOX fuel fabrication facility.