Heat transfer coefficient modeling for downward saturated boiling flows in vertical pipes

和田 裕貴; 柴本 泰照; 日引 俊詞*

International Journal of Heat and Mass Transfer, 249, p.127219_1 - 127219_16, 2025/10

Two saturated boiling heat transfer correlations for downward flows in vertical circular pipes depending on wall superheat or wall heat flux as input parameters were developed based on a heat transfer experimental database. Owing to the absence of heat transfer correlations specifically developed for downward flows, existing heat transfer correlations for different flow directions were evaluated to determine their applicability to predicting the downward flow heat transfer coefficient. The results revealed that even the most accurate correlation showed a mean absolute percentage error (MAPE) of 66.5%, highlighting the need for improving predictive performance. In response, the downward flow heat transfer correlation was modeled by integrating a nucleate boiling heat transfer term and a forced convection heat transfer term. The Dong-Hibiki correlation, a two-component, two-phase heat transfer correlation for downward flows, was adopted for the forced convection heat transfer term. The Forster-Zuber correlation, developed as a wall superheat function, and the Cooper correlation, developed as a wall heat flux function, were used for the nucleate boiling term to develop the heat transfer correlations where either wall superheat or wall heat flux is known. Notably, the Dong-Hibiki correlation has been validated over a wide range of experimental conditions. A correction factor was applied to the nucleate boiling term to address errors caused by applying Foster-Zuber and Cooper correlations to downward flows. The two developed correlations achieved an MAPE value of approximately 20%, representing an improvement of roughly 40% over existing correlations of heat transfer coefficients.

論文

Heat transfer characteristics of downward saturated boiling flow in vertical round pipes

和田 裕貴; 柴本 泰照; 日引 俊*

International Journal of Heat and Mass Transfer, 239, p.126598_1 - 126598_18, 2025/04

 被引用回数:1 パーセンタイル:27.01(Thermodynamics)

This study reviewed the saturated boiling heat transfer research in downward flows. A database of downward flow heat transfer experiments was created using experimental studies. Saturated boiling heat transfer correlations in internal flows were collected, and no downward flow-specific heat transfer correlations were identified. The applicability of heat transfer correlations to downward flow heat transfer experiments was evaluated, and no correlation could predict the heat transfer coefficients accurately for all experimental databases. However, correlations that could predict heat transfer coefficients reasonably well were determined for each channel size. Cooper's correlation [Int. Chem. Eng. Symp. Ser. 86 (1984) 785-792] had a mean absolute percentage error (MAPE) of 11.7% for mini-channels and Kim and Mudawar's correlation [Int. J. Heat Mass Transf. 64 (2013) 1239-1256] had an MAPE of 66.5% for macro-channels. Furthermore, because the advection direction between the liquid-phase and the generated bubbles differed depending on the liquid-phase velocity in downward flows, we evaluated the prediction performance of the heat transfer coefficient for the liquid-phase velocity. For some experimental data, the prediction performance of the existing correlation for downward flow heat transfer worsened as the advection velocity of the bubbles decreased. This result is one of the issues to be addressed in the future development of heat transfer correlations.

論文

放射光X線と中性子を相補的に用いた小口径突合せ溶接配管の実応力解析

鈴木 賢治*; 三浦 靖史*; 城 鮎美*; 豊川 秀訓*; 佐治 超爾*; 菖蒲 敬久; 諸岡 聡

材料, 72(4), p.316 - 323, 2023/04

Residual stresses in small-bore butt-welded pipe of austenitic stainless steel have never been measured. It is difficult to obtain a detailed residual stress map of the root welded part, because the gauge volume in neutron diffraction is large. The stress evaluation of the welded part by synchrotron X-rays was also difficult due to the dendritic structure. In this study, a double exposure method (DEM) with high-energy synchrotron X-rays was applied to measuring the details of the residual stress of the welded part, and we succeeded in obtaining the detailed axial and radius stress maps of the root welded part of the plate cut from the welded pipe, though the stress map was under the plane stress condition. The hoop stress map of the butt-welded pipe was obtained using the strain scanning method with neutrons under the triaxial stress state. The axial and radius stress maps under triaxial stress state were made up using the complementary use of the synchrotron X-ray and neutron. As a result, the detailed stress maps of the root welded part of the butt-welded pipe were obtained. The obtained map sufficiently explained the initiation and propagation of SCC.

