Harada, Masahide; Teshigawara, Makoto; Oi, Motoki; Oikawa, Kenichi; Takada, Hiroshi; Ikeda, Yujiro
Nuclear Instruments and Methods in Physics Research A, 1000, p.165252_1 - 165252_8, 2021/06
Times Cited Count:4 Percentile:38.40(Instruments & Instrumentation)This study explores high-energy neutron components of the extracted neutron beam at J-PARC pulsed neutron source using the foil activation method with threshold reactions. Foils of aluminum, gold, bismuth, niobium, and thulium were used to cover the neutron energy range from 0.3 MeV to 79.4 MeV. The experiment was performed using neutron beams of BL10 (NOBORU). The foils were irradiated by a neutron beam at 13.4 m from the moderator. To characterize high-energy neutron fields for irradiation applications, reaction rates in three different configurations with and without BC slit and Pb filter were examined. To compare the experiments with calculations given for the user, reaction rates for corresponding reactions were calculated by the PHITS code with the JENDL-3.2 and the JENDL dosimetry file. Although there was a systematic tendency in C/E (Calculation/Experiment) ratios for different threshold energies, which C/E ratio decreased as threshold energy increased up to 100 MeV, and all C/E ratios were in the range of 1.0
0.2. This indicated that high-energy neutron calculations were adequate for the analysis of experimental data for NOBORU users.
Katano, Ryota; Yamanaka, Masao*; Pyeon, C. H.*
Journal of Nuclear Science and Technology, 57(2), p.169 - 176, 2020/02
Times Cited Count:4 Percentile:36.10(Nuclear Science & Technology)We proposed the linear combination method as a subcriticality measurement method which estimates the prompt neutron decay constant () correlated with the subcriticality using measurement results obtained at multiple detector positions. In the previous study, we confirmed applicability of the linear combination method through the pulsed neutron experiment with DT neutron source at Kyoto University Critical Assembly (KUCA). In this study, we conduct the pulsed neutron source experiment with spallation neutrons at KUCA and confirm the robustness of the linear combination to neutron sources.
Katano, Ryota; Yamanaka, Masao*; Pyeon, C. H.*
Nuclear Science and Engineering, 193(12), p.1394 - 1402, 2019/12
Times Cited Count:6 Percentile:43.37(Nuclear Science & Technology)The author proposed the linear combination method as a subcriticality measurement method which estimates the prompt neutron decay constant (alpha) correlated with the subcriticality using measurement results obtained at multiple detector positions. In this study, we conduct the pulsed neutron experiment at Kyoto University Critical Assembly (KUCA) and measure alpha by the linear combination method using measured neutron counts. Through experiment, we experimentally show that the linear combination method can reduce the higher-mode effect compared to the conventional method. In addition, experimentally show that the linear combination has capability of the different mode extraction.
Aso, Tomokazu; Tatsumoto, Hideki*; Otsu, Kiichi*; Kawakami, Yoshihiko*; Komori, Shinji*; Muto, Hideki*; Takada, Hiroshi
JAEA-Technology 2019-013, 77 Pages, 2019/09
At Materials and Life Science experimental Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC), a 1-MW pulsed spallation neutron source is equipped with a cryogenic hydrogen system which circulates liquid hydrogen (20 K and 1.5 MPa) to convert high energy neutrons generated at a mercury target to cold neutrons at three moderators with removing nuclear heat of 3.8 kW deposited there. The cryogenic system includes an accumulator with a bellows structure in order to absorb pressure fluctuations generated by the nuclear heat deposition in the system. Welded inner bellows of the first accumulator was failured during operation, forcing us to improve the accumulator to have sufficient pressure resistance and longer life-time. We have developed elemental technologies for manufacturing welded bellows of the accumulator by a thick plate with high pressure resistance, succeeding to find optimum welding conditions. We fabricated a prototype bellows block and carried out an endurance test by adding a pressure change of 2 MPa repeatedly. As a result, the prototype bellows was successfully in use exceeding the design life of 10,000 times. Since distortions given during welding and assembling affect functionality and lifetime of the bellows, we set the levelness of each element of the bellows as within 0.1. The improved accumulator has already been in operation for about 25,000 hours as of January 2019, resulting that the number of strokes reached to 16,000. In July 2018, we demonstrated that the accumulator could suppress the pressure fluctuation generated by the 932 kW beam injection as designed. As current operational beam power is 500 kW, the current cryogenic hydrogen system could be applicable for stable operation at higher power in the future.
Katano, Ryota
Proceedings of 27th International Conference on Nuclear Engineering (ICONE-27) (Internet), 6 Pages, 2019/05
no abstracts in English
Ikeda, Yujiro; Shimizu, Hirohiko*
Reza Kenkyu, 46(11), p.641 - 646, 2018/11
In viewing significant progresses in technical achievement toward a high-intensity neutron source driven by a high-power laser came up with the high power laser development, we have reviewed the currently most advanced moderator system and neutron optics, which are the key elements for the neutron beam applications. Regarding the moderators, concepts adopted in J-PARC pulsed neutron source, which is one of most advanced system, were described to give a baseline design. Also a new direction of moderator concept is shown, which could be a high brightness candidate for the high-intensity laser driven system. On the neutron optics, the most fundamental consideration is primarily reviewed along with recent progress in new devises for enrichment of neutron-beam characteristics.
