Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 32

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Development of a radioactive substance detection system integrating a Compton camera and a LiDAR camera with a hexapod robot

Sato, Yuki; Kakuto, Takeshi*; Tanaka, Takayuki*; Shimano, Hiroyuki*; Morohashi, Yuko; Hatakeyama, Tomoyoshi*; Nakajima, Junsaku; Ishiyama, Masahiro

Nuclear Instruments and Methods in Physics Research A, 1063, p.169300_1 - 169300_7, 2024/06

Journal Articles

Radioactivity estimation of multiple radiation sources using a Compton camera to investigate radioactively contaminated objects

Sato, Yuki

Applied Radiation and Isotopes, 203, p.111083_1 - 111083_9, 2024/01

 Times Cited Count:0 Percentile:0.01(Chemistry, Inorganic & Nuclear)

Journal Articles

Quantitative visualization of a radioactive plume with harmonizing gamma-ray imaging spectrometry and real-time atmospheric dispersion simulation based on 3D wind observation

Nagai, Haruyasu; Furuta, Yoshihiro*; Nakayama, Hiromasa; Satoh, Daiki

Journal of Nuclear Science and Technology, 60(11), p.1345 - 1360, 2023/11

 Times Cited Count:0 Percentile:0.01(Nuclear Science & Technology)

A novel monitoring method for the quantitative visualization of 3D distribution of a radioactive plume and source term estimation of released radionuclides is proposed and its feasibility is demonstrated by preliminary test. The proposed method is the combination of gamma-ray imaging spectroscopy with the Electron Tracking Compton Camera (ETCC) and real-time high-resolution atmospheric dispersion simulation based on 3D wind observation with Doppler lidar. The 3D distribution of a specific radionuclide in a target radioactive plume is inversely reconstructed from line gamma-ray images from each radionuclide by several ETCCs located around the target by harmonizing with the air concentration distribution pattern of the plume predicted by real-time atmospheric dispersion simulation. A prototype of the analysis method was developed, showing a sufficient performance in several test cases using hypothetical data generated by numerical simulations of atmospheric dispersion and radiation transport.

Journal Articles

Radiation imaging of a highly contaminated filter train inside Fukushima Daiichi Nuclear Power Station Unit 2 using an integrated Radiation Imaging System based on a Compton camera

Sato, Yuki; Terasaka, Yuta

Journal of Nuclear Science and Technology, 60(8), p.1013 - 1026, 2023/08

 Times Cited Count:5 Percentile:97.88(Nuclear Science & Technology)

Journal Articles

Radiation imaging using an integrated radiation imaging system based on a compact Compton camera under Unit 1/2 exhaust stack of Fukushima Daiichi Nuclear Power Station

Sato, Yuki; Terasaka, Yuta

Journal of Nuclear Science and Technology, 59(6), p.677 - 687, 2022/06

 Times Cited Count:17 Percentile:94.96(Nuclear Science & Technology)

Journal Articles

Visualization of radioactive substances using a freely moving gamma-ray imager based on Structure from Motion

Sato, Yuki; Minemoto, Kojiro*; Nemoto, Makoto*; Torii, Tatsuo

Journal of Nuclear Engineering and Radiation Science, 7(4), p.042003_1 - 042003_12, 2021/10

Journal Articles

3D position and radioactivity estimation of radiation source by a simple directional radiation detector combined with structure from motion

Sato, Yuki; Minemoto, Kojiro*; Nemoto, Makoto*

Radiation Measurements, 142, p.106557_1 - 106557_6, 2021/03

 Times Cited Count:2 Percentile:29.53(Nuclear Science & Technology)

Journal Articles

Automatic data acquisition for visualizing radioactive substances by combining a gamma-ray imager and an autonomous mobile robot

Sato, Yuki; Minemoto, Kojiro*; Nemoto, Makoto*; Torii, Tatsuo

Journal of Instrumentation (Internet), 16(1), p.P01020_1 - P01020_18, 2021/01

 Times Cited Count:1 Percentile:8.48(Instruments & Instrumentation)

Journal Articles

Remote detection of radioactive hotspot using a Compton camera mounted on a moving multi-copter drone above a contaminated area in Fukushima

Sato, Yuki; Ozawa, Shingo*; Terasaka, Yuta; Minemoto, Kojiro*; Tamura, Satoshi*; Shingu, Kazutoshi*; Nemoto, Makoto*; Torii, Tatsuo

Journal of Nuclear Science and Technology, 57(6), p.734 - 744, 2020/06

 Times Cited Count:20 Percentile:93.68(Nuclear Science & Technology)