報告書

Flow separation at inlet causing transition and intermittency in circular pipe flow

小川 益郎*

JAEA-Technology 2019-010, 22 Pages, 2019/07

JAEA-Technology-2019-010.pdf:1.5MB

円管内流れは、流れが実際に遷移し、遷移流が間欠性を示すにもかかわらず、あらゆる小さな外乱に対して線形的に安定である。このことは、流体力学ではまだ解決されていない大きな課題の一つである。そこで、著者は、これまで誰も気がつかず認識してこなかった事実を初めて指摘する。この事実というのは、「円管内の流れは、流れの剥離によって、円管入り口付近に形成される剥離泡から放出された渦のために層流から遷移し、そして渦放出が間欠的であるために遷移流が間欠性を示す。」というものである。この事実は、円管の入口形状が遷移レイノルズ数に大きく影響することや、第3の遷移現象に分類されている外側円筒が支配的に回転する同心二重円筒間の流れが円管内の遷移流れと同様に流れの剥離によって間欠性を示すといった、多くの実験結果によって裏付けられている。本研究によって、高温ガス冷却炉の熱流体設計において最も重要な課題の一つである熱伝達促進のために、急縮小型の入口形状が遷移開始レイノルズ数をできる限り小さくできることを明らかにした。

論文

Development of laser instrumentation devices for inner wall of high temperature piping system

西村 昭彦; 古澤 彰憲; 竹仲 佑介*

AIP Conference Proceedings 2033, p.080002_1 - 080002_5, 2018/11

 被引用回数:1 パーセンタイル:49.29(Green & Sustainable Science & Technology)

伝熱管内壁の検査補修技術として光ファイバイメージスコープとレーザー溶接技術を組み合わせた保守保全装置の開発を行ってきた。ファイバスコープによる観察、レーザー肉盛り加工補修、コノプローブ計測など主要な技術について報告する。本技術は高速炉配管への適用を計画している。本会議では、高速炉2次系配管と構造的に共通要素が多い太陽熱発電プラントへの適用を提案する。本技術は、高繰り返し熱負荷と溶融塩腐食にさらされる太陽熱発電プラントの保守保全に有用である。

論文

Demonstration of $$gamma$$-ray pipe-monitoring capabilities for real-time process monitoring safeguards applications in reprocessing facilities

Rodriguez, D.; 谷川 聖史; 西村 和明; 向 泰宣; 中村 仁宣; 栗田 勉; 高峰 潤; 鈴木 敏*; 関根 恵; Rossi, F.; et al.

Journal of Nuclear Science and Technology, 55(7), p.792 - 804, 2018/07

 被引用回数:0 パーセンタイル:0.00(Nuclear Science & Technology)

再処理施設の核物質に対しては、ランダムサンプル検認と、追加的な重要タンク内溶液の体積、質量のみの連続監視システムによる"知識の連続性"保持により、保障措置が掛けられている。核物質溶液がタンク及び工程装置を結ぶ配管を流れる際に、特徴的な$$gamma$$を測定し、核物質を実時間で検認することで、工程監視を改善できる可能性がある。われわれは、東海再処理工場の転換技術開発施設で、この$$gamma$$パイプモニタリングを、硝酸Pu移送の際に試した。この際$$gamma$$測定は、ランタン・ブロマイド検出器、及び$$gamma$$の計数時刻とエネルギーを記録するリストモード・データ取得システムを用いて実施した。この測定結果とその分析は、配管内溶液の同位体組成、工程移動時刻、(単位時間当たりの)溶液流量及び移動溶液量を求められる能力を実証するものであり、実際に適用可能な保障措置検認工程監視の導入に繋がる。

論文

福井県における原子力機構によるレーザー研究開発と産業振興

古澤 彰憲; 竹仲 佑介*; 西村 昭彦; 水谷 春樹; 村松 壽晴

日本保全学会第14回学術講演会要旨集, p.479 - 480, 2017/08

本報告では、原子力機構福井支部における、レーザー応用研究と産業振興について述べる。産業振興はプラント保全保守技術の発展および廃炉技術の確立のため不可避であり、長期的な視点をもって戦略的に取り組むべき課題である。原子力機構福井支部ではその視点に基づいてこれまでに、産業振興と産業界との技術交流を促進する公開セミナー活動を行ってきた。ここでは平成29年度における同セミナーで紹介した課題のうち特にレーザー応用研究開発に関するものの紹介を行い、最後に我々の目指すところと重要な視点について述べる。