Harada, Masahide; Teshigawara, Makoto; Oi, Motoki; Klinkby, E.*; Zanini, L.*; Batkov, K.*; Oikawa, Kenichi; Toh, Yosuke; Kimura, Atsushi; Ikeda, Yujiro
Nuclear Instruments and Methods in Physics Research A, 903, p.38 - 45, 2018/09
Times Cited Count:13 Percentile:73.09(Instruments & Instrumentation)Teshigawara, Makoto; Ikeda, Yujiro; Oi, Motoki; Harada, Masahide; Takada, Hiroshi; Kakishiro, Masanori*; Noguchi, Gaku*; Shimada, Tsubasa*; Seita, Kyoichi*; Murashima, Daisuke*; et al.
Nuclear Materials and Energy (Internet), 14, p.14 - 21, 2018/01
Times Cited Count:0 Percentile:0.00(Nuclear Science & Technology)We developed an Au-In-Cd (AuIC) decoupler material to reduce induced radioactivity instead of Ag-In-Cd one, which has a cut off energy of 1eV. In order to implement it into an actual moderator-reflector assembly, a number of critical engineering issues need to be resolved with regard to large-sized bonding between AuIC and A5083 alloys by the hot isostatic pressing process. We investigated this process in terms of the surface conditions, sizes, and heat capacities of large AuIC alloys. We also show a successful implementation of an AuIC decoupler into a reflector assembly, resulting in a remarkable reduction of radioactivity by AuIC compared to AIC without sacrificing neutronic performance.
Iwamoto, Hiroki; Nishihara, Kenji; Yagi, Takahiro*; Pyeon, C.-H.*
Journal of Nuclear Science and Technology, 54(4), p.432 - 443, 2017/04
Times Cited Count:20 Percentile:86.43(Nuclear Science & Technology)Oba, Yojiro*; Morooka, Satoshi; Sato, Hirotaka*; Sato, Nobuhiro*; Inoue, Rintaro*; Sugiyama, Masaaki*
Hamon, 26(4), p.170 - 173, 2016/11
Takada, Hiroshi; Naoe, Takashi; Kai, Tetsuya; Kogawa, Hiroyuki; Haga, Katsuhiro
Proceedings of 12th International Topical Meeting on Nuclear Applications of Accelerators (AccApp '15), p.297 - 304, 2016/00
In J-PARC, we have continuously been making efforts to operate a mercury target of a pulsed spallation neutron source with rated power of 1-MW. One of technical progresses is to mitigate cavitation damages at the target vessel front induced by the 3-GeV proton beam injection at 25 Hz. We have improved the performance of a gas micro-bubbles injection into the mercury target, resulting that no significant cavitation damages was observed on the inner surface of target vessel after operation for 2050 MWh with the 300-kW proton beam. Another progress is to suppress the release of gaseous radioactive isotopes, especially tritium, during the target vessel replacement. We have introduced a procedure to evacuate the target system by an off-gas processing apparatus when it is opened during the replacement operation, achieving to suppress the tritium release through the stack. For example, the amount of released tritium was 12.5 GBq, only 5.4% of the estimated amount, after the 2050 MWh operation. After these progresses, the operating beam power for the pulsed spallation neutron source was ramped up to 500-kW in April, 2015.
Koppitz, T.*; Jung, P.*; Mller, G.*; Weisenburger, A.*; Futakawa, Masatoshi; Ikeda, Yujiro
Journal of Nuclear Materials, 343(1-3), p.92 - 100, 2005/08
Times Cited Count:7 Percentile:44.26(Materials Science, Multidisciplinary)Cavitation damage of structural materials due to pressure waves is expected to be one of the majior life-time limiting factors in high power liquid metal spallation targets under pulsed operation. Two methods are developed for the European Spallation Source (ESS) to mitigate this damage: Introduction of gas bubbles to surpress the pressure pulse and surface-hardening of structural materials. Surface-hardening of four 8-13%Cr martenstic steels was examined by thermal treatment with pulsed or scanned electron- and laser-beams as well as by nitriding in plasma. A specimens of the 12%Cr steel were tested in liquid mercury under pulsed proton irradiation, and under mechanical pulsed-loading. Surface damage was analysed by optical, confocal-laser, or scanning-electron microscopy, showing in both tests much better resistance of the hardened material compared to standard condition.
