Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Onoda, Yuichi; Uchita, Masato*; Tokizaki, Minako*; Okazaki, Hitoshi*
Nuclear Technology, 211(11), p.2812 - 2831, 2025/11
Times Cited Count:0 Percentile:0.00(Nuclear Science & Technology)Matsushita, Kentaro; Ezure, Toshiki; Fujisaki, Tatsuya*; Nakamine, Yoshiaki*; Imai, Yasutomo*; Tanaka, Masaaki
Nihon Kikai Gakkai 2025-Nendo Nenji Taikai Koen Rombunshu (Internet), 5 Pages, 2025/09
In the design of sodium-cooled fast reactors (SFRs), it is important to evaluate the transition behavior of non-condensable gas entrained into the primary coolant system due to cover gas entrainment and dissolution. In this study, trajectories of non-condensable gas bubbles in the cold plenum of the pool-type SFR evaluated by three-dimensional CFD analyses applying Discrete Phase Model. As the result of sensitivity analyses regarding bubble radius flowing into the cold plenum, it was clarified that the release rate of bubbles showed an increase according to the increase of bubble radius and an asymptotic increasing behavior in the large bubble radius cases.
Watakabe, Tomoyoshi; Yamano, Hidemasa; Futagami, Satoshi
Transactions of the 28th International Conference on Structural Mechanics in Reactor Technology (SMiRT28) (Internet), 10 Pages, 2025/08
The fragility evaluation method of the RV in the SFR has been developed for both failure mode buckling and fatigue. The past studies showed the fragility using the RV of a loop-type SFR: radius R / thickness t is about 100. Recently, Japan Atomic Energy Agency together with Japanese industrial partners has been conducting a pool-type SFR design. The fragility of the pool-type RV has never been evaluated by the proposed method, which is based on the fatigue failure mode instead of the buckling. To investigate the basic behaviour of the pool-type RV under excessive seismic loading, this report investigated the fragility by using a simple cylindrical model with a wall thickness close to the design of the pool-type RV: R/t is 200, as the first trial.
Nanjo, Kotaro; Shiotsu, Hiroyuki; Maruyama, Yu; Sugiyama, Tomoyuki; Okamoto, Koji*
Journal of Nuclear Science and Technology, 60(7), p.816 - 823, 2023/07
Times Cited Count:1 Percentile:14.77(Nuclear Science & Technology)Zhang, T.*; Morita, Koji*; Liu, X.*; Liu, W.*; Kamiyama, Kenji
Annals of Nuclear Energy, 179, p.109389_1 - 109389_10, 2022/12
Times Cited Count:3 Percentile:32.67(Nuclear Science & Technology)Nanjo, Kotaro; Ishikawa, Jun; Sugiyama, Tomoyuki; Pellegrini, M.*; Okamoto, Koji*
Journal of Nuclear Science and Technology, 59(11), p.1407 - 1416, 2022/11
Times Cited Count:7 Percentile:63.77(Nuclear Science & Technology)Horiguchi, Naoki; Yoshida, Hiroyuki; Kaneko, Akiko*; Abe, Yutaka*
Proceedings of 12th Japan-Korea Symposium on Nuclear Thermal Hydraulics and Safety (NTHAS12) (Internet), 6 Pages, 2022/10
For safety evaluation of nuclear reactors in severe accidents, it is important to estimate physical quantities of fragments generated from the molten fuel jet, which falls in a pool and breaks up. The evaluation method has been developed for the behavior as liquid jet with hydrodynamic interaction including fuel coolant interaction (FCI). In case of a shallow pool assumed in ex-vessel, the molten fuel jet is assumed to behave as wall-impinging liquid jet and to form liquid film flow spreading on the floor with/without fragmentation. In our research, focusing on hydrodynamic interaction and the transient 3-dimensional spreading on the floor, we have developed the evaluation method by numerical simulation using the two-phase flow simulation code with interface tracking method (TPFIT) developed by JAEA and, the experimental method using the 3D-LIF method in liquid-liquid system for the validation data. In our previous studies, we investigated the wall-impinging liquid jet behavior with fragmentation and observed that the liquid film flow had some characteristic parts transiently. Since it indicates that the quantities change depending on the parts and affect the safety evaluation, it is important to measure the quantities of the fragments generated from each part. This paper explains the measurement of the physical quantities of the fragments generated from each part of the wall-impinging liquid jet in a shallow pool for the validation of the numerical simulation. We conducted an experiment with the 3D-LIF method and segmented the experimental data based on the fragmentation point over the liquid film flow using the dispersed phase tracking method, developed by JAEA. Then, we measured the diameter and amount of the fragments from the segmented experimental data and investigated their changing trend.
