Ohira, Hiroaki; Doda, Norihiro; Kamide, Hideki; Iwasaki, Takashi*; Minami, Masaki*
Proceedings of 2015 International Congress on Advances in Nuclear Power Plants (ICAPP 2015) (CD-ROM), p.2585 - 2592, 2015/05
IAEA's Coordinated Research Project on Benchmark Analyses of Shutdown Heat Removal Test (SHRT) performed at the Experimental Breeder Reactor-II (EBR-II) has been carried out since 2012. The benchmark specifications were provided by the Argonne National Laboratory (ANL) and the model development for thermal-hydraulics codes and/or plant dynamics codes has been conducted by participating organizations. The experimental data were also provided by the ANL after the calculations have been performed as the blind simulation. JAEA participated in this benchmark analyses, and the plant dynamics analysis code; Super-COPD was applied to the SHRT-17 simulation. The calculated inlet temperature of the high pressure plenum agreed well with the test data in all simulation time. Although the Z-pipe inlet temperature and the IHX intermediate outlet temperature had some discrepancy in the first 400 sec. caused by larger mass flow rate of the primary pump and the perfect mixing model of upper plenum, these temperatures and the flow rate agreed well with the measured data after 400 sec. Hence it was concluded the present analytical model could predict the natural circulation in good accuracy.