Verzilov, Y. M.; Ochiai, Kentaro; Klix, A.; Sato, Satoshi; Wada, Masayuki*; Yamauchi, Michinori*; Nishitani, Takeo
Journal of Nuclear Materials, 329-333(Part2), p.1337 - 1341, 2004/08
Times Cited Count:4 Percentile:28.86(Materials Science, Multidisciplinary)no abstracts in English
Shibata, Kaoru; Tamura, Itaru; Soyama, Kazuhiko; Arai, Masatoshi; Middendorf, H. D.*; Niimura, Nobuo
Proceedings of ICANS-XVI, Volume 1, p.351 - 354, 2003/07
In this research report we describe the design of DYANA, a new neutron spectrometer dedicated for biology, biomaterials, and related soft-matter studies, which will be installed in the material and life science experimental facility project at the JAERI Tokai establishment. The DYANA spectrometer is an indirect-geometry crystal-analyzer instrument and its energy and momentum transfer range are from several 10eV to several meV and from 0.1
to several
, respectively. These specifications will become possible to do the study of protein dynamics analysis.
Shibata, Kaoru; Tamura, Itaru; Soyama, Kazuhiko; Arai, Masatoshi; Niimura, Nobuo
JAERI-Research 2002-036, 30 Pages, 2003/03
In this research report we describe the design of DYANA, a new neutron spectrometer dedicated for biology, biomaterials, and related soft-matter studies, which will be installed in the material and life science experimental facility project at the JAERI Tokai establishment. The DYANA spectrometer is an indirect-geometry crystal-analyzer instrument and it's energy and momentum transfer range are from several 10eV to several meV and from 0.1
to several
, respectively. These specifications will become possible to do the study of protein dynamics analysis.
Tonoike, Kotaro; Miyoshi, Yoshinori; Kikuchi, Tsukasa*; Yamamoto, Toshihiro
Journal of Nuclear Science and Technology, 39(11), p.1227 - 1236, 2002/11
Times Cited Count:21 Percentile:76.88(Nuclear Science & Technology)Kinetic parameter of low enriched uranyl nitrate solution was measured by the pulsed neutron source method in the STACY. This measurement was repeated systematically over several uranium concentrations from 193.7 gU/
to 432.1 gU/
. Used core tanks were two cylindrical tanks whose diameters are 600 mm and 800 mm and one slab tank which has 280 mm thickness and 700 mm width. In this report, experimental data such as solution conditions, critical solution level for each solution condition, subcritical solution levels where measurements were conducted, measured decay time constants of prompt neutron and extrapolated
values are described as well as basic principle of the pulsed neutron source method.
values were evaluated also by computation with the diffusion code CITATION in SRAC and the nuclear data library JENDL 3.2. Both experimental and computational
values show good agreement.
Harada, Masahide; Teshigawara, Makoto; Kai, Tetsuya; Sakata, Hideaki*; Watanabe, Noboru; Ikeda, Yujiro
Journal of Nuclear Science and Technology, 39(8), p.827 - 837, 2002/08
Times Cited Count:19 Percentile:74.08(Nuclear Science & Technology)For a decoupled hydrogen (super critical) moderator, optimization studies have been performed on a premoderator and reflector material (Pb, Be, Fe and Hg) together with the decoupling energy to realize a higher neutronic performance. The result indicated that the best neutronic performance could be obtained for a decoupled H moderator in a Pb reflector by optimizing the premoderator and adopting an appropriate decoupling energy, even compared with optimized one in a Be reflector.
Kai, Tetsuya; Teshigawara, Makoto; Watanabe, Noboru; Harada, Masahide; Sakata, Hideaki*; Ikeda, Yujiro
Journal of Nuclear Science and Technology, 39(2), p.120 - 128, 2002/02
Times Cited Count:13 Percentile:62.59(Nuclear Science & Technology)no abstracts in English
Teshigawara, Makoto; Meigo, Shinichiro; Sakata, Hideaki*; Kai, Tetsuya; Harada, Masahide; Ikeda, Yujiro; Watanabe, Noboru
JAERI-Research 2001-022, 33 Pages, 2001/05
no abstracts in English
Harada, Masahide; Teshigawara, Makoto; Kai, Tetsuya; Sakata, Hideaki*; Watanabe, Noboru; Ikeda, Yujiro
JAERI-Research 2001-016, 32 Pages, 2001/03
An optimization study on the premoderator, the reflector material choice and a length of the liner is carried out for the design of high performance decoupled hydrogen moderator. NMTC/JAM and MCNP-4C are used for the neutronics calculation. The result indicates that, assuming premoderator dimensions and decoupling energy is controlled, the decoupled hydrogen moderator with a premoderator can provide better pulse characteristics than that without the premoderator for a Be reflector. On the selection of the reflector material, it is clearly shown that Pb and Hg reflectors give merits in using the premoderator for higher intensity and reduction of energy deposition in moderator. It is also shown that a H2O premoderator provides a short tail while a D2O premoderator provides the high peak intensity. Minimum liner length is evaluated to be 20 cm from the viewpoint of neutronics.