Terada, Atsuhiko; Nagaishi, Ryuji
Journal of Nuclear Science and Technology, 61(8), p.1135 - 1154, 2024/08
Times Cited Count:0 Percentile:0.00(Nuclear Science & Technology)In order to elucidate ventilation and exhaust of hydrogen leaked in a partially open space practically, the effects of outer wind on them were studied analytically by using a CFD code in the room of experimental Half-size Hallway model, which has a H release hole on the bottom, one vent on the roof and another vent on the side: external air flowed in the room from the Door vent and then H
was discharged outside from the Roof vent. The H
concentration distribution in the room was divided into two layers at the height of Door vent, with a high concentration layer above it and a low concentration layer below it, forming a stratified interface. When the wind speed blown into the room increased, the combination of the Realizable k-e; turbulence model and the turbulence Schmidt number of 1.0 improved the reproducibility of the analysis results of H
concentration distribution. The trial analysis suggested that the concern that wind would increase the indoor H
concentration could be reduced by using the plate with a simple structure in which two plates were crossed on the Roof vent.