Onoda, Yuichi; Uchita, Masato*; Tokizaki, Minako*; Okazaki, Hitoshi*
Proceedings of 29th International Conference on Nuclear Engineering (ICONE 29) (Internet), 6 Pages, 2022/08
The safety analyses were carried out to confirm the sufficiency of the function of the plant protection system against the pump/diagrid link rupture. The target plant is a pool-type SFR of about 600 MWe class equipped with an axially homogeneous core currently under development in Japan. In the pool-type SFR, the primary system piping connects primary pump and the high-pressure sodium plenum located at the inlet of fuel sub-assemblies and called "pump/diagrid link". Because this piping is submerged in the reactor vessel, it is difficult to detect small scale sodium leakage in this piping, and thus a certain large pipe break like guillotine should be assumed and evaluated as a design basis event. In order to confirm the detectability of pump/diagrid link rupture by safety protection system signals, a series of analyses of the guillotine break for a pump/diagrid link were carried out. Sensitivity study had also been performed to consider the uncertainty of the reactivity coefficient in the analyses. The sufficiency of the function of the plant protection system against the pump/diagrid link rupture was confirmed by the analysis results that at least two signals are transmitted for the detection of the event, which is the development target of the plant protection system in pool-type SFR.
Horiguchi, Naoki; Yoshida, Hiroyuki; Yamamura, Sota*; Fujiwara, Kota*; Kaneko, Akiko*; Abe, Yutaka*
Proceedings of 19th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-19) (Internet), 14 Pages, 2022/03
Gupta, S.*; Herranz, L. E.*; Lebel, L. S.*; Sonnenkalb, M.*; Pellegrini, M.*; Marchetto, C.*; Maruyama, Yu; Dehbi, A.*; Suckow, D.*; K
rkel
, T.*
Proceedings of 19th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-19) (Internet), 16 Pages, 2022/03
Dehbi, A.*; Cheng, X.*; Liao, Y.*; Okagaki, Yuria; Pellegrini, M.*
Proceedings of 19th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-19) (Internet), 15 Pages, 2022/03
Zhang, T.*; Morita, Koji*; Liu, X.*; Liu, W.*; Kamiyama, Kenji
Extended abstracts of the 2nd Asian Conference on Thermal Sciences (Internet), 2 Pages, 2021/10
For the Japanese sodium cooled fast reactor, a fuel subassembly with an inner duct structure (FAIDUS) was designed to avoid the re-criticality by preventing the large-scale pool formation. In the present study, using the finite volume particle method, the EAGLE ID1 test which was an in-pile test performed to demonstrate the effectiveness of FAIDUS was numerically simulated and the thermal-hydraulic mechanisms underlying the heat transfer process were analyzed.
Miyahara, Shinya*; Kawaguchi, Munemichi; Seino, Hiroshi; Atsumi, Takuto*; Uno, Masayoshi*
Proceedings of 28th International Conference on Nuclear Engineering (ICONE 28) (Internet), 6 Pages, 2021/08
In a postulated accident of fuel pin failure of sodium cooled fast reactor, a fission product cesium will be released from the failed pin as an aerosol such as cesium iodide and/or cesium oxide together with a fission product noble gas such as xenon and krypton. As the result, the xenon and krypton released with cesium aerosol into the sodium coolant as bubbles have an influence on the removal of cesium aerosol by the sodium pool in a period of bubble rising to the pool surface. In this study, cesium aerosol removal behavior due to inertial deposition, sedimentation and diffusion from a noble gas bubble rising through liquid sodium pool was analyzed by a computer program which deals with the expansion and the deformation of the bubble together with the aerosol absorption considering the effects of particle size distribution and agglomeration in aerosols. In the analysis, initial bubble diameter, sodium pool depth and temperature, aerosol particle diameter and density, initial aerosol concentration in the bubble were changed as parameter, and the results for the sensitivities of these parameters on decontamination factor (DF) of cesium aerosol were compared with the results of the previous study in which the effects of particle size distribution and agglomeration in aerosols were not considered. From the results, it was concluded that the sensitivities of initial bubble diameter, the aerosol particle diameter and density to the DF became significant due to the inertial deposition of agglomerated aerosols. To validate these analysis results, the simulation experiments have been conducted using a simulant particles of cesium aerosol under the condition of room temperature in water pool and air bubble systems. The experimental results were compared with the analysis results calculated under the same condition.
Zhang, T.*; Funakoshi, Kanji*; Liu, X.*; Liu, W.*; Morita, Koji*; Kamiyama, Kenji
Annals of Nuclear Energy, 150, p.107856_1 - 107856_10, 2021/01
Times Cited Count:7 Percentile:54.33(Nuclear Science & Technology)Ono, Ayako; Sakashita, Hiroto*; Yoshida, Hiroyuki
Heat Transfer Engineering, 42(21), p.1775 - 1788, 2021/00
Times Cited Count:6 Percentile:28.67(Thermodynamics)In this study, the macrolayer formation model is proposed to predict the critical heat flux in the saturated and subcooled pool boiling based on the macrolayer dryout model. This model concept is based on the results of the previous experiments. In the model, the nucleation site is assumed to distribute based on the Poisson distribution. Combining the proposed macrolayer formation model and macrolayer dryout model, the CHFs up to subcooling 40K were predicted and they are successfully good agreement with the experimental data. Moreover, the concept of the model was confirmed by the numerical simulation using the TPFIT.