論文

$$gamma$$-ray pipe monitoring for comprehensive safeguards process monitoring of reprocessing facilities

Rodriguez, D.; 谷川 聖史; 向 泰宣; 磯前 日出海; 中村 仁宣; Rossi, F.; 小泉 光生; 瀬谷 道夫

Proceedings of INMM 58th Annual Meeting (Internet), 9 Pages, 2017/07

再処理施設の核物質の保障措置においては、定量検認のためのサンプリングと再検認を減らすために、知識の連続性(CoK)保持のためのプロセスモニタリングが使われている。現在タンクに設置されているSMMSは、溶液の体積と密度情報を提供するのみであり、間接的な監視(検認)がなされている。この限界を埋め合わせるために、我々は、配管内を流れる溶液及びタンク内の溶液からの$$gamma$$線を測定する、連続かつ直接的な検認を行う、改善された方法を提案する。この方法では、実時間で溶液流れの確認、Pu同位体の確認が非破壊で得られるものである。この概念については、原子力機構のPCDFにて配管内を流れる硝酸プルトニウムからの$$gamma$$線を測定する試験が行われた。この発表は、$$gamma$$線パイプモニタリングを使う概念と分析が、実時間の保障措置検認能力を有することについて述べるものである。

論文

Multi-dimensional gas-liquid two-phase flow in vertical large-diameter channels

Shen, X.*; Schlegel, J. P.*; 日引 俊*; 中村 秀夫

Proceedings of 2017 Japan-US Seminar on Two-Phase Flow Dynamics (JUS 2017), 6 Pages, 2017/06

Large-diameter (D) channels are extensively used to increase the mass, momentum and heat transport capability of working fluid. Comparing with small-D pipes, two-phase flows in large-D channels show quite different and more complicated flow characteristics, since much larger cap bubbles can exist and interfacial instability prevents the cap bubbles from forming a large stable Taylor bubble. Flow regimes and radial void fraction profiles are also different from those in small-D pipes especially in cap/slug flow regime. The relative velocities between phases are greatly increased. This paper reviews recent progresses in the researches on two-phase flows in large-D channels. The state-of-the-art tool of four-sensor probe may enable classification of two-group bubbles by the measurement of bubble diameter instead of bubble chord length. Databases and most of the updated constitutive equations that cover flow regime transition criteria, drift-flux correlations, interfacial area concentration (IAC) correlations and one- and two-group interfacial area transport equation(s) are summarized and analyzed. Typical multi-dimensional characteristics of flows in large-D channels are presented and their one-dimensional numerical simulations are reviewed. Finally the future research directions are suggested.

論文

Validation of core cooling capability analysis in Monju during guillotine pipe break at primary heat transport system

山田 文昭; 有川 晃弘*; 深野 義隆

Proceedings of 23rd International Conference on Nuclear Engineering (ICONE-23) (DVD-ROM), 7 Pages, 2015/05

ナトリウム冷却高速炉において低圧である冷却材配管のギロチン破断は物理的に生じないが、高速増殖原型炉もんじゅでは安全評価の一つとして、ギロチン破断を念のために仮想的に設定し、許認可のための評価を行ってきた。本論文では、もんじゅ1次主冷却系配管大口径破損時の炉心冷却能力評価において、評価結果に影響を及ぼす現象について、以下のこれまでの試験データの蓄積を踏まえ、解析評価の妥当性を検証した。(a)炉心流量低下に伴い生じる炉心ナトリウム沸騰に関する試験データ、(b)1次主冷却系循環ポンプトリップ後のフローコーストダウンのもんじゅデータ、(c)燃料被覆管の破損評価に用いるLMP回帰曲線の照射済み燃料被覆管急速加熱バースト試験データ、さらに、原子炉トリップ信号応答時間等のもんじゅ実機データも適用し、炉心冷却能力を最新評価した。その結果、燃料被覆管の破損率は従来評価を上回ることなく、あえて1次主冷却系配管にギロチン破断を仮定したとしても、炉心の大規模な損傷に至らないことを評価した。

