Refine your search:     
Report No.
 - 
Search Results: Records 1-6 displayed on this page of 6
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Measurements of capture cross-section of $$^{93}$$Nb by activation method and half-life of $$^{94}$$Nb by mass analysis

Nakamura, Shoji; Shibahara, Yuji*; Endo, Shunsuke; Kimura, Atsushi

Journal of Nuclear Science and Technology, 60(11), p.1361 - 1371, 2023/11

 Times Cited Count:1 Percentile:68.31(Nuclear Science & Technology)

The thermal-neutron capture cross section ($$sigma$$$$_{0}$$) and resonance integral (I$$_{0}$$) for $$^{93}$$Nb among nuclides for decommissioning were measured by an activation method and the half-life of $$^{94}$$Nb by mass analysis. Niobium-93 samples were irradiated with a hydraulic conveyer installed in the research reactor in Institute for Integral Radiation and Nuclear Science, Kyoto University. Gold-aluminum, cobalt-aluminum alloy wires were used to monitor thermal-neutron fluxes and epi-thermal Westcott's indexes at an irradiation position. A 25-$$mu$$m-thick gadolinium foil was used to sort out reactions ascribe to thermal-and epi-thermal neutrons. Its thickness provided a cut-off energy of 0.133 eV. In order to attenuate radioactivity of $$^{182}$$Ta due to impurities, the Nb samples were cooled for nearly 2 years. The induced radio activity in the monitors and Nb samples were measured by $$gamma$$-ray spectroscopy. In analysis based on Westcott's convention, the $$sigma$$$$_{0}$$ and I$$_{0}$$ values were derived as 1.11$$pm$$0.04 barn and 10.5$$pm$$0.6 barn, respectively. After the $$gamma$$-ray measurements, mass analysis was applied to the Nb sample to obtain the reaction rate. By combining data obtained by both $$gamma$$-ray spectroscopy and mass analysis, the half-life of $$^{94}$$Nb was derived as (2.00$$pm$$0.15)$$times$$10$$^{4}$$ years.

Journal Articles

Thermal-neutron capture cross sections and resonance integrals of the $$^{243}$$Am(n,$$gamma$$)$$^{rm 244g}$$Am and $$^{243}$$Am(n,$$gamma$$)$$^{rm 244m+g}$$Am reactions

Nakamura, Shoji; Shibahara, Yuji*; Endo, Shunsuke; Kimura, Atsushi

Journal of Nuclear Science and Technology, 58(3), p.259 - 277, 2021/03

 Times Cited Count:5 Percentile:52.81(Nuclear Science & Technology)

Research and development were made for accuracy improvement of neutron capture cross section data on $$^{243}$$Am among minor actinides. First, the emission probabilities of decay $$gamma$$ rays were obtained with high accuracy, and the amount of the ground state of $$^{244}$$Am produced by reactor neutron irradiation of $$^{243}$$Am was examined by $$gamma$$-ray measurement. Next, the total amount of isomer and ground states was examined by $$alpha$$-ray measurement. Thermal-neutron capture cross sections and resonance integrals were derived both for the $$^{243}$$Am(n,$$gamma$$)$$^{rm 244g}$$Am and for $$^{243}$$Am(n,$$gamma$$)$$^{rm 244m+g}$$Am reactions.

Journal Articles

Measurement of cesium isotopic ratio by thermal ionization mass spectrometry for neutron capture reaction studies on $$^{135}$$Cs

Shibahara, Yuji*; Nakamura, Shoji; Uehara, Akihiro*; Fujii, Toshiyuki*; Fukutani, Satoshi*; Kimura, Atsushi; Iwamoto, Osamu

Journal of Radioanalytical and Nuclear Chemistry, 325(1), p.155 - 165, 2020/07

 Times Cited Count:8 Percentile:70.65(Chemistry, Analytical)

The measurements of isotopic ratios of Cs samples by thermal ionization mass spectrometry were performed for the analysis of their samples used to evaluate nuclear data obtained for $$^{135}$$Cs. To obtain a high intensity and stable ion beam, the effects of additive agents on the ionization of Cs were examined. The effect of silicotungstic acid on the ionization of Cs was the largest among the additive agents studied in the present study, while the silicotungstic acid also showed the largest isobaric interference of polyatomic ions. It was demonstrated that as small as 2$$times$$10$$^{-13}$$ g of a Cs sample was sufficient to achieve the analytical precision required to measure the $$^{135}$$Cs/$$^{137}$$Cs ratio in the case where an additive agent of TaO/glucose was employed. After examining of the analytical conditions, such as the interference effect due to Ba, the measurements of the isotopic ratios of two Cs samples used in our study using TIMS were conducted, and it was discussed how much the ratios contributed to evaluation of the neutron capture cross-section of $$^{135}$$Cs.

