Takamatsu, Kuniyoshi; Nakagawa, Shigeaki
JAERI-Data/Code 2005-003, 31 Pages, 2005/06
Safety demonstration tests using the High Temperature engineering Test Reactor (HTTR) are in progress to verify the inherent safety features for High Temperature Gas-cooled Reactors (HTGRs). The coolant flow reduction test by tripping gas circulators is one of the safety demonstration tests. The reactor power safely brings to a stable level without a reactor scram and the temperature transient of the reactor-core is very slow. The TAC/BLOOST code was developed to analyze reactor and temperature transient during the coolant flow reduction test taking account of reactor dynamics. This paper describes the validation result of the TAC/BLOOST code with the measured values of gas circulators tripping tests at 30 % (9 MW). It was confirmed that the TAC/BLOOST code was able to analyze the reactor transient during the test.