Journal Articles

Visualization of radioactive substances using freely moving gamma-ray imager based on Structure from Motion

Sato, Yuki; Torii, Tatsuo

Proceedings of International Youth Nuclear Congress 2020 (IYNC 2020) (Internet), 4 Pages, 2020/05

Journal Articles

Radiation imaging using a compact Compton camera mounted on a crawler robot inside reactor buildings of Fukushima Daiichi Nuclear Power Station

Sato, Yuki; Terasaka, Yuta; Utsugi, Wataru*; Kikuchi, Hiroyuki*; Kiyooka, Hideo*; Torii, Tatsuo

Journal of Nuclear Science and Technology, 56(9-10), p.801 - 808, 2019/09

 Times Cited Count:56 Percentile:99.33(Nuclear Science & Technology)

Journal Articles

Journal Articles

Feasibility study on application of synchrotron radiation $$mu$$CT imaging to alloy steel for non-destructive inspection of inclusions

Shimamura, Yoshinobu*; Matsushita, Shinya*; Fujii, Tomoyuki*; Togo, Keiichiro*; Akita, Koichi*; Shobu, Takahisa; Shiro, Ayumi*

Metals, 9(5), p.527_1 - 527_9, 2019/05

 Times Cited Count:4 Percentile:22.80(Materials Science, Multidisciplinary)

Journal Articles

Image reconstruction of radioactive contamination due to the Fukushima-Daiichi Nuclear Power Station Accident using a compact Compton camera

Sato, Yuki; Terasaka, Yuta; Miyamura, Hiroko; Kaburagi, Masaaki; Tanifuji, Yuta; Kawabata, Kuniaki; Torii, Tatsuo

Reactor Dosimetry; 16th International Symposium on Reactor Dosimetry (ISRD-16) (ASTM STP 1608), p.428 - 436, 2018/11

 Times Cited Count:0 Percentile:0.05(Nuclear Science & Technology)

Journal Articles

Radiation imaging using a compact Compton camera inside the Fukushima Daiichi Nuclear Power Station building

Sato, Yuki; Tanifuji, Yuta; Terasaka, Yuta; Usami, Hiroshi; Kaburagi, Masaaki; Kawabata, Kuniaki; Utsugi, Wataru*; Kikuchi, Hiroyuki*; Takahira, Shiro*; Torii, Tatsuo

Journal of Nuclear Science and Technology, 55(9), p.965 - 970, 2018/09

 Times Cited Count:33 Percentile:96.48(Nuclear Science & Technology)

Journal Articles

A 3D radiation image display on a simple virtual reality system created using a game development platform

Sato, Yuki; Terasaka, Yuta; Ozawa, Shingo*; Tanifuji, Yuta; Torii, Tatsuo

Journal of Instrumentation (Internet), 13(8), p.T08011_1 - T08011_10, 2018/08

 Times Cited Count:6 Percentile:30.28(Instruments & Instrumentation)

Journal Articles

A Three-dimensional radiation image display on a real space image created via photogrammetry

Sato, Yuki; Ozawa, Shingo*; Tanifuji, Yuta; Torii, Tatsuo

Journal of Instrumentation (Internet), 13(3), p.P03001_1 - P03001_8, 2018/03

 Times Cited Count:7 Percentile:34.69(Instruments & Instrumentation)

Journal Articles

Remote radiation imaging system using a compact $$gamma$$-ray imager mounted on a multicopter drone

Sato, Yuki; Ozawa, Shingo*; Terasaka, Yuta; Kaburagi, Masaaki; Tanifuji, Yuta; Kawabata, Kuniaki; Miyamura, Hiroko; Izumi, Ryo*; Suzuki, Toshikazu*; Torii, Tatsuo

Journal of Nuclear Science and Technology, 55(1), p.90 - 96, 2018/01

 Times Cited Count:43 Percentile:98.01(Nuclear Science & Technology)

Journal Articles

Development of compact Compton camera for 3D image reconstruction of radioactive contamination

Sato, Yuki; Terasaka, Yuta; Ozawa, Shingo*; Miyamura, Hiroko; Kaburagi, Masaaki; Tanifuji, Yuta; Kawabata, Kuniaki; Torii, Tatsuo

Journal of Instrumentation (Internet), 12(11), p.C11007_1 - C11007_8, 2017/11

 Times Cited Count:19 Percentile:66.46(Instruments & Instrumentation)

32 (Records 1-20 displayed on this page)