Journal Articles

Measurements of thermal-neutron capture cross-section of cesium-135 by applying mass spectrometry

Nakamura, Shoji; Shibahara, Yuji*; Kimura, Atsushi; Iwamoto, Osamu; Uehara, Akihiro*; Fujii, Toshiyuki*

Journal of Nuclear Science and Technology, 57(4), p.388 - 400, 2020/04

 Times Cited Count:3 Percentile:31.36(Nuclear Science & Technology)

The thermal-neutron capture cross-section ($$sigma_{0}$$) and resonance integral(I$$_{0}$$) were measured for the $$^{135}$$Cs(n,$$gamma$$)$$^{136}$$Cs reaction by an activation method and mass spectrometry. We used $$^{135}$$Cs contained as an impurity in a normally available $$^{137}$$Cs standard solution. An isotope ratio of $$^{135}$$Cs and $$^{137}$$Cs in a standard $$^{137}$$Cs solution was measured by mass spectrometry to quantify $$^{135}$$Cs. The analyzed $$^{137}$$Cs samples were irradiated at the hydraulic conveyer of the research reactor in Institute for Integral Radiation and Nuclear Science, Kyoto University. Wires of Co/Al and Au/Al alloys were used as neutron monitors to measure thermal-neutron fluxes and epi-thermal Westcott's indices at an irradiation position. A gadolinium filter was used to measure the $$sigma_{0}$$, and a value of 0.133 eV was taken as the cut-off energy. Gamma-ray spectroscopy was used to measure induced activities of $$^{137}$$Cs, $$^{136}$$Cs and monitor wires. On the basis of Westcott's convention, the $$sigma_{0}$$ and I$$_{0}$$ values were derived as 8.57$$pm$$0.25 barn, and 45.3$$pm$$3.2 barn, respectively. The $$sigma_{0}$$ obtained in the present study agreed within the limits of uncertainties with the past reported value of 8.3$$pm$$0.3 barn.

Journal Articles

Activation measurement for thermal-neutron capture cross-section of Cesium-135

Nakamura, Shoji; Kimura, Atsushi; Iwamoto, Osamu; Shibahara, Yuji*; Uehara, Akihiro*; Fujii, Toshiyuki*

KURNS Progress Report 2018, P. 106, 2019/08

Under the ImPACT project, the neutron capture cross-section measurements of Cesium-135 ($$^{135}$$Cs) among the long-lived fission products have been performed at Kyoto University. This paper reports measurements of the thermal-neutron capture cross-section of $$^{135}$$Cs at the Kyoto University Research Reactor (KUR).

Journal Articles

Measurements of thermal-neutron capture cross-section and resonance integral of neptunium-237

Nakamura, Shoji; Kitatani, Fumito; Kimura, Atsushi; Uehara, Akihiro*; Fujii, Toshiyuki*

Journal of Nuclear Science and Technology, 56(6), p.493 - 502, 2019/06

 Times Cited Count:5 Percentile:48.18(Nuclear Science & Technology)

The thermal-neutron capture cross-section($$sigma_{0}$$)and resonance integral(I$$_{0}$$) were measured for the $$^{237}$$Np(n,$$gamma$$)$$^{238}$$Np reaction by an activation method. A method with a Gadolinium filter, which is similar to the Cadmium difference method, was used to measure the $$sigma_{0}$$ with paying attention to the first resonance at 0.489 eV of $$^{237}$$Np, and a value of 0.133 eV was taken as a cut-off energy. Neptunium-237 samples were irradiated at the pneumatic tube of the Kyoto University Research Reactor in Institute for Integral Radiation and Nuclear Science, Kyoto University. Wires of Co/Al and Au/Al alloys were used as monitors to determine thermal-neutron fluxes and epi-thermal Westcott's indices at an irradiation position. A $$gamma$$-ray spectroscopy was used to measure activities of $$^{237}$$Np, $$^{238}$$Np and neutron monitors. On the basis of Westcott's convention, the $$sigma_{0}$$ and I$$_{0}$$ values were derived as 186.9$$pm$$6.2 barn, and 1009$$pm$$90 barn, respectively.

6 (Records 1-6 displayed on this page)
  • 1