竹田 武司; 大津 巌
Proceedings of 25th International Conference on Nuclear Engineering (ICONE-25) (CD-ROM), 11 Pages, 2017/07
An experiment focusing on nitrogen gas behavior during reflux cooling in a PWR was performed with the LSTF. The test conditions were made such as the constant core power of 0.7% of the volumetric-scaled PWR nominal power and the primary pressure of lower than 1 MPa. The steam generator (SG) secondary-side collapsed liquid level was maintained at a certain liquid level above the SG tube height. Nitrogen gas was injected stepwise into each SG inlet plenum at a certain constant amount. The primary pressure and the SG U-tube fluid temperatures were greatly dependent on the amount of nitrogen gas accumulated in the SG U-tubes. Non-uniform flow behavior was observed among the SG U-tubes with nitrogen gas ingress. The RELAP5/MOD3.3 code indicated remaining problems in the predictions of the primary pressure and the SG U-tube fluid temperatures after nitrogen gas inflow.
早田 邦久
Journal of Nuclear Science and Technology, 19(10), p.813 - 820, 1982/00
被引用回数:4 パーセンタイル:47.30(Nuclear Science & Technology)加圧水型原子炉(PWR)の自然循環は、TMI事故後、強制循環を喪失するような事故または遷移時の代替冷却法として、また、回復手段として、近年大きな関心を集めてきた。自然循環の3つのモード(単相、二相、リフラックス)のうち、リフラックス冷却については、PWRでの十分な検討がされていない。本報告では、自然循環のリフラックス冷却に注目し、PWRのホットレグ内の液速を推定する解析方法を導いた。本報告の結果から、代表的なPWRのリフラックッス時(2%炉心出力、6.9MPa)には、上部プレナム側のホットレグ入口で、流速は2.7m/s、液深さは、3.0cmであることがわかった。この結果から、蒸気流路の凝縮液流による閉塞は、ホットレグ内で殆んどおこらないことがわかった。この結果は、リフラックス冷却実験を行なう実験装置で、液連および液深さを測定する計測器を設計するのにも有用である。