Refine your search:     
Report No.
 - 
Search Results: Records 1-7 displayed on this page of 7
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Soft, skin-interfaced microfluidic systems with integrated immunoassays, fluorometric sensors, and impedance measurement capabilities

Kim, S.*; Lee, B.*; Reeder, J. T.*; Seo, S. H.*; Lee, S.-U.*; Hourlier-Fargette, A.*; Shin, J.*; Sekine, Yurina; Jeong, H.*; Oh, Y. S.*; et al.

Proceedings of the National Academy of Sciences of the United States of America, 117(45), p.27906 - 27915, 2020/11

 Times Cited Count:75 Percentile:93.23(Multidisciplinary Sciences)

In this study, we present a wireless, battery-free, skin-interfaced microfluidic system that combines lateral flow immunoassay for sweat cortisol assay, fluorometric imaging of glucose and ascorbic acid (vitamin C) assays, and digital tracking of sweat rate using electrodes that measure skin galvanic response. Systematic benchtop testing and on-body field studies on human subjects exercising in a gym environment highlight the key multifunctional features of this platform in tracking the biochemical correlates of physical stress.

Journal Articles

First neutral beam injection experiments on KSTAR tokamak

Jeong, S. H.*; Chang, D. H.*; Kim, T. S.*; In, S. R.*; Lee, K. W.*; Jin, J. T.*; Chang, D. S.*; Oh, B. H.*; Bae, Y. S.*; Kim, J. S.*; et al.

Review of Scientific Instruments, 83(2), p.02B102_1 - 02B102_3, 2012/02

 Times Cited Count:22 Percentile:68.03(Instruments & Instrumentation)

The first NB (neutral beam) injection system of the KSTAR tokamak was partially completed in 2010 with only 1/3 of its full design capability, and NB heating experiments were carried out during the 2010 KSTAR operation campaign. The ion source is composed of a JAEA bucket plasma generator and a KAERI large multi-aperture accelerator assembly. Before the beam injection experiments, characteristics of the ion source were investigated. A minimum beam divergence angle was 0.8 $$^{circ}$$. The ion species ratio was D$$^{+}$$:D$$_{2}$$$$^{+}$$:D$$_{3}$$$$^{+}$$=75:20:5. The arc efficiency is more than 1.0 A/kW. In the 2010 KSTAR campaign, the deuterium NB power of 0.7-1.5 MW was successfully injected into the KSTAR plasma with the beam energy of 70-90 keV. L-H transitions were observed within a wide range of beam powers relative to a threshold value. In every deuterium NB injection, a burst of D-D neutrons was recorded, and increases in the ion temperature and the plasma stored energy were found.

Journal Articles

Arc discharge characteristics of a long pulse ion source for the KSTAR neutral beam injector

Chang, D. H.*; Jeong, S. H.*; Jin, J. T.*; Chang, D. S.*; Kim, T. S.*; Lee, K. W.*; In, S. R.*; Oh, B. H.*; Bae, Y. S.*; Kim, J. S.*; et al.

Journal of the Korean Physical Society, 59(2), p.275 - 280, 2011/08

 Times Cited Count:3 Percentile:27.54(Physics, Multidisciplinary)

A long pulse ion source (LPIS) for the neutral beam injector (NBI) has been developed for the Korea Superconducting Tokamak Advanced Research (KSTAR) superconducting tokamak. The arc discharge characteristics of the ion source were investigated on the first KSTAR neutral beam injector (NBI-1). The ion source consists of a magnetic bucket plasma generator with multi-pole cusp fields and a set of prototype tetrode accelerators with circular apertures. Stable and efficient arc plasmas up to an arc power of 70 kW have been produced by using a constant power-mode operation of the arc power supply. The reliable operation region of the arc discharges has been investigated for various filament heating voltages, arc powers, and amounts of injected deuterium gas.

Journal Articles

Results of beam extraction performance for the KSTAR neutral beam injector

Chang, D. H.*; Jeong, S. H.*; Kim, T. S.*; Lee, K. W.*; In, S. R.*; Jin, J. T.*; Chang, D. S.*; Oh, B. H.*; Bae, Y. S.*; Kim, J. S.*; et al.

