Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Abe, Satoshi; Studer, E.*; Ishigaki, Masahiro; Shibamoto, Yasuteru; Yonomoto, Taisuke
Nuclear Engineering and Design, 368, p.110785_1 - 110785_14, 2020/11
Times Cited Count:14 Percentile:82.90(Nuclear Science & Technology)Ito, Chikara; Naito, Hiroyuki; Ishikawa, Takashi; Ito, Keisuke; Wakaida, Ikuo
JPS Conference Proceedings (Internet), 24, p.011038_1 - 011038_6, 2019/01
A high-radiation resistant optical fiber has been developed in order to investigate the interiors of the reactor pressure vessels and the primary containment vessels at the Fukushima Daiichi Nuclear Power Station. The tentative dose rate in the reactor pressure vessels is assumed to be up to 1 kGy/h. We developed a radiation resistant optical fiber consisting of a 1000 ppm hydroxyl doped pure silica core and 4 % fluorine doped pure silica cladding. We attempted to apply the optical fiber to remote imaging technique by means of fiberscope. The number of core image fibers was increased from 2000 to 22000 for practical use. The transmissive rate of infrared images was not affected after irradiation of 1 MGy. No change in the spatial resolution of the view scope by means of image fiber was noted between pre- and post-irradiation. We confirmed the applicability of the probing system, which consists of a view scope using radiation-resistant optical fibers.
Ichikawa, Shoichi; Chiba, Yusuke; Ono, Fumiyasu; Hatori, Masakazu; Kobayashi, Takanori; Uekura, Ryoichi; Hashiri, Nobuo*; Inuzuka, Taisuke*; Kitano, Hiroshi*; Abe, Hisashi*
JAEA-Research 2017-001, 40 Pages, 2017/03
In order to reduce the influence on a plant schedule of the MONJU by the maintenance of dew point hygrometers, The JAEA examined a capacitance type dew point hygrometer as an alternative dew point hygrometer for a lithium-chloride type dew point hygrometer which had been used at the CV-LRT in the MONJU. As a result of comparing a capacitance type dew point hygrometer with a lithium-chloride type dew point hygrometer at the CV-LRT (Atmosphere: nitrogen, Testing time: 24 hours), there weren't significant difference between a capacitance type dew point hygrometer and a lithium-chloride type dew point hygrometer. As a result of comparing a capacitance dew point hygrometer with a high-mirror-surface type dew point hygrometer for long term verification (Atmosphere: air, Testing time: 24 months), the JAEA confirmed that a capacitance type dew point hygrometer satisfied the instrument specification (2.04C) required by the JEAC4203-2008.
;
Journal of Nuclear Science and Technology, 31(6), p.510 - 520, 1994/06
Times Cited Count:18 Percentile:79.67(Nuclear Science & Technology)no abstracts in English
Okumura, Keisuke; Riyana, E. S.
no journal, ,
We have predicted the dose rate distribution inside PCV of Unit 1 and Unit 2 in 2021 by combination of Monte Carlo calculation with local dose rates measurements obtained so far by the internal investigations of the Fukushima Daiichi Nuclear Power Station.