Yokoyama, Kenji; Kitada, Takanori*
Proceedings of 2018 International Congress on Advances in Nuclear Power Plants (ICAPP 2018) (CD-ROM), p.1221 - 1230, 2018/04
no abstracts in English
Kugo, Teruhiko; Kojima, Kensuke; Ando, Masaki; Okajima, Shigeaki; Mori, Takamasa; Takeda, Toshikazu*; Kitada, Takanori*; Matsuoka, Shogo*
Proceedings of 2005 International Congress on Advances in Nuclear Power Plants (ICAPP '05) (CD-ROM), 10 Pages, 2005/05
We have preliminarily evaluated the reduction of prediction errors of the core characteristics of the breeding light water reactor core based on the bias factor method by utilizing the FCA critical experiments carried out for MOX fueled tight lattice light water reactor cores. The prediction uncertainty of k is reduced from 0.62% to 0.39% by utilizing the FCA-XV-2 (65V) result. As for the reaction rate ratio of
U capture and
Pu fission, it is found that the FCA XXII-1 (95V) and XV (95V) results are suitable for the upper core and the upper blanket of the real core and the FCA XXII-1 (65V) and XV-2 (65V) results are suitable for the lower core and the internal blanket.
Shibata, Yasushi*; Yamamoto, Kazuyoshi; Matsumura, Akira*; Yamamoto, Tetsuya*; Hori, Naohiko; Kishi, Toshiaki; Kumada, Hiroaki; Akutsu, Hiroyoshi*; Yasuda, Susumu*; Nakai, Kei*; et al.
JAERI-Research 2005-009, 41 Pages, 2005/03
The measurement of neutron flux and boron concentration in the blood during medical irradiation is indispensable in order to evaluate the radiation in boron neutron capture therapy. It is, however, difficult to measure the blood boron concentration during neutron irradiation because access to the patient is limited. Therefore we prospectively investigated the predictability of blood boron concentrations using the data obtained at the first craniotomy after infusion of a low dosage of BSH. When the test could not be carried out, the blood boron concentration during irradiation was also predicted by using the 2-compartment model. If the final boron concentration after the end of the infusion is within 95% confidence interval of the prediction, direct prediction from biexponential fit will reduce the error of blood boron concentrations during irradiation to around 6%. If the final boron concentration at 6 or 9 hours after the end of infusion is out of 95% confidence interval of the prediction, proportional adjustment will reduce error and expected error after adjustment to around 12%.