Matsuba, Kenichi; Isozaki, Mikio; Kamiyama, Kenji; Suzuki, Toru; Tobita, Yoshiharu
Proceedings of 11th International Topical Meeting on Nuclear Reactor Thermal Hydraulics, Operation and Safety (NUTHOS-11) (USB Flash Drive), 8 Pages, 2016/10
In order to evaluate the distance for fragmentation of molten core material discharged into the lower sodium plenum during core disruptive accidents in sodium-cooled fast reactors, experiments with simulated molten materials and coolants (water, sodium) was carried out, where an empirical correlation of the distance for fragmentation was developed. The empirical correlation developed by this study showed a good agreement with the measurement results obtained by the present experiments. It was found that in order to well-predict the distance for fragmentation in sodium, thermal phenomena, such as sodium boiling and resultant vapor expansion, needed to be considered.
Matsuba, Kenichi; Isozaki, Mikio; Kamiyama, Kenji; Tobita, Yoshiharu
Journal of Nuclear Science and Technology, 53(5), p.707 - 712, 2016/05
Times Cited Count:11 Percentile:75.73(Nuclear Science & Technology)In order to develop an evaluation method of the distance for fragmentation of molten core material discharged into the sodium plenum, a sodium experiment with visual observation was conducted using an X-ray imaging system. In the current experiments, 0.9 kg of molten aluminum (initial temperature: around 1473 K) was discharged into a sodium pool (initial temperature: 673 K) through a nozzle (inner diameter: 20 mm). Based on the experimental results, the distance for fragmentation of the liquid column was estimated to be 100 mm in the experiments. Through the sodium experiment, useful knowledge was obtained for the future development of an evaluation method of the distance for fragmentation of molten core material. As a next step, sodium experiments using higher-density molten materials will be conducted to enrich the experimental knowledge. Besides, a new semi-empirical correlation will be developed to evaluate more appropriately the distance for fragmentation under CDA conditions.
Matsuba, Kenichi; Isozaki, Mikio; Kamiyama, Kenji; Suzuki, Toru; Tobita, Yoshiharu
Proceedings of 10th International Topical Meeting on Nuclear Thermal Hydraulics, Operation and Safety (NUTHOS-10) (USB Flash Drive), 7 Pages, 2014/12
In order to develop an evaluation method of the distance for fragmentation of molten core material discharged into the sodium plenum, a sodium experiment with visual observation was conducted using an X-ray imaging system. In the current experiments, 0.9 kg of molten aluminum (initial temperature: around 1473 K) was discharged into a sodium pool (initial temperature: 673 K) through a nozzle (inner diameter: 20 mm). Based on the experimental results, the distance for fragmentation of the liquid column was estimated to be 100 mm in the experiments. Through the sodium experiment, useful knowledge was obtained for the future development of an evaluation method of the distance for fragmentation of molten core material. As a next step, sodium experiments using higher-density molten materials will be conducted to enrich the experimental knowledge. Besides, a new semi-empirical correlation will be developed to evaluate more appropriately the distance for fragmentation under CDA conditions.