Japanese Journal of Applied Physics, 50(6), p.066302_1 - 066302_7, 2011/06

 Times Cited Count:11 Percentile:43.98(Physics, Applied)

A stable ion beam extraction of the LPIS-1 was achieved up to 85 kV/32 A for a 5 s pulse length and 80 kV/25 A for a 14 s pulse length. An optimum beam perveance of 1.15 $$mu$$perv was observed at an acceleration voltage of 60 kV. Neutralization efficiency was measured by a water-flow calorimetry (WFC) method using a calorimeter and the operation of a bending magnet. The full-energy species of ion beams were detected by using the diagnostic method of optical multichannel analyzer (OMA). An arc efficiency of the LPIS was 0.6-1.1 A/kW depending on the operating conditions of arc discharge. A neutral beam power of 1.0 MW must be sufficiently injected into the KSTAR plasmas from the LPIS-1 at a beam energy of 80 keV.

Journal Articles

Development of a plasma generator for a long pulse ion source for neutral beam injectors

Watanabe, Kazuhiro; Dairaku, Masayuki; Tobari, Hiroyuki; Kashiwagi, Mieko; Inoue, Takashi; Hanada, Masaya; Jeong, S. H.*; Chang, D. H.*; Kim, T. S.*; Kim, B. R.*; et al.

Review of Scientific Instruments, 82(6), p.063507_1 - 063507_6, 2011/06

 Times Cited Count:16 Percentile:58.97(Instruments & Instrumentation)

A long pulse plasma generator for neutral beam injectors has been developed. The plasma generator was designed to produce 65 A at 120 keV from a beam extraction area of 12 cm $$times$$ 46 cm. A type of the plasma generator is a multi-cusp plasma generator with SmCo permanent magnets. A long pulse test of the plasma generator was performed at the KSTAR NBI test stand in Korea under the Japan - Korea Fusion collaboration. It was successfully demonstrated of the long pulse operation of the plasma generator for 200 s at an arc discharge power of 70 kW which can produce 65 A beams. Plasma spatial uniformity at the beam extraction area was confirmed to be smaller than $$pm$$ 8% of the deviation from an averaged ion saturation current density. A high arc efficiency of 0.9-1.1 A/kW was obtained at the beam extraction with 73 keV, 41 A for 5 sec. From these experimental studies, a performance of this plasma generator for long pulse ion sources was confirmed.

Journal Articles

Commissioning results of the KSTAR neutral beam system

Bae, Y. S.*; Park, Y. M.*; Kim, J. S.*; Han, W. S.*; Kwak, S. W.*; Chang, Y. B.*; Park, H. T.*; Song, N. H.*; Chang, D. H.*; Jeong, S. H.*; et al.

Proceedings of 23rd IAEA Fusion Energy Conference (FEC 2010) (CD-ROM), 9 Pages, 2011/03

The neutral beam injection (NBI) system is designed to provide the ion heating and current drive for the high performance operation and long pulse operation of the Korean Superconducting Tokamak Advanced Research (KSTAR). The KSTAR NBI consists of two beam lines. Each beam line contains three ion sources of which one ion source has been designed to deliver more than 2.5 MW of deuterium neutral beam power with maximum 120-keV beam energy. Consequently, the final goal of the KSTAR NBI system aims to inject more than 14 MW of deuterium beam power with the two beam lines. According to the planned NBI system, the first NBI system is to demonstrate the beam injection from one ion source into the KSTAR tokamak plasma in 2010 campaign including the system commissioning of each components and subsystems. In this paper, the construction and the commissioning of the first NBI system with one ion source is presented.

Oral presentation

Long-pulse production of positive ion beams from JT-60U for JT-60 Super Advanced

Hanada, Masaya; Kojima, Atsushi; Akino, Noboru; Komata, Masao; Mogaki, Kazuhiko; Oh, B. H.*; Jeong, S. H.*; Chang, D. H.*; Lee, K. W.*; Bae, Y. S.*

no journal, , 

no abstracts in English

7 (Records 1-7 displayed on this page)
  • 1