Miyahara, Shinya*; Kawaguchi, Munemichi; Seino, Hiroshi
Proceedings of 2020 International Conference on Nuclear Engineering (ICONE 2020) (Internet), 6 Pages, 2020/08
In a postulated accident of fuel pin failure of sodium cooled fast reactor, a fission product cesium will be released as an aerosol such as cesium iodide and/or oxide together with xenon and/or krypton. In this study, cesium aerosol removal behavior due to inertial deposition, sedimentation and diffusion was analyzed by a computer program which deals with the expansion and the deformation of the bubble together with the aerosol absorption. Initial bubble diameter, sodium pool depth and temperature, aerosol particle diameter and density, initial aerosol concentration were changed as parameter. From the results, it was concluded that the initial bubble diameter was most sensitive parameter to the decontamination factor (DF). It was found that the sodium pool depth, the aerosol particle diameter and density have also important effect on the DF, but the sodium temperature has a marginal effect. To meet these results, the experiments are under planning to validate the results.
Suzuki, Takayuki*; Yoshida, Hiroyuki; Horiguchi, Naoki; Yamamura, Sota*; Abe, Yutaka*
Proceedings of 2020 International Conference on Nuclear Engineering (ICONE 2020) (Internet), 7 Pages, 2020/08
Kubo, Shigenobu; Chikazawa, Yoshitaka; Ohshima, Hiroyuki; Uchita, Masato*; Miyagawa, Takayuki*; Eto, Masao*; Suzuno, Tetsuji*; Matoba, Ichiyo*; Endo, Junji*; Watanabe, Osamu*; et al.
Mechanical Engineering Journal (Internet), 7(3), p.19-00489_1 - 19-00489_16, 2020/06
The authors are developing the design concept of pool-type sodium-cooled fast reactor (SFR) that addresses Japan's specific siting conditions such as earthquakes and meets safety design criteria (SDC) and safety design guidelines (SDGs) for Generation IV SFRs. The development of this concept will broaden not only options for reactor types in Japan but also the range and depth of international cooperation. A design concept of 1,500 MWt (650 MWe) class pool-type SFR was thought up by applying design technology obtained from the design of advanced loop-type SFR, named JSFR, equipped with safety measures that reflect results from the feasibility study on commercialized fast reactor cycle systems and fast reactor cycle technology development, improved maintainability and repairability, and lessons learned from the Fukushima Daiichi Nuclear Power Plants accident.
Kaji, Yoshiyuki; Nemoto, Yoshiyuki; Nagatake, Taku; Yoshida, Hiroyuki; Tojo, Masayuki*; Goto, Daisuke*; Nishimura, Satoshi*; Suzuki, Hiroaki*; Yamato, Masaaki*; Watanabe, Satoshi*
Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 8 Pages, 2019/05
In this research program, cladding oxidation model in SFP accident condition, and numerical simulation method to evaluate capability of spray cooling system which was deployed for spent fuel cooling during SFP accident, have been developed. These were introduced into the severe accident codes such as MAAP and SAMPSON, and SFP accident analyses were conducted. Analyses using Computational Fluid Dynamics (CFD) code were conducted as well for the comparison with SA code analyses and investigation of detail in the SFP accident. In addition, three-dimensional criticality analysis method was developed as well, and safer loading pattern of spent fuels in pool was investigated.
Kubo, Shigenobu; Chikazawa, Yoshitaka; Ohshima, Hiroyuki; Uchita, Masato*; Miyagawa, Takayuki*; Eto, Masao*; Suzuno, Tetsuji*; Matoba, Ichiyo*; Endo, Junji*; Watanabe, Osamu*; et al.
Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 8 Pages, 2019/05
The authors are developing the design concept of pool-type sodium-cooled fast reactor (SFR) that addresses Japan's specific siting conditions such as earthquakes and meets safety design criteria (SDC) and safety design guidelines (SDGs) for Generation IV SFRs. The development of this concept will broaden not only options for reactor types in Japan but also the range and depth of international cooperation. A design concept of 1,500 MWt (650 MWe) class pool-type SFR was thought up by applying design technology obtained from the design of advanced loop-type SFR, named JSFR, equipped with safety measures that reflect results from the feasibility study on commercialized fast reactor cycle systems and fast reactor cycle technology development, improved maintainability and repairability, and lessons learned from the Fukushima Daiichi Nuclear Power Plants accident.