論文

Experience of HTTR construction and operation; Unexpected incidents

藤本 望; 橘 幸男; 七種 明雄*; 篠崎 正幸; 磯崎 実; 伊与久 達夫

Nuclear Engineering and Design, 233(1-3), p.273 - 281, 2004/10

 被引用回数:0 パーセンタイル:0.00(Nuclear Science & Technology)

HTTRの出力上昇試験では、熱漏洩の観点から二つの事象があった。一つは一次上部遮蔽体の温度上昇であり、もう一つは炉心支持板の温度上昇であった。これら二つの原因は構造物中のわずかなヘリウムの流れによるものであった。一次上部遮蔽体の温度上昇については、微少なヘリウム流れの抑制,放熱の促進,断熱材の設置が行われた。炉心支持板の温度上昇については、微少なヘリウム流れを考慮した温度評価を再度行い、炉心支持板の設計温度を見直した。これらの対策により、それぞれの温度を制限値以下に収めることができた。

論文

Dry flowing abrasive decontamination technique for pipe systems with swirling air flow

亀尾 裕; 中島 幹雄; 平林 孝圀*

Nuclear Technology, 144(1), p.76 - 82, 2003/10

 被引用回数:2 パーセンタイル:18.49(Nuclear Science & Technology)

原子炉施設の解体前除染技術として、アルミナ又は鋳鉄グリット研磨材と空気の旋回流を利用した乾式除染技術について検討した。旋回流によるステンレス及び炭素鋼配管の研削挙動を調べた結果、配管内表面の研削深さは空気流速の累乗及び研磨材濃度に比例して増加することがわかった。除染条件を最適化した後、動力試験炉(JPDR)の原子炉水浄化系統から切り出した汚染配管に対する除染試験を行った。これらの試験から、本技術が原子炉施設の廃止措置における解体前除染技術として有効であることが明らかになった。

報告書

JMTR計測用配管のき裂発生原因の調査報告書; 配管部の振動解析と応力解析の結果

塙 悟史; 橘 幸男; 伊与久 達夫; 石原 正博; 伊藤 治彦

JAERI-Tech 2003-064, 25 Pages, 2003/07

JAERI-Tech-2003-064.pdf:2.84MB

材料試験炉(JMTR:Japan Materials Testing Reactor)は、第147サイクルの共同利用運転中に、一次冷却系統の精製系統充填ポンプNo.1の出口配管に取り付けられた圧力計導管からの水漏れが確認されたため、12月10日に原子炉を手動停止した。当該圧力計導管については、充填ポンプが加振源となり圧力計導管が振動し、その繰り返し荷重によりき裂が発生・進展した可能性がある。このため、当該部の振動解析と応力解析を実施した。振動解析の結果、充填ポンプNo.1圧力計導管の固有振動数は53$$sim$$58Hz程度と推定され、共振周波数である50Hz(充填ポンプ回転数)に近い状態にあった。応力解析の結果、振動により当該圧力計導管に発生する応力は固有振動数53Hzで63MPa,58Hzで25MPaと求められた。振動による応力と、自重と内圧による応力の合計値を計算すると、固有振動数53Hzで112.2MPa,58Hzで74.2MPaになる。これらの発生応力は使用材料の疲れ限度に近い値であり、充填ポンプNo.1の圧力計導管に生じたき裂は、充填ポンプの振動に起因する疲労によるものと推測された。

報告書

JMTR計測用配管のき裂発生原因の調査報告書; JMTRホットラボにおける圧力計導管の検査に関するデータ集

き裂発生原因の調査ワーキンググループ

JAERI-Tech 2003-060, 183 Pages, 2003/07

JAERI-Tech-2003-060.pdf:55.37MB

日本原子力研究所大洗研究所の材料試験炉(JMTR)において、平成14年12月10日に一次冷却系統の精製系統充填ポンプNo.1の出口配管に取り付けられた圧力計導管に水漏れが確認された。また、水漏れ停止後に行った外観観察及び浸透探傷試験の結果、当該圧力計導管にき裂が確認された。このため、水漏れ発生の原因と対策及び安全管理への取組みについて検討するために、日本原子力研究所内外の専門家から構成する「JMTR計測用配管水漏れ調査検討委員会」が平成14年12月16日に設置された。これを受けて、当該圧力計導管におけるき裂発生の原因を調査するためのワーキンググループを材料試験炉部に設置し、圧力計導管とその溶接部分を含む試料を切り出し、ホットラボ施設において外観検査,破面観察,金属組織観察,硬さ測定等を実施した。本報告書は、これらのデータをまとめたものである。

