Takei, Hayanori; Kobayashi, Hitoshi*
Journal of Nuclear Science and Technology, 42(12), p.1032 - 1039, 2005/12
Times Cited Count:3 Percentile:24.78(Nuclear Science & Technology)In high-intensity proton accelerator facilities, a failure of an electromagnet that steers beam pulses may result in thermal shock damage on the accelerator component by injecting an out-of-control pulse. It is important that a Machine Protection System (MPS) is appropriately designed to prevent this damage in the facilities such as Japan Proton Accelerator Research Complex (J-PARC). In this study, the simple evaluation method for the allowable injection time before the operation of the MPS was derived from the relation between the thermal stress and the yield stress of materials.The derived evaluation method was then applied to J-PARC. The allowable injection time for each component ranged from 0.1 to 70 s.
*; Nakajima, Hajime; ; ; Kondo, Tatsuo
Corrosion Fatigue; Mechanics, Metallurgy, Electrochemistry and Engineering, p.256 - 286, 1983/00
no abstracts in English
; ; ;
JAERI-M 7629, 35 Pages, 1978/04
no abstracts in English