Kobayashi, Jun; Aizawa, Kosuke; Ezure, Toshiki; Nagasawa, Kazuyoshi*; Kurihara, Akikazu; Tanaka, Masaaki
JAEA-Research 2022-009, 125 Pages, 2023/01
The design studies of an advanced loop-type sodium-cooled fast reactor (Advanced- SFR) have been carried out by the Japan Atomic Energy Agency (JAEA). At the core outlet, temperature fluctuations occur due to mixing of hot sodium from the fuel assembly with cold sodium from the control rod channels and radial blanket assembly. These temperature fluctuations may cause high cycle thermal fatigue around a bottom of Upper Internal Structure (UIS) located above the core. Therefore, we conducted a water experiment using a 1/3 scale 60 degree sector model that simulated the upper plenum of the advanced loop-type sodium-cooled reactor. And we proposed some countermeasures against large temperature fluctuations that occur at the bottom of the UIS. In this report, we have summarized that the effect of the countermeasure structure to mitigate the temperature fluctuation generated at the bottom of UIS is confirmed, and the Reynolds number dependency of the countermeasure structure and the characteristics of the temperature fluctuation on the control rod surface.
Kobayashi, Jun; Aizawa, Kosuke; Ezure, Toshiki; Kurihara, Akikazu; Tanaka, Masaaki
Hozengaku, 20(3), p.89 - 96, 2021/10
Hot sodium from the fuel assembly can mix with cold sodium from the control rod (CR) channel and the blanket assemblies at the bottom plate of the Upper Internal Structure (UIS) of Advanced-SFR. Temperature fluctuation due to mixing of the fluids at different temperature between the core outlet and cold channel may cause high cycle thermal fatigue on the structure around the bottom of UIS. A water experiment using a 1/3 scale 60 degree sector model simulating the upper plenum of the Advanced-SFR has been conducted to examine countermeasures for the significant temperature fluctuation generated around the bottom of UIS. We focused on the temperature fluctuations near the primary and backup control rod channels, and studied the countermeasure structure to mitigate the temperature fluctuation through temperature distribution and flow velocity distribution measurements. As a result, effectiveness of the countermeasure to mitigate the temperature fluctuation intensity was confirmed.
Kobayashi, Jun; Aizawa, Kosuke; Ezure, Toshiki; Kurihara, Akikazu; Tanaka, Masaaki
Hozengaku, 20(3), p.97 - 101, 2021/10
Focusing on the thermal striping phenomena that occurs at a bottom of the internal structure of an advanced sodium-cooled fast reactor (Advanced-SFR) that has been designed by the Japan Atomic Energy Agency, a water experiment using a 1/3 scale 60 degree sector model simulating the upper plenum of the Advanced-SFR has been conducted to examine countermeasures for the significant temperature fluctuation generated around the bottom of Upper Internal Structure (UIS). In the previous paper, we reported the effect of measures to mitigate temperature fluctuations around the control rod channels. In this paper, the same test section was used, and a water experiment was conducted to obtain the characteristics of temperature fluctuations around the radial blanket fuel assembly. And the shape of the Core Instrumentation Support Plate (CIP) was modified, and it was confirmed that it was highly effective in alleviating temperature fluctuations around the radial blanket fuel assembly.
Kobayashi, Jun; Ezure, Toshiki; Tanaka, Masaaki; Kamide, Hideki
Proceedings of 10th Japan-Korea Symposium on Nuclear Thermal Hydraulics and Safety (NTHAS-10) (USB Flash Drive), 5 Pages, 2016/11
JAEA has been conducting a design study for an advanced large-scale sodium-cooled fast reactor (SFR). Hot sodium from the fuel subassembly can mix with the cold sodium from the control rod (CR) channel at the bottom of Upper Internal Structure (UIS). Temperature fluctuation due to the fluid mixing at the core outlet may cause high cycle thermal fatigue at the bottom of UIS. JAEA had performed a water experiment to examine countermeasures for the significant temperature fluctuation generated at the bottom of SFRs UIS. Meanwhile, a self-actuated shutdown system (SASS) is equipped in a backup control rod (BCR) channel to ensure reactor shutdown. The BCR guide tubes have a flow guide structure "flow-collector" to provide reliable operation of SASS. Flow-collector may affect the thermal mixing behavior at the bottom of the UIS. This study has investigated the influence of the flow- collector on characteristics of the temperature fluctuation around the BCR channels.
Kobayashi, Jun; Tanaka, Masaaki; Ohno, Shuji; Ohshima, Hiroyuki; Kamide, Hideki
Proceedings of 16th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-16) (USB Flash Drive), p.6664 - 6677, 2015/08
Numerical simulation is recognized an essential tool for the physical phenomena analysis and plant design study of a sodium-cooled fast reactor (SFR). In order to enhance credibility of the numerical results in the activities for plant design by using numerical simulations, it is recognized that verification and validation (V&V) process is very important. In this study, experiments for planar triple parallel jets mixing phenomena conducted in JAEA were proposed as benchmark problems for the code validation in the area of thermal striping study in the SFR development.
Kobayashi, Jun; Ezure, Toshiki; Kamide, Hideki; Oyama, Kazuhiro*; Watanabe, Osamu*
Proceedings of 23rd International Conference on Nuclear Engineering (ICONE-23) (DVD-ROM), 6 Pages, 2015/05
A column type upper internal structure (UIS) is installed in the upper plenum of reactor vessel in JSFR. High cycle thermal fatigue may occur at the bottom plate (CIP) of the UIS where the hot sodium from the fuel subassembly can mix with the cold sodium from the control rod channel and the blanket fuel subassembly. We have been conducted a water experiment using a reactor upper plenum model to grasp the thermal-hydraulic phenomena around control rod (CR) channels, and to obtain countermeasures for significant temperature fluctuation on the CIP. The experimental apparatus has 1/3 scale and 60 sector model of the reactor upper plenum. By the experiment, characteristics of fluid temperature fluctuation between the handling head of the assemblies and the CIP are measured and countermeasure for the significant temperature fluctuation generation will be discussed on the influence of the distance from the handling head outlet to the lower surface of the CIP.