論文

Indirect air cooling techniques for control rod drives in the high temperature engineering test reactor

竹田 武司; 橘 幸男

Nuclear Engineering and Design, 223(1), p.25 - 40, 2003/07

 被引用回数:2 パーセンタイル:18.49(Nuclear Science & Technology)

HTTR(高温工学試験研究炉)の16対の制御棒は反応度変化を制御するため用いられる。HTTRは日本初の高温ガス炉であり、原子炉出口ガス温度は950$$^{circ}$$C,熱出力は30MWである。原子炉圧力容器の上部に取り付けられている制御棒用スタンドパイプには、制御棒駆動装置が1個ずつ収納されている。制御棒駆動装置の温度が180$$^{circ}$$Cを越える場合、電磁クラッチの電気絶縁性が低下し、制御棒駆動装置が正常に機能しない恐れがある。31本のスタンドパイプはスタンドパイプ室に林立しており、中央にある制御棒用スタンドパイプを効果的に冷却すべきである。そこで、適切な空気吹出しノズルと空気吸込口を有する1対のリング状ダクトを介して、空気の強制循環により制御棒駆動部を間接的に冷却することとした。解析結果に基づくリング状ダクトをスタンドパイプ室に据え付けた。HTTRの出力上昇試験の評価結果から、全出力運転及びスクラム時において、制御棒用スタンドパイプ内の電磁クラッチ及びその回りのヘリウムガス雰囲気温度はそれぞれ180$$^{circ}$$C,75$$^{circ}$$Cを下回ることが明らかになった。

報告書

JMTR計測用配管水漏れ調査報告書

JMTR計測用配管水漏れ調査検討委員会

JAERI-Review 2003-014, 117 Pages, 2003/03

JAERI-Review-2003-014.pdf:27.62MB

日本原子力研究所大洗研究所材料試験炉(JMTR)において、平成14年12月6日に、漏水検知器の警報が発報し、平成14年12月10日、一次冷却系統の精製系統充填ポンプNo.1の出口配管に取り付けられた圧力計導管に水漏れが確認された。日本原子力研究所では、所内外の専門家から構成する「JMTR計測用配管水漏れ調査検討委員会」を平成14年12月16日に設置して、平成15年1月6日までに公開による委員会を3回開催し、水漏れ発生の原因と対策及び安全管理への取組みについて検討を行った。本報告書は水漏れ発生の原因と対策及び安全管理への取組みについて取りまとめたものである。

報告書

D-T中性子照射による核融合炉材料中での逐次反応に関する実験的研究

堀 順一; 佐藤 聡; 山内 通則*; 落合 謙太郎; 西谷 健夫

JAERI-Research 2003-002, 50 Pages, 2003/03

JAERI-Research-2003-002.pdf:2.21MB

本研究では、低放射化フェライト鋼(F82H)と酸化物分散強化型(ODS)フェライト鋼に対してD-T中性子照射を行い、逐次反応による$$^{56}$$Co生成実効断面積を測定した。F82H,ODSフェライト鋼に対する$$^{56}$$Co生成実効断面積は、鉄の約1.5倍となった。さらに、6種類の核融合炉材料(鉄,銅,バナジウム,チタン,タングステン,鉛)とF82Hに対して、水素化合物との接触面領域での逐次反応実効断面積の分布を測定した。水素化合物との接触面で逐次反応率は同一材料の場合と比べて20倍以上となり、F82Hに対しては50倍となった。核融合冷却水配管表面で生成される$$^{56}$$Coによる放射能は、1次中性子反応で生成される$$^{54}$$Mnによる放射能の3~10%に至ることを示した。逐次反応実効断面積を(n,xp), (p,n)反応断面積,陽子放出スペクトル,陽子阻止能を用いて評価し、実験値との比較を行なった。

論文

ITERの遠隔保守技術

角舘 聡; 柴沼 清

検査技術, 7(11), p.28 - 33, 2002/11

ITERは核融合反応時に発生する中性子により容器内構造物は放射化される。このため、ITER容器内構造物の保守が必要な場合には、ロボットによる遠隔保守が必要となる。ここでは、ITERの遠隔保守ロボット技術の代表例として、ブランケット保守用ロボットと冷却配管用溶接・切断・検査用ロボットについて述べる。ブランケット保守では、真空容器の回りから4点で支持されたリング状レールに沿って移動可能なロボットにより、ブランケットの保守を行うビークル型ロボットシステムを考案した。ブランケット保守の課題は、(1)駆動源を持たない単純構造レールの真空容器内への展開方法,(2)4tの大重量ブランケットを$$pm$$2mm以内の高精度で位置あわせ可能なセンサー・フィードバック制御方法,(3)4tのブランケットの取り付け・取り外し時における急負荷・急除荷時における衝撃抑制方法である。これらの課題は、新たに開発した制御法等を実規模ロボットに適用し実証試験を行うことにより解決した。また、配管の溶接・切断では、曲がり管にも対応可能な光ファイバーをレーザービームの伝送系に採用し、しかも同一のロボットで溶接と切断が可能なYAGレーザーを用いた冷却配管の溶接・切断ロボットを開発した。本ロボットにより、母管外径100mm(曲げ半径400mm)で板厚6mm,枝管外径60mmで板厚3mmの溶接・切断試験を行った結果、良好な結果を得ることができ、配管用溶接・切断ロボットの成立性を実証した。

報告書

浜岡原子力発電所1号機配管破断部サンプル調査適用試験

ホット試験室

JAERI-Tech 2002-050, 51 Pages, 2002/06

JAERI-Tech-2002-050.pdf:18.17MB

平成13年11月7日、中部電力浜岡原子力発電所1号機で、非常用炉心冷却系(ECCS)の高圧注入系(HPCI)で手動起動試験開始直後、余熱除去系(蒸気系)の配管が破断し、蒸気漏れ事故が発生した。この事故の原因究明に向けて、急きょ、経済産業省原子力安全・保安院(保安院)では、タスクフォースを設置し配管破断部を切断して詳細調査を行うこととし、事業者(中部電力)による調査と並行して第三者中立機関である日本原子力研究所(原研)に対して調査協力の指示を文部科学省に依頼した。これを受けて、原研東海研究所では浜岡1号機配管破断部調査グループを設置して、配管破断部から採取した試料(調査試料)の調査を東海研燃料試験施設等の各種装置類を用いて行うことになった。本報告書は、ホット試験室の3施設(燃料試験施設,WASTEF,ホットラボ)で実施した全調査試験項目,使用した照射後試験装置,試験技術等の技術的事項について、まとめたものである。

報告書

浜岡原子力発電所1号機余熱除去系配管破断部調査報告データ集

浜岡1号機配管破断部調査グループ

JAERI-Tech 2002-045, 253 Pages, 2002/03

JAERI-Tech-2002-045.pdf:60.08MB

平成13年11月7日に発生した中部電力浜岡原子力発電所1号機余熱除去系配管破断事故の原因究明等を行うため、原子力安全保安院はタスクフォースを設置し配管破断部を切断して詳細調査を行うこととし、事業者(中部電力)による調査と並行して、第三者中立機関である日本原子力研究所に対しての配管破断部調査への協力についての指示を文部科学省に依頼した。原研は、我が国の原子力研究開発の総合的研究機関であるとともに、軽水炉の安全性研究の中核研究機関であること,これまで国内外の原子力施設における事故原因調査等の実績があること,配管破断部調査に必要な試験施設や専門家を有することから、配管破断部調査に全面的に協力することとした。調査にあたって、原研東海研究所に調査グループを設置し、燃料試験施設等の研究施設,走査型電子顕微鏡等の各種分析機器類を活用して、配管破断部の調査を行なった。調査の目的は、配管破断部を切断した部材から採取した試料について、おもに破断面を中心に調査し、配管破断の原因究明に資することである。調査結果については、すでに原子力安全・保安院へ報告するとともに、JAERI-Tech 2001-094として公刊した。本報告書は、この調査で得られたデータの詳細をまとめたものである。

120 件中 1件